Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Discrimination of Transformer Inrush Currents and Internal Fault Currents Using Extended Kalman Filter Algorithm (EKF)

View through CrossRef
The discrimination of inrush currents and internal fault currents in transformers is an important feature of a transformer protection scheme. The harmonic current restrained feature is used in conventional differential relay protection of transformers. A literature survey shows that the discrimination between the inrush currents and internal fault currents is still an area that is open to research. In this paper, the classification of internal fault currents and magnetic inrush currents in the transformer is performed by using an extended Kalman filter (EKF) algorithm. When a transformer is energized under normal conditions, the EKF estimates the primary side winding current and, hence, the absolute residual signal (ARS) value is zero. The ARS value will not be equal to zero for internal fault and inrush phenomena conditions; hence, the EKF algorithm will be used for discriminating the internal faults and inrush faults by keeping the threshold level to the ARS value. The simulation results are compared with the theoretical analysis under various conditions. It is also observed that the detection time of internal faults decreases with the severity of the fault. The results of various test cases using the EKF algorithm are presented. This scheme provides fast protection of the transformer for severe faults.
Title: Discrimination of Transformer Inrush Currents and Internal Fault Currents Using Extended Kalman Filter Algorithm (EKF)
Description:
The discrimination of inrush currents and internal fault currents in transformers is an important feature of a transformer protection scheme.
The harmonic current restrained feature is used in conventional differential relay protection of transformers.
A literature survey shows that the discrimination between the inrush currents and internal fault currents is still an area that is open to research.
In this paper, the classification of internal fault currents and magnetic inrush currents in the transformer is performed by using an extended Kalman filter (EKF) algorithm.
When a transformer is energized under normal conditions, the EKF estimates the primary side winding current and, hence, the absolute residual signal (ARS) value is zero.
The ARS value will not be equal to zero for internal fault and inrush phenomena conditions; hence, the EKF algorithm will be used for discriminating the internal faults and inrush faults by keeping the threshold level to the ARS value.
The simulation results are compared with the theoretical analysis under various conditions.
It is also observed that the detection time of internal faults decreases with the severity of the fault.
The results of various test cases using the EKF algorithm are presented.
This scheme provides fast protection of the transformer for severe faults.

Related Results

Integration Techniques of Fault Detection and Isolation Using Interval Observers
Integration Techniques of Fault Detection and Isolation Using Interval Observers
An interval observer has been illustrated to be a suitable approach to detect and isolate faults affecting complex dynamical industrial systems. Concerning fault detection, interv...
Improvement of operation of power transformer protection system during sympathetic inrush current phenomena using fault current limiter
Improvement of operation of power transformer protection system during sympathetic inrush current phenomena using fault current limiter
Power transformer protection has a high sensitivity due to its important role in power systems. Various factors such as inrush and sympathetic inrush currents may result in the ina...
Second Order Extended Ensemble Filter for Non-linear Filtering
Second Order Extended Ensemble Filter for Non-linear Filtering
Whenever the state of a system must be estimated from noisy information, a state estimator is employed to fuse the data with the model to produce an accurate estimate of the state....
A Water‐Rock Coupled Model for Fault Water Inrush: A Case Study in Xiaochang Coal Mine, China
A Water‐Rock Coupled Model for Fault Water Inrush: A Case Study in Xiaochang Coal Mine, China
Water inrush disasters in mining frequently occur under the influence of confined water‐bearing fault zones. Therefore, investigating the fault water inrush mechanism is necessary ...
Assessment and Mitigation Studies of Voltage Sags during Sympathetic Inrush Current
Assessment and Mitigation Studies of Voltage Sags during Sympathetic Inrush Current
The system voltage may be negatively impacted by the transformer’s energisation which draws a large value of magnetising inrush current for a few seconds. During the transformer’s ...
Automatic Load Sharing of Transformer
Automatic Load Sharing of Transformer
Transformer plays a major role in the power system. It works 24 hours a day and provides power to the load. The transformer is excessive full, its windings are overheated which lea...
Adaptative high-gain extended Kalman filter and applications
Adaptative high-gain extended Kalman filter and applications
Le filtre de Kalman étendu à grand-gain adaptatif et ses applications Le travail porte sur la problématique de l’observation des systèmes — la reconstruction de l’é...

Back to Top