Thermal Performance of the Combined Small-Scale Air Conditioning and Thermoelectric Cooling Module Driven by Solar Cells
View through CrossRef
This work's objective is to present the COP and EER of the combined air conditioning and thermoelectric cooling systems. The small-scale air conditioning (8000 BTU/hr) with thermoelectric cooling systems are set up in the closed room (2.0*2.0*2.0 m), which free energy from the photovoltaic cell is used for the thermoelectric cooling module. The COP and EER with the thermoelectric cooling module are higher than those without the thermoelectric cooling module. It is observed that the COP and EER increase as the axial fan speeds increase. In addition, there is good agreement from the comparison and gives an average error of 3.77%. The highest COP and EER for the system with the thermoelectric cooling module are 1.71 and 5.85 for airflow rate of 4.7 m 3 /s, respectively. The results can be used as guidelines for developing the thermal performance of air conditioning by combining it with the thermoelectric cooling module.
Title: Thermal Performance of the Combined Small-Scale Air Conditioning and Thermoelectric Cooling Module Driven by Solar Cells
Description:
This work's objective is to present the COP and EER of the combined air conditioning and thermoelectric cooling systems.
The small-scale air conditioning (8000 BTU/hr) with thermoelectric cooling systems are set up in the closed room (2.
0*2.
0*2.
0 m), which free energy from the photovoltaic cell is used for the thermoelectric cooling module.
The COP and EER with the thermoelectric cooling module are higher than those without the thermoelectric cooling module.
It is observed that the COP and EER increase as the axial fan speeds increase.
In addition, there is good agreement from the comparison and gives an average error of 3.
77%.
The highest COP and EER for the system with the thermoelectric cooling module are 1.
71 and 5.
85 for airflow rate of 4.
7 m 3 /s, respectively.
The results can be used as guidelines for developing the thermal performance of air conditioning by combining it with the thermoelectric cooling module.
Related Results
Study on Thermal Performance of the Small-Scale Air Conditioning with Thermoelectric Cooling Module
Study on Thermal Performance of the Small-Scale Air Conditioning with Thermoelectric Cooling Module
This work presents the COP and EER of the combined air conditioning and thermoelectric cooling systems. The small-scale air conditioning (8000 BTU/hr) with thermoelectric cooling s...
A review on solar photovoltaic-powered thermoelectric coolers, performance enhancements, and recent advances
A review on solar photovoltaic-powered thermoelectric coolers, performance enhancements, and recent advances
Abstract
The average global temperature has increased by approximately 0.7 °C since the last century. If the current trend continues, the temperature may further increase by 1.4 – ...
RELATIONSHIP OF NON-EQUILIBRIUM THERMODYNAMICS IN THE HETEROGENEOUS PERMEABLE THERMOELEMENTS
RELATIONSHIP OF NON-EQUILIBRIUM THERMODYNAMICS IN THE HETEROGENEOUS PERMEABLE THERMOELEMENTS
A significant number of thermoelectric processes are described with fundamental law of thermodynamics. This paper describes thermoelectric processes in the permea...
Theoretical and Experimental Investigations of Solar-Thermoelectric Air-Conditioning System for Remote Applications
Theoretical and Experimental Investigations of Solar-Thermoelectric Air-Conditioning System for Remote Applications
In this paper, we have designed and constructed a low cost solar-thermoelectric (TE) air-conditioning system for people in remote areas where electricity is still in short supply. ...
High Thermoelectric Cooling Performance of Junction Thermoelectric Transistors
High Thermoelectric Cooling Performance of Junction Thermoelectric Transistors
To achieve high performance thermoelectric materials and devices, thermoelectric transistors, which integrate thermoelectric effects with transistor technology, represent a promisi...
High Thermoelectric Cooling Performance of Junction Thermoelectric Transistors
High Thermoelectric Cooling Performance of Junction Thermoelectric Transistors
To achieve high performance thermoelectric materials and devices, thermoelectric transistors, which integrate thermoelectric effects with transistor technology, represent a promisi...
ANALISIS PERTIMBANGAN MAHKAMAH AGUNG DALAM MENGABULKAN KASASI TERDAKWA (STUDI PUTUSAN NOMOR 2959/K/PID.SUS/2022)
ANALISIS PERTIMBANGAN MAHKAMAH AGUNG DALAM MENGABULKAN KASASI TERDAKWA (STUDI PUTUSAN NOMOR 2959/K/PID.SUS/2022)
<p><em><span class="markedContent"><span style="left: calc(var(--scale-factor)*195.53px); top: calc(var(--scale-factor)*496.87px); font-size: calc(var(--scale-...
Thermal Effects in High Compactness CEA Stack
Thermal Effects in High Compactness CEA Stack
Thermal management is a pivotal aspect of stack durability and system operability. Consequently, understanding the thermal mapping within a stack based on its operating conditions ...