Four‐dimensional volume‐rendered imaging of the fetal ventricular outflow tracts and great arteries using inversion mode for detection of congenital heart disease
View through CrossRef
AbstractAim: Using four‐dimensional (4D) sonography with an inversion mode, we evaluated fetal ventricular outflow tracts and great vessels for the detection of congenital heart disease.Methods: Volume datasets of the fetal heart were acquired with spatiotemporal image correlation (STIC), which uses automated transverse and longitudinal sweeps of the anterior chest wall. A total of 12 normal fetuses and seven fetuses with congenital heart disease (one case of double‐outlet right ventricle, one case of tetralogy of Fallot, one case of transposition of the great arteries, one case of hypoplastic pulmonary artery with a large ventricular septal defect, and three cases of hypoplastic left heart syndrome) at 16–37 weeks of gestation were studied using transabdominal 4D sonography with an inversion mode. 4D inversion mode images of great arteries were evaluated.Results: 4D ultrasound with an inversion mode demonstrated real‐time 3D angiographic features of fetal cardiac outflow tracts in both normal and abnormal fetal hearts. This modality facilitated visualization of the relationships, size, and course of the outflow tracts, thus helping the examiner to more effectively understand the spatial relationships between the vessels. In normal fetal hearts, it was clearly shown that the pulmonary artery crosses in front of the aorta. In the three cases of hypoplastic left heart syndrome, an extremely small ascending aorta was evident. In the one case of tetralogy of Fallot, a relatively small pulmonary artery was noted. In the one case of hypoplastic pulmonary artery with a large ventricular septal defect, a markedly small main pulmonary artery was depicted. In the case of transposition of the great arteries, the vessels left the ventricles parallel to each other. In the case of double‐outlet right ventricle, great arteries leaving the right ventricle in parallel were shown.Conclusion: 4D ultrasound in the inversion mode provides a means of evaluating fetal cardiac outflow tracts in 3D in real time. This technique may assist in the evaluation of spatial relationships between the great vessels and both ventricles, and the difference in the size of great vessels. Moreover, the inversion mode images should be more readily discernible than those obtained by conventional ultrasonography. 4D ultrasound in the inversion mode may be an important modality in future fetal cardiac research and in the evaluation of fetal congenital heart disease.
Title: Four‐dimensional volume‐rendered imaging of the fetal ventricular outflow tracts and great arteries using inversion mode for detection of congenital heart disease
Description:
AbstractAim: Using four‐dimensional (4D) sonography with an inversion mode, we evaluated fetal ventricular outflow tracts and great vessels for the detection of congenital heart disease.
Methods: Volume datasets of the fetal heart were acquired with spatiotemporal image correlation (STIC), which uses automated transverse and longitudinal sweeps of the anterior chest wall.
A total of 12 normal fetuses and seven fetuses with congenital heart disease (one case of double‐outlet right ventricle, one case of tetralogy of Fallot, one case of transposition of the great arteries, one case of hypoplastic pulmonary artery with a large ventricular septal defect, and three cases of hypoplastic left heart syndrome) at 16–37 weeks of gestation were studied using transabdominal 4D sonography with an inversion mode.
4D inversion mode images of great arteries were evaluated.
Results: 4D ultrasound with an inversion mode demonstrated real‐time 3D angiographic features of fetal cardiac outflow tracts in both normal and abnormal fetal hearts.
This modality facilitated visualization of the relationships, size, and course of the outflow tracts, thus helping the examiner to more effectively understand the spatial relationships between the vessels.
In normal fetal hearts, it was clearly shown that the pulmonary artery crosses in front of the aorta.
In the three cases of hypoplastic left heart syndrome, an extremely small ascending aorta was evident.
In the one case of tetralogy of Fallot, a relatively small pulmonary artery was noted.
In the one case of hypoplastic pulmonary artery with a large ventricular septal defect, a markedly small main pulmonary artery was depicted.
In the case of transposition of the great arteries, the vessels left the ventricles parallel to each other.
In the case of double‐outlet right ventricle, great arteries leaving the right ventricle in parallel were shown.
Conclusion: 4D ultrasound in the inversion mode provides a means of evaluating fetal cardiac outflow tracts in 3D in real time.
This technique may assist in the evaluation of spatial relationships between the great vessels and both ventricles, and the difference in the size of great vessels.
Moreover, the inversion mode images should be more readily discernible than those obtained by conventional ultrasonography.
4D ultrasound in the inversion mode may be an important modality in future fetal cardiac research and in the evaluation of fetal congenital heart disease.
Related Results
Maternal Micronutrients, Environmental Exposures, and Congenital Heart Disease: Expanding Opportunities for Prevention
Maternal Micronutrients, Environmental Exposures, and Congenital Heart Disease: Expanding Opportunities for Prevention
Congenital heart disease (CHD) remains the most common congenital anomaly worldwide and a leading cause of infant morbidity and mortality. Despite remarkable advances in prenatal d...
GENETIC PERSPECTIVE OF THE CONGENITAL HEART DISEASE
GENETIC PERSPECTIVE OF THE CONGENITAL HEART DISEASE
Congenital heart diseases (CHDs) are the structural abnormalities that may occur in the heart, greater veins and arteries or may include the septum between the ventricles and atria...
Heart failure: the influence of different types on the main arteries kinetics
Heart failure: the influence of different types on the main arteries kinetics
Abstract
Funding Acknowledgements
Type of funding sources: None.
Nowadays the term "heart-vessels failure" doe...
Four‐dimensional sonography with B‐flow imaging and spatiotemporal image correlation for visualization of the fetal heart
Four‐dimensional sonography with B‐flow imaging and spatiotemporal image correlation for visualization of the fetal heart
AbstractPurpose.To use B‐flow imaging with 4‐dimensional (4D) sonography and spatiotemporal image correlation (STIC) in the evaluation of normal fetal heart and congenital heart di...
Novel Application of Four‐Dimensional Sonography with B‐Flow Imaging and Spatiotemporal Image Correlation in the Assessment of Fetal Congenital Heart Defects
Novel Application of Four‐Dimensional Sonography with B‐Flow Imaging and Spatiotemporal Image Correlation in the Assessment of Fetal Congenital Heart Defects
Aims: To evaluate the role of four‐dimensional (4D) ultrasound with B‐flow imaging and spatiotemporal image correlation (STIC) in the evaluation of normal fetal heart and congenita...
e0517 Forearm arteries with ultrasound for percutaneous coronary procedures
e0517 Forearm arteries with ultrasound for percutaneous coronary procedures
Background
The radial artery has become a widely used approach for coronary angiography and intervention in patients, and the ulnar artery is another approach for...
Global Policy and Practice for Intrauterine Fetal Resuscitation During Fetal Surgery for Open Spina Bifida Repair
Global Policy and Practice for Intrauterine Fetal Resuscitation During Fetal Surgery for Open Spina Bifida Repair
ImportanceGlobally accepted recommendations suggest that a woman should be between 19 weeks and 25 weeks plus 6 days of pregnancy to be considered eligible for fetal closure of ope...
Correlation Between the Ventricular Electrogram Amplitude in Sinus Rhythm and in Ventricular Fibrillation
Correlation Between the Ventricular Electrogram Amplitude in Sinus Rhythm and in Ventricular Fibrillation
During testing of implantable defibrillators, ability to sense ventricular fibrillation is assessed by observing electrograms and the emitted ECG interpretation channel during indu...