Javascript must be enabled to continue!
Calculation Method for Uplift Capacity of Suction Caisson in Sand Considering Different Drainage Conditions
View through CrossRef
Uplift capacity of suction caissons is one of the main concerns in the design of jackets with multi-caissons supported offshore wind turbine. The uplift movement of suction caissons leads to soil stress variation and increases the difficulty to predict the uplift capacity. In this paper, a calculation method considering soil stress release and differential pressure contribution is proposed to predict the uplift capacity of caisson. Firstly, a series of numerical simulations based on the SANISAND model are conducted to study the uplift responses of suction caisson in sand, and it is verified with centrifuge test results. Considering the soil drainage condition during caisson being pulled out, the fully drained, partially drained and undrained are divided, and an equation is provided to assess differential pressure beneath the caisson lid incorporating the effects of main factors. Based on the above simulation results, a calculation method is proposed to calculate the uplift capacity of caissons. The prediction results are compared with the centrifuge model tests and previous studies, which indicate that the prediction accuracy is much improved. This proposed method contributes to the more accurate assessment of uplift capacity of suction caisson in sand.
Title: Calculation Method for Uplift Capacity of Suction Caisson in Sand Considering Different Drainage Conditions
Description:
Uplift capacity of suction caissons is one of the main concerns in the design of jackets with multi-caissons supported offshore wind turbine.
The uplift movement of suction caissons leads to soil stress variation and increases the difficulty to predict the uplift capacity.
In this paper, a calculation method considering soil stress release and differential pressure contribution is proposed to predict the uplift capacity of caisson.
Firstly, a series of numerical simulations based on the SANISAND model are conducted to study the uplift responses of suction caisson in sand, and it is verified with centrifuge test results.
Considering the soil drainage condition during caisson being pulled out, the fully drained, partially drained and undrained are divided, and an equation is provided to assess differential pressure beneath the caisson lid incorporating the effects of main factors.
Based on the above simulation results, a calculation method is proposed to calculate the uplift capacity of caissons.
The prediction results are compared with the centrifuge model tests and previous studies, which indicate that the prediction accuracy is much improved.
This proposed method contributes to the more accurate assessment of uplift capacity of suction caisson in sand.
Related Results
Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract
Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
Sand Production Management
Sand Production Management
Abstract
Sand production may be inevitable in many fields that have a relatively lower formation strength. Sand erosion and settling predictions and sand monitori...
Hemolytic characteristics of three suctioning systems for use with a newly developed cardiopulmonary bypass system
Hemolytic characteristics of three suctioning systems for use with a newly developed cardiopulmonary bypass system
Introduction: We have been developing a closed-circuit cardiopulmonary bypass (CPB) system (“Dihead CPB”) for application during coronary artery bypass grafting (CABG) and valve su...
Research on Ground Deformation Induced by Large Caisson Construction at the Zhuchong Pumping Station in Xinyang, China
Research on Ground Deformation Induced by Large Caisson Construction at the Zhuchong Pumping Station in Xinyang, China
Abstract
To explore the sidewall friction mechanism between sidewall of caisson and strata, thereby controlling the sinking of caisson project and induced surrounding subsi...
The Effects of Periodic Suction on Separated Flow in Diffuser
The Effects of Periodic Suction on Separated Flow in Diffuser
The effects of periodic suction on the separated flow are still unclear and the relevant researches are still scarce, thus this paper presents a periodic suction method to suppress...
Suction Pile Allowable Suction Pressure Envelopes Based on Soil Failure and Structural Buckling
Suction Pile Allowable Suction Pressure Envelopes Based on Soil Failure and Structural Buckling
Abstract
This study develops the allowable suction pressure envelopes using applicable industrial codes for different suction pile sizes at various penetration depth...
Development of Normal‐Suction Boundary Control Method Based on Inflow Cannula Pressure Waveform for the Undulation Pump Ventricular Assist Device
Development of Normal‐Suction Boundary Control Method Based on Inflow Cannula Pressure Waveform for the Undulation Pump Ventricular Assist Device
AbstractIt is desirable to obtain the maximum assist without suction in ventricular assist devices (VADs). However, high driving power of a VAD may cause severe ventricle suction t...
Evaluating the Sand-Trapping Efficiency of Sand Fences Using a Combination of Wind-Blown Sand Measurements and UAV Photogrammetry at Tottori Sand Dunes, Japan
Evaluating the Sand-Trapping Efficiency of Sand Fences Using a Combination of Wind-Blown Sand Measurements and UAV Photogrammetry at Tottori Sand Dunes, Japan
Fences are commonly used in coastal regions to control wind-blown sand. Sand-trapping fences and sand-stabilizing fences have been installed at the Tottori Sand Dunes, Tottori Pref...

