Study on Thermal Performance of the Small-Scale Air Conditioning with Thermoelectric Cooling Module

View through CrossRef
This work presents the COP and EER of the combined air conditioning and thermoelectric cooling systems. The small-scale air conditioning (8000 BTU/hr) with thermoelectric cooling systems is set up in the closed room (2.0*2.0*2.0 m), and free energy from the photovoltaic cell is used for the thermoelectric cooling module. The COP and EER with the thermoelectric cooling module are higher than those without the thermoelectric cooling module. It is observed that the COP and EER increase as the axial fan speeds increase. In addition, there is good agreement from the comparison, giving an average error of 3.77%. The highest COP and EER for the system with the thermoelectric cooling module are 1.71 and 5.85 for an airflow rate of 4.7 m3/s, respectively. The results can be used as guidelines for developing the thermal performance of air conditioning by combining it with the thermoelectric cooling module.
Title: Study on Thermal Performance of the Small-Scale Air Conditioning with Thermoelectric Cooling Module
Description:
This work presents the COP and EER of the combined air conditioning and thermoelectric cooling systems.
The small-scale air conditioning (8000 BTU/hr) with thermoelectric cooling systems is set up in the closed room (2.
0*2.
0*2.
0 m), and free energy from the photovoltaic cell is used for the thermoelectric cooling module.
The COP and EER with the thermoelectric cooling module are higher than those without the thermoelectric cooling module.
It is observed that the COP and EER increase as the axial fan speeds increase.
In addition, there is good agreement from the comparison, giving an average error of 3.
77%.
The highest COP and EER for the system with the thermoelectric cooling module are 1.
71 and 5.
85 for an airflow rate of 4.
7 m3/s, respectively.
The results can be used as guidelines for developing the thermal performance of air conditioning by combining it with the thermoelectric cooling module.

Related Results

Thermal Performance of the Combined Small-Scale Air Conditioning and Thermoelectric Cooling Module Driven by Solar Cells
Thermal Performance of the Combined Small-Scale Air Conditioning and Thermoelectric Cooling Module Driven by Solar Cells
This work's objective is to present the COP and EER of the combined air conditioning and thermoelectric cooling systems. The small-scale air conditioning (8000 BTU/hr) wit...
RELATIONSHIP OF NON-EQUILIBRIUM THERMODYNAMICS IN THE HETEROGENEOUS PERMEABLE THERMOELEMENTS
RELATIONSHIP OF NON-EQUILIBRIUM THERMODYNAMICS IN THE HETEROGENEOUS PERMEABLE THERMOELEMENTS
A significant number of thermoelectric processes are described with fundamental law of thermodynamics. This paper describes thermoelectric processes in the permea...
High Thermoelectric Cooling Performance of Junction Thermoelectric Transistors
High Thermoelectric Cooling Performance of Junction Thermoelectric Transistors
To achieve high performance thermoelectric materials and devices, thermoelectric transistors, which integrate thermoelectric effects with transistor technology, represent a promisi...
High Thermoelectric Cooling Performance of Junction Thermoelectric Transistors
High Thermoelectric Cooling Performance of Junction Thermoelectric Transistors
To achieve high performance thermoelectric materials and devices, thermoelectric transistors, which integrate thermoelectric effects with transistor technology, represent a promisi...
ANALISIS PERTIMBANGAN MAHKAMAH AGUNG DALAM MENGABULKAN KASASI TERDAKWA (STUDI PUTUSAN NOMOR 2959/K/PID.SUS/2022)
ANALISIS PERTIMBANGAN MAHKAMAH AGUNG DALAM MENGABULKAN KASASI TERDAKWA (STUDI PUTUSAN NOMOR 2959/K/PID.SUS/2022)
<p><em><span class="markedContent"><span style="left: calc(var(--scale-factor)*195.53px); top: calc(var(--scale-factor)*496.87px); font-size: calc(var(--scale-...
A review on solar photovoltaic-powered thermoelectric coolers, performance enhancements, and recent advances
A review on solar photovoltaic-powered thermoelectric coolers, performance enhancements, and recent advances
Abstract The average global temperature has increased by approximately 0.7 °C since the last century. If the current trend continues, the temperature may further increase by 1.4 – ...
Theoretical and Experimental Investigations of Solar-Thermoelectric Air-Conditioning System for Remote Applications
Theoretical and Experimental Investigations of Solar-Thermoelectric Air-Conditioning System for Remote Applications
In this paper, we have designed and constructed a low cost solar-thermoelectric (TE) air-conditioning system for people in remote areas where electricity is still in short supply. ...
Thermal Effects in High Compactness CEA Stack
Thermal Effects in High Compactness CEA Stack