Javascript must be enabled to continue!
Three-dimensional cardiac CT integration for procedural guidance in LVOT-PVC ablation: a targeted clinical approach based on electrocardiographic and patient-specific criteria
View through CrossRef
Abstract
Introduction
Ablation of ventricular premature complexes (PVCs) originating in the ventricular outflow tract (PVCs-OT) is challenging, particularly at left ventricular outflow tract (LVOT) sites. Although intracardiac ultrasound can aid procedural guidance, it involves additional vascular access, increased manipulation, and higher costs. Integrating pre-procedural three-dimensional (3D) computed tomography (CT) reconstructions offers an alternative to enhance PVC-LVOT ablation.
Purpose
To evaluate the efficacy and safety of incorporating 3D CT imaging in PVC-OT ablation guided by electrocardiographic and patient-specific criteria, aiming to optimise procedural success and minimise risks.
Methods
Patients referred for PVCs-OT ablation from January 2021 onward were included. Our pre-ablation protocol for patients with PVCs showing transition ≤ V3 includes CT scanning within 24 hours of the procedure. Ablation was performed through single femoral access using only an ablation catheter (SmartTouch, Biosense). Retroaortic electroanatomic mapping was applied in cases with transition <v3,<50 years). Ablation was delivered at 40W and an f-index of 450-500, with a minimum 1 cm distance from coronary arteries, as determined by CT. Success at 1-year follow-up was defined as >80% PVC reduction on Holter.
Results
Seventy-two patients were included, 64% with transition ≤ V3. Pre-procedural CT was performed in 68% of cases. The LVOT was the most frequent site of origin (63%). Acute success was achieved in 96% of cases, with 85% success at 1-year follow-up (Table 1). Mean procedure and fluoroscopy times were 66 ± 33 minutes and 2.3 ± 3.8 minutes, respectively. No procedural or vascular complications were noted. In transition ≤ V3 cases, left-sided origins were found in 87%, with a mean procedure time of 77 ± 31 minutes and fluoroscopy of 3 ± 4 minutes. Acute and 1-year success rates were 93% and 82%, respectively. All patients with transition at V3 and right-sided origins did not .
Conclusions
The integration of 3D CT in PVCs-OT ablation, guided by electrocardiographic and clinical criteria, demonstrates high efficacy and safety in patients with suspected left-sided PVC origins, providing a streamlined and effective approach to LVOT-PVC ablation.PVC ablation approach. Table 1:Procedural time/success rate
Oxford University Press (OUP)
Title: Three-dimensional cardiac CT integration for procedural guidance in LVOT-PVC ablation: a targeted clinical approach based on electrocardiographic and patient-specific criteria
Description:
Abstract
Introduction
Ablation of ventricular premature complexes (PVCs) originating in the ventricular outflow tract (PVCs-OT) is challenging, particularly at left ventricular outflow tract (LVOT) sites.
Although intracardiac ultrasound can aid procedural guidance, it involves additional vascular access, increased manipulation, and higher costs.
Integrating pre-procedural three-dimensional (3D) computed tomography (CT) reconstructions offers an alternative to enhance PVC-LVOT ablation.
Purpose
To evaluate the efficacy and safety of incorporating 3D CT imaging in PVC-OT ablation guided by electrocardiographic and patient-specific criteria, aiming to optimise procedural success and minimise risks.
Methods
Patients referred for PVCs-OT ablation from January 2021 onward were included.
Our pre-ablation protocol for patients with PVCs showing transition ≤ V3 includes CT scanning within 24 hours of the procedure.
Ablation was performed through single femoral access using only an ablation catheter (SmartTouch, Biosense).
Retroaortic electroanatomic mapping was applied in cases with transition <v3,<50 years).
Ablation was delivered at 40W and an f-index of 450-500, with a minimum 1 cm distance from coronary arteries, as determined by CT.
Success at 1-year follow-up was defined as >80% PVC reduction on Holter.
Results
Seventy-two patients were included, 64% with transition ≤ V3.
Pre-procedural CT was performed in 68% of cases.
The LVOT was the most frequent site of origin (63%).
Acute success was achieved in 96% of cases, with 85% success at 1-year follow-up (Table 1).
Mean procedure and fluoroscopy times were 66 ± 33 minutes and 2.
3 ± 3.
8 minutes, respectively.
No procedural or vascular complications were noted.
In transition ≤ V3 cases, left-sided origins were found in 87%, with a mean procedure time of 77 ± 31 minutes and fluoroscopy of 3 ± 4 minutes.
Acute and 1-year success rates were 93% and 82%, respectively.
All patients with transition at V3 and right-sided origins did not .
Conclusions
The integration of 3D CT in PVCs-OT ablation, guided by electrocardiographic and clinical criteria, demonstrates high efficacy and safety in patients with suspected left-sided PVC origins, providing a streamlined and effective approach to LVOT-PVC ablation.
PVC ablation approach.
Table 1:Procedural time/success rate.
Related Results
Autonomy on Trial
Autonomy on Trial
Photo by CHUTTERSNAP on Unsplash
Abstract
This paper critically examines how US bioethics and health law conceptualize patient autonomy, contrasting the rights-based, individualist...
E-071 Organization of a Neurointerventional Fellowship Curriculum
E-071 Organization of a Neurointerventional Fellowship Curriculum
Introduction
The field of Neurointervention has attracted some of the very best physicians across the world. Given the interdisciplinary nature of this specialty,...
Aortic valve morphology and the double envelope phenomenon in continuous Doppler echocardiography of aortic stenosis: a computerized model
Aortic valve morphology and the double envelope phenomenon in continuous Doppler echocardiography of aortic stenosis: a computerized model
Abstract
Introduction
Visualization of a double envelope (DE) is a relatively common issue in aortic transvalvular continuous-wa...
C64. New Onset PVC Bigeminy Post Covid-19 Infection: Another Covid-Cardiac Related Problem
C64. New Onset PVC Bigeminy Post Covid-19 Infection: Another Covid-Cardiac Related Problem
Abstract
Background
Covid-19 is an infectious disease caused by a newly discovered coronavirus that caused acute severe respirat...
C64. New Onset PVC Bigeminy Post Covid-19 Infection: Another Covid-Cardiac Related Problem
C64. New Onset PVC Bigeminy Post Covid-19 Infection: Another Covid-Cardiac Related Problem
Abstract
Background
Covid-19 is an infectious disease caused by a newly discovered coronavirus that caused acute severe respirat...
Microwave Ablation with or Without Chemotherapy in Management of Non-Small Cell Lung Cancer: A Systematic Review
Microwave Ablation with or Without Chemotherapy in Management of Non-Small Cell Lung Cancer: A Systematic Review
Abstract
Introduction
Microwave ablation (MWA) has emerged as a minimally invasive treatment for patients with inoperable non-small cell lung cancer (NSCLC). However, whether it i...
Left Ventricular Outflow Tract Velocity Time Integral in Hospitalized Heart Failure with Preserved Ejection Fraction
Left Ventricular Outflow Tract Velocity Time Integral in Hospitalized Heart Failure with Preserved Ejection Fraction
Abstract
Aims
The prognostic implication of left ventricular outflow tract velocity time integral (LVOT-VTI) on admission...
Imaging-derived tissue visualization guides catheter ablation of premature ventricular contractions
Imaging-derived tissue visualization guides catheter ablation of premature ventricular contractions
Abstract
Background
The presence of myocardial scarring is associated with worse outcomes after catheter ablation of premature v...