Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Qualitative algorithm for microwave colonoscopy

View through CrossRef
(English) This thesis develops and validates an innovative algorithm for colorectal cancer (CRC) detection using microwaves, integrating it into endoscopic procedures. Validation includes ex-vivo, in-vivo, and clinical trials. The algorithm enhances polyp detection by exploiting dielectric contrast between healthy and cancerous tissues, addressing colonoscopy limitations. It normalizes signals, calibrates artifacts, reconstructs images, and applies automatic detection to improve sensitivity and specificity. Key calibration strategies include First Frame Subtraction, Similar Frame Subtraction, Antenna-Pair Subtraction, and Previous Frames Averaging to isolate polyp scattering. Automatic detection methods, such as Exponential Smoothing and Target-to-Clutter Ratio Thresholding, enable polyp identification regardless of anatomy. The algorithm undergoes extensive preclinical testing with phantom models, ex-vivo tissues, and in-vivo pig trials, evaluating detection accuracy through sensitivity, specificity, and mismatch metrics. A pilot clinical trial validates real-world performance. Optimization involves refining a phantom model to simulate colonoscopy conditions and tuning algorithm parameters for a second clinical trial. These advancements position microwave-based detection as a promising CRC screening alternative. The research demonstrates the potential of microwave imaging to improve diagnostics, offering real-time, automated polyp detection with meaningful clinical impact. (Català) Aquesta tesi desenvolupa i valida un algoritme innovador per a la detecció del càncer colorectal (CRC) mitjançant microones, integrant-lo en endoscòpies. La validació inclou proves ex-vivo, in-vivo i assaigs clínics. L’algoritme millora la detecció de pòlips aprofitant el contrast dielèctric entre teixits sans i cancerosos, superant les limitacions de la colonoscòpia. Per fer-ho, normalitza senyals, calibra artefactes, reconstrueix imatges i aplica detecció automàtica per augmentar la sensibilitat i especificitat. Les estratègies de calibratge inclouen First Frame Subtraction, Similar Frame Subtraction, Antenna-Pair Subtraction i Previous Frames Averaging per aïllar la dispersió dels pòlips. Els mètodes Exponential Smoothing i Target-to-Clutter Ratio Thresholding permeten la detecció automàtica independentment de l’anatomia. L’algoritme es prova en estudis preclínics amb models fantasma, teixits ex-vivo i assaigs in-vivo en porcs, avaluant sensibilitat, especificitat i desajust. Un assaig clínic pilot valida la seva aplicació en endoscòpies reals. L’optimització se centra en desenvolupar un model físic al laboratori que reprodueixi millor una colonoscòpia i ajustar els paràmetres per a un segon assaig clínic. Aquests avenços posicionen la detecció amb microones com una alternativa prometedora per al cribratge del CRC, millorant el diagnòstic en temps real i l’eficiència sanitària. (Español) Esta tesis desarrolla y valida un algoritmo innovador para la detección del cáncer colorrectal (CRC) mediante microondas, integrándolo en endoscopias. Su validación incluye pruebas ex-vivo, in-vivo y ensayos clínicos. El algoritmo mejora la detección de pólipos aprovechando la diferencia dieléctrica entre tejidos sanos y cancerosos, superando las limitaciones de la colonoscopia. Para ello, normaliza señales, calibra artefactos, reconstruye imágenes y aplica detección automática para aumentar sensibilidad y especificidad. Las estrategias de calibración incluyen First Frame Subtraction, Similar Frame Subtraction, Antenna-Pair Subtraction y Previous Frames Averaging para aislar la dispersión de pólipos. Métodos avanzados como Exponential Smoothing y Target-to-Clutter Ratio Thresholding permiten la detección automática independientemente de la anatomía. El algoritmo se evalúa en estudios preclínicos con modelos fantoma, tejidos ex-vivo y ensayos in-vivo en cerdos, midiendo sensibilidad, especificidad y desajuste. Un ensayo clínico piloto valida su uso en endoscopias reales. La optimización se centra en mejorar un modelo fantoma que simule con precisión una colonoscopia y en ajustar parámetros para un segundo ensayo clínico. Estos avances posicionan la detección con microondas como una alternativa prometedora para el cribado del CRC, contribuyendo al diagnóstico en tiempo real y mejorando la eficiencia en salud.
Universitat Politècnica de Catalunya
Title: Qualitative algorithm for microwave colonoscopy
Description:
(English) This thesis develops and validates an innovative algorithm for colorectal cancer (CRC) detection using microwaves, integrating it into endoscopic procedures.
Validation includes ex-vivo, in-vivo, and clinical trials.
The algorithm enhances polyp detection by exploiting dielectric contrast between healthy and cancerous tissues, addressing colonoscopy limitations.
It normalizes signals, calibrates artifacts, reconstructs images, and applies automatic detection to improve sensitivity and specificity.
Key calibration strategies include First Frame Subtraction, Similar Frame Subtraction, Antenna-Pair Subtraction, and Previous Frames Averaging to isolate polyp scattering.
Automatic detection methods, such as Exponential Smoothing and Target-to-Clutter Ratio Thresholding, enable polyp identification regardless of anatomy.
The algorithm undergoes extensive preclinical testing with phantom models, ex-vivo tissues, and in-vivo pig trials, evaluating detection accuracy through sensitivity, specificity, and mismatch metrics.
A pilot clinical trial validates real-world performance.
Optimization involves refining a phantom model to simulate colonoscopy conditions and tuning algorithm parameters for a second clinical trial.
These advancements position microwave-based detection as a promising CRC screening alternative.
The research demonstrates the potential of microwave imaging to improve diagnostics, offering real-time, automated polyp detection with meaningful clinical impact.
(Català) Aquesta tesi desenvolupa i valida un algoritme innovador per a la detecció del càncer colorectal (CRC) mitjançant microones, integrant-lo en endoscòpies.
La validació inclou proves ex-vivo, in-vivo i assaigs clínics.
L’algoritme millora la detecció de pòlips aprofitant el contrast dielèctric entre teixits sans i cancerosos, superant les limitacions de la colonoscòpia.
Per fer-ho, normalitza senyals, calibra artefactes, reconstrueix imatges i aplica detecció automàtica per augmentar la sensibilitat i especificitat.
Les estratègies de calibratge inclouen First Frame Subtraction, Similar Frame Subtraction, Antenna-Pair Subtraction i Previous Frames Averaging per aïllar la dispersió dels pòlips.
Els mètodes Exponential Smoothing i Target-to-Clutter Ratio Thresholding permeten la detecció automàtica independentment de l’anatomia.
L’algoritme es prova en estudis preclínics amb models fantasma, teixits ex-vivo i assaigs in-vivo en porcs, avaluant sensibilitat, especificitat i desajust.
Un assaig clínic pilot valida la seva aplicació en endoscòpies reals.
L’optimització se centra en desenvolupar un model físic al laboratori que reprodueixi millor una colonoscòpia i ajustar els paràmetres per a un segon assaig clínic.
Aquests avenços posicionen la detecció amb microones com una alternativa prometedora per al cribratge del CRC, millorant el diagnòstic en temps real i l’eficiència sanitària.
(Español) Esta tesis desarrolla y valida un algoritmo innovador para la detección del cáncer colorrectal (CRC) mediante microondas, integrándolo en endoscopias.
Su validación incluye pruebas ex-vivo, in-vivo y ensayos clínicos.
El algoritmo mejora la detección de pólipos aprovechando la diferencia dieléctrica entre tejidos sanos y cancerosos, superando las limitaciones de la colonoscopia.
Para ello, normaliza señales, calibra artefactos, reconstruye imágenes y aplica detección automática para aumentar sensibilidad y especificidad.
Las estrategias de calibración incluyen First Frame Subtraction, Similar Frame Subtraction, Antenna-Pair Subtraction y Previous Frames Averaging para aislar la dispersión de pólipos.
Métodos avanzados como Exponential Smoothing y Target-to-Clutter Ratio Thresholding permiten la detección automática independientemente de la anatomía.
El algoritmo se evalúa en estudios preclínicos con modelos fantoma, tejidos ex-vivo y ensayos in-vivo en cerdos, midiendo sensibilidad, especificidad y desajuste.
Un ensayo clínico piloto valida su uso en endoscopias reales.
La optimización se centra en mejorar un modelo fantoma que simule con precisión una colonoscopia y en ajustar parámetros para un segundo ensayo clínico.
Estos avances posicionan la detección con microondas como una alternativa prometedora para el cribado del CRC, contribuyendo al diagnóstico en tiempo real y mejorando la eficiencia en salud.

Related Results

Low-Fibre Diet as an Option for Bowel Preparation Prior to Colonoscopy: ARandomised Controlled Clinical Trial
Low-Fibre Diet as an Option for Bowel Preparation Prior to Colonoscopy: ARandomised Controlled Clinical Trial
Introduction: Bowel preparation for colonoscopy plays an important role in the evaluation of the colon. Many methods for preparing the colon for colonoscopy do not work well. Aim:...
PillCam COLON 2 for investigation of the colon through direct visualisation: systematic review and economic evaluation
PillCam COLON 2 for investigation of the colon through direct visualisation: systematic review and economic evaluation
Background Colorectal cancer is the fourth most common cancer and the second most common cause of cancer deaths in England. Most cases of colorectal cancer aris...
1175 Ileal Carcinoid Tumors Detected During Screening versus Diagnostic Colonoscopy: Comparison of Tumor Characteristics
1175 Ileal Carcinoid Tumors Detected During Screening versus Diagnostic Colonoscopy: Comparison of Tumor Characteristics
INTRODUCTION: Small intestinal carcinoid tumors are the most common type of small bowel malignancy observed. Most are indolent and incidentally found in asymptomatic pa...
Chemical Kinetics of the Microwave Effect on the Base Hydrolysis Reaction Rate of Benzyl Isobutyrate
Chemical Kinetics of the Microwave Effect on the Base Hydrolysis Reaction Rate of Benzyl Isobutyrate
Many experimental results regarding Arrhenius plot on various chemical reactions under microwave irradiation have been reported. According to these results, it can be confirmed in ...
Screening Colonoscopy Uptake Among Adult Stroke Survivors: Findings from the 2022 BRFSS Data
Screening Colonoscopy Uptake Among Adult Stroke Survivors: Findings from the 2022 BRFSS Data
Background/Objectives: Colorectal cancer (CRC) is the second leading cause of cancer-related deaths globally. Screening for cancer helps to prevent comorbid conditions among indivi...
G-EYE Colonoscopy Is Superior to Standard Colonoscopy for Increasing Adenoma/Polyp Detection Rate
G-EYE Colonoscopy Is Superior to Standard Colonoscopy for Increasing Adenoma/Polyp Detection Rate
Abstract Background Colorectal cancer (CRC) is one of the most common cancers worldwide. Most CRCs develop from malignant potent...
ARTIFICIAL INTELLIGENCE APPLICATION IN COLONOSCOPY SCREENING: A LITERATURE REVIEW
ARTIFICIAL INTELLIGENCE APPLICATION IN COLONOSCOPY SCREENING: A LITERATURE REVIEW
Background: Colorectal cancer (CRC) is the third most commonly diagnosed cancer globally and remains a leading cause of cancer-related deaths. Despite the effectiveness of colonosc...

Back to Top