Javascript must be enabled to continue!
Corneal hysteresis in patients with corneal pathologies
View through CrossRef
Abstract Purpose: To investigate the corneal hysteresis (CH), the corneal resistance factor (CRF) and the corneal compensated intraocular pressure (IOPcc) of subjects with normal corneas and with corneal pathologies with the Ocular Response Analyzer (ORA). Methods: IOP was measured using Goldmann applanation tonometry (GAT), dynamic contour tonometry (DCT) and ORA in 102 subjects with normal corneas and in patients with keratoconus (KC, n=32), Fuchs endothelial corneal dystrophy (FD, n=34) and penetrating keratoplasty (KP, n=50). Additionally central corneal thickness (CCT) and CH were quantified. Results: CH and CRF were significantly reduced in all groups with corneal pathologies in comparison to the normal group (CH: 7.7 (KC), 8.9 (KP), 7.3 (FD) versus 10.3 (N), CRF: 6.4 (KC), 9.3 (KP), 8.2 (FD) versus 10.8 (N) mmHg). High significant differences were also observed in mean IOP between the control group and the groups with corneal pathologies. There was a significant correlation between CH and CCT for normal corneas and corneas with KC and KP. Conclusions: CH and CRF are significantly decreased in patients with KC, FD and KP compared to subjects with normal corneas. Patients with corneal pathologies showed a substantial variability of mean IOP‐values evaluated by using different methods of IOP‐measurement in comparison to subjects with normal corneas suggesting that corneal properties strongly influence the validity of IOP‐measurements.
Title: Corneal hysteresis in patients with corneal pathologies
Description:
Abstract Purpose: To investigate the corneal hysteresis (CH), the corneal resistance factor (CRF) and the corneal compensated intraocular pressure (IOPcc) of subjects with normal corneas and with corneal pathologies with the Ocular Response Analyzer (ORA).
Methods: IOP was measured using Goldmann applanation tonometry (GAT), dynamic contour tonometry (DCT) and ORA in 102 subjects with normal corneas and in patients with keratoconus (KC, n=32), Fuchs endothelial corneal dystrophy (FD, n=34) and penetrating keratoplasty (KP, n=50).
Additionally central corneal thickness (CCT) and CH were quantified.
Results: CH and CRF were significantly reduced in all groups with corneal pathologies in comparison to the normal group (CH: 7.
7 (KC), 8.
9 (KP), 7.
3 (FD) versus 10.
3 (N), CRF: 6.
4 (KC), 9.
3 (KP), 8.
2 (FD) versus 10.
8 (N) mmHg).
High significant differences were also observed in mean IOP between the control group and the groups with corneal pathologies.
There was a significant correlation between CH and CCT for normal corneas and corneas with KC and KP.
Conclusions: CH and CRF are significantly decreased in patients with KC, FD and KP compared to subjects with normal corneas.
Patients with corneal pathologies showed a substantial variability of mean IOP‐values evaluated by using different methods of IOP‐measurement in comparison to subjects with normal corneas suggesting that corneal properties strongly influence the validity of IOP‐measurements.
Related Results
Surface modification treatments to enhance the performance of titanium backplate in keratoprosthesis
Surface modification treatments to enhance the performance of titanium backplate in keratoprosthesis
(English) The cornea is the outermost layer of the eye, essential for vision as it provides protection and contributes 80% of the eye’s refractive power. Its transparency and lack ...
A retrospective analysis of outcomes of an optical reconstructive surgery combined with corneal transplantation dedicated to manage complications of inflammatory diseases of the anterior chamber of the ey
A retrospective analysis of outcomes of an optical reconstructive surgery combined with corneal transplantation dedicated to manage complications of inflammatory diseases of the anterior chamber of the ey
Background: full thickness corneal transplantation or penetrating keratoplasty (PK) is the only surgical method to manage outcomes of
inflammatory diseases of the anterior eye cham...
Corneal densitometry changes in keratoconus patients after intrastromal corneal ring segments implantation
Corneal densitometry changes in keratoconus patients after intrastromal corneal ring segments implantation
BackgroundKeratoconus (KC) is an ectatic corneal disorder characterized by progressive corneal thinning with myopic astigmatism. Intrastromal corneal ring segments (ICRS) have been...
<b>Corneal Biomechanical Integrity After Femtosecond Laser-Assisted Versus Manual Incisions in Cataract Surgery: A Systematic Review</b>
<b>Corneal Biomechanical Integrity After Femtosecond Laser-Assisted Versus Manual Incisions in Cataract Surgery: A Systematic Review</b>
Background: The integrity of the clear corneal incision is fundamental to safety, wound sealing, and refractive stability in cataract surgery. Although femtosecond laser-assisted c...
Clinical Profile and Corneal Complications of Staphylococcal Blepharitis at the Philippine General Hospital
Clinical Profile and Corneal Complications of Staphylococcal Blepharitis at the Philippine General Hospital
Objectives. Staphylococcal blepharitis is a common ocular condition that can cause significant visual morbidities due to corneal complications. This study described the clinical pr...
Effects of TGFB1 and 17 B estradiol on corneal stiffness and thickness
Effects of TGFB1 and 17 B estradiol on corneal stiffness and thickness
Background: Impaired corneal stiffness and transparency are the hallmarks of some of the leading global causes of corneal blindness diseases, such as keratoconus (KCN) which is cha...
Symmetrical femtosecond laser arc incision in correcting corneal astigmatism in cataract patients
Symmetrical femtosecond laser arc incision in correcting corneal astigmatism in cataract patients
AIM: To evaluate the effect of symmetrical arc incision correcting corneal astigmatism in femtosecond laser-assisted phacoemulsification (FLACS).
METHODS: This study enrolled patie...
Correlation Between Corneal Biomechanics and Anterior Segment Parameters in Healthy Saudi Females
Correlation Between Corneal Biomechanics and Anterior Segment Parameters in Healthy Saudi Females
Abstract
Background: The ocular response analyzer (ORA) can measure corneal hysteresis (CH), corneal resistance factor (CRF), Goldmann correlated IOP (IOPg) and corneal com...

