Four‐dimensional sonography with B‐flow imaging and spatiotemporal image correlation for visualization of the fetal heart
View through CrossRef
AbstractPurpose.To use B‐flow imaging with 4‐dimensional (4D) sonography and spatiotemporal image correlation (STIC) in the evaluation of normal fetal heart and congenital heart disease during pregnancy.Method.Volume data sets of the fetal heart were acquired with automated transverse and longitudinal sweeps of the anterior chest wall. We studied 13 normal fetuses and 2 fetuses with congenital heart disease (1 double‐outlet right ventricle and 1 hypoplastic left heart syndrome) at gestation ages ranging from 13 to 39 weeks using transabdominal 4D B‐flow sonography with STIC (4D BF‐STIC).Results.4D BF‐STIC demonstrated dynamic angiographic features in both normal and abnormal fetal hearts. 4D BF‐STIC images could not be obtained in 2 normal fetuses at 18.1 and 33.1 weeks because of the high fetal heart rate and inappropriate fetal position. In normal fetal heart, characteristic hemodynamic changes in both atria and ventricles were clearly demonstrated in systole and diastole. 4D BF‐STIC also allowed visualization of the relationship, size, and course of the outflow tracts, thus helping the examiner to better understand the relationships between the vessels. In a case of hypoplastic left heart syndrome, dramatic hemodynamic changes including the right atrium, right ventricle, and pulmonary artery were evident. In a case of double‐outlet right ventricle with ventricular septal defect, left‐to‐right shunt flow through a ventricular septal defect was clearly shown, as were great arteries originating in parallel from the right ventricle.Conclusion.4D BF‐STIC provides a means of real‐time 3‐dimensional evaluation of fetal intracardiac and extracardiac hemodynamics in the second and third trimesters. This novel technique assists in the evaluation of fetal cardiac hemodynamics and may play an important role in future fetal cardiac research and in the evaluation of congenital heart disease in the fetus. © 2008 Wiley Periodicals, Inc. J Clin Ultrasound, 2008.
Title: Four‐dimensional sonography with B‐flow imaging and spatiotemporal image correlation for visualization of the fetal heart
Description:
AbstractPurpose.
To use B‐flow imaging with 4‐dimensional (4D) sonography and spatiotemporal image correlation (STIC) in the evaluation of normal fetal heart and congenital heart disease during pregnancy.
Method.
Volume data sets of the fetal heart were acquired with automated transverse and longitudinal sweeps of the anterior chest wall.
We studied 13 normal fetuses and 2 fetuses with congenital heart disease (1 double‐outlet right ventricle and 1 hypoplastic left heart syndrome) at gestation ages ranging from 13 to 39 weeks using transabdominal 4D B‐flow sonography with STIC (4D BF‐STIC).
Results.
4D BF‐STIC demonstrated dynamic angiographic features in both normal and abnormal fetal hearts.
4D BF‐STIC images could not be obtained in 2 normal fetuses at 18.
1 and 33.
1 weeks because of the high fetal heart rate and inappropriate fetal position.
In normal fetal heart, characteristic hemodynamic changes in both atria and ventricles were clearly demonstrated in systole and diastole.
4D BF‐STIC also allowed visualization of the relationship, size, and course of the outflow tracts, thus helping the examiner to better understand the relationships between the vessels.
In a case of hypoplastic left heart syndrome, dramatic hemodynamic changes including the right atrium, right ventricle, and pulmonary artery were evident.
In a case of double‐outlet right ventricle with ventricular septal defect, left‐to‐right shunt flow through a ventricular septal defect was clearly shown, as were great arteries originating in parallel from the right ventricle.
Conclusion.
4D BF‐STIC provides a means of real‐time 3‐dimensional evaluation of fetal intracardiac and extracardiac hemodynamics in the second and third trimesters.
This novel technique assists in the evaluation of fetal cardiac hemodynamics and may play an important role in future fetal cardiac research and in the evaluation of congenital heart disease in the fetus.
© 2008 Wiley Periodicals, Inc.
J Clin Ultrasound, 2008.
Related Results
Novel Application of Four‐Dimensional Sonography with B‐Flow Imaging and Spatiotemporal Image Correlation in the Assessment of Fetal Congenital Heart Defects
Novel Application of Four‐Dimensional Sonography with B‐Flow Imaging and Spatiotemporal Image Correlation in the Assessment of Fetal Congenital Heart Defects
Aims: To evaluate the role of four‐dimensional (4D) ultrasound with B‐flow imaging and spatiotemporal image correlation (STIC) in the evaluation of normal fetal heart and congenita...
Global Policy and Practice for Intrauterine Fetal Resuscitation During Fetal Surgery for Open Spina Bifida Repair
Global Policy and Practice for Intrauterine Fetal Resuscitation During Fetal Surgery for Open Spina Bifida Repair
ImportanceGlobally accepted recommendations suggest that a woman should be between 19 weeks and 25 weeks plus 6 days of pregnancy to be considered eligible for fetal closure of ope...
Four‐dimensional volume‐rendered imaging of the fetal ventricular outflow tracts and great arteries using inversion mode for detection of congenital heart disease
Four‐dimensional volume‐rendered imaging of the fetal ventricular outflow tracts and great arteries using inversion mode for detection of congenital heart disease
AbstractAim: Using four‐dimensional (4D) sonography with an inversion mode, we evaluated fetal ventricular outflow tracts and great vessels for the detection of congenital heart d...
Determination of fetal weight by ultrasonographic evaluation of fetal mid-thigh soft-tissue thickness in late third trimester
Determination of fetal weight by ultrasonographic evaluation of fetal mid-thigh soft-tissue thickness in late third trimester
Background: Estimation of fetal weight is of utmost importance in the planning and management of uneventful labor. This study was done to compare the estimated fetal weight determi...
Does normal fetal brain imaging in monochorionic twins following co-twin fetal demise eliminate the risk of adverse neurodevelopmental outcome?
Does normal fetal brain imaging in monochorionic twins following co-twin fetal demise eliminate the risk of adverse neurodevelopmental outcome?
Abstract
Objective
To assess the residual risk of long-term adverse neurodevelopmental outcomes in monochorionic twins fo...
Ovine fetal metabolism during norepinephrine infusion
Ovine fetal metabolism during norepinephrine infusion
Although stress in fetal life not only increases fetal catecholamine concentration but also decreases fetal growth, there have been few studies that define the specific role of cat...
Fetal Arrhythmias: A Clinical Review
Fetal Arrhythmias: A Clinical Review
ABSTRACT
Fetal rhythm abnormalities occur in 2% of pregnancies. They are usually identified by the obstetrician or midwifes after 20 weeks. There are four different methods used to...
Feasibility of energy-resolved angiography
Feasibility of energy-resolved angiography
<p dir="ltr">Cardiovascular disease (CVD) is the leading cause of death globally, with coronary heart disease being one of the most common types of CVD. Two-dimensional x-ray...