Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Standardized flattening filter free volumetric modulated arc therapy plans based on anteroposterior width for total body irradiation

View through CrossRef
AbstractIn this work, the feasibility of using flattening filter free (FFF) beams in volumetric modulated arc therapy (VMAT) total body irradiation (TBI) treatment planning to decrease protracted beam‐on times for these treatments was investigated. In addition, a methodology was developed to generate standardized VMAT TBI treatment plans based on patient physical dimensions to eliminate plan optimization time. A planning study cohort of 47 TBI patients previously treated with optimized VMAT ARC 6 MV beams was retrospectively examined. These patients were sorted into six categories depending on height and anteroposterior (AP) width at the umbilicus. Using Varian Eclipse, clinical 40 cm × 10 cm open field arcs were substituted with 6 MV FFF. Mid‐plane lateral dose profiles in conjunction with relative arc output factors (RAOF) yielded how far a given multileaf collimator (MLC) leaf must move in order to achieve a mid‐plane 100% isodose for a specific control point. Linear interpolation gave the dynamic MLC aperture for the entire arc for each patient AP width category, which was subsequently applied through Python scripting. All FFF VMAT TBI plans were then evaluated by two radiation oncologists and deemed clinically acceptable. The FFF and clinical VMAT TBI plans had similar Body–5 mm D98% distributions, but overall the FFF plans had statistically significantly increased or broader Body–5 mm D2% and mean lung dose distributions. These differences are not considered clinically significant. Median beam‐on times for the FFF and clinical VMAT TBI plans were 11.07 and 18.06 min, respectively, and planning time for the FFF VMAT TBI plans was reduced by 34.1 min. In conclusion, use of FFF beams in VMAT TBI treatment planning resulted in dose homogeneity similar to our current VMAT TBI technique. Clinical dosimetric criteria were achieved for a majority of patients while planning and calculated beam‐on times were reduced, offering the possibility of improved patient experience.
Title: Standardized flattening filter free volumetric modulated arc therapy plans based on anteroposterior width for total body irradiation
Description:
AbstractIn this work, the feasibility of using flattening filter free (FFF) beams in volumetric modulated arc therapy (VMAT) total body irradiation (TBI) treatment planning to decrease protracted beam‐on times for these treatments was investigated.
In addition, a methodology was developed to generate standardized VMAT TBI treatment plans based on patient physical dimensions to eliminate plan optimization time.
A planning study cohort of 47 TBI patients previously treated with optimized VMAT ARC 6 MV beams was retrospectively examined.
These patients were sorted into six categories depending on height and anteroposterior (AP) width at the umbilicus.
Using Varian Eclipse, clinical 40 cm × 10 cm open field arcs were substituted with 6 MV FFF.
Mid‐plane lateral dose profiles in conjunction with relative arc output factors (RAOF) yielded how far a given multileaf collimator (MLC) leaf must move in order to achieve a mid‐plane 100% isodose for a specific control point.
Linear interpolation gave the dynamic MLC aperture for the entire arc for each patient AP width category, which was subsequently applied through Python scripting.
All FFF VMAT TBI plans were then evaluated by two radiation oncologists and deemed clinically acceptable.
The FFF and clinical VMAT TBI plans had similar Body–5 mm D98% distributions, but overall the FFF plans had statistically significantly increased or broader Body–5 mm D2% and mean lung dose distributions.
These differences are not considered clinically significant.
Median beam‐on times for the FFF and clinical VMAT TBI plans were 11.
07 and 18.
06 min, respectively, and planning time for the FFF VMAT TBI plans was reduced by 34.
1 min.
In conclusion, use of FFF beams in VMAT TBI treatment planning resulted in dose homogeneity similar to our current VMAT TBI technique.
Clinical dosimetric criteria were achieved for a majority of patients while planning and calculated beam‐on times were reduced, offering the possibility of improved patient experience.

Related Results

Tijelo u opusu Janka Polića Kamova
Tijelo u opusu Janka Polića Kamova
The doctoral disertation is dedicated to the concept of the body in the works of Janko Polić Kamov. The body is approached as a signifier system on the basis of which numerous and ...
Geomorphology and Geochemistry of Back Arc Basins in the Havre Trough, Southwest Pacific
Geomorphology and Geochemistry of Back Arc Basins in the Havre Trough, Southwest Pacific
<p>The Havre Trough back arc system located behind the Kermadec Arc, in the southwest Pacific, is a classic example of an intra-oceanic back arc system. Subduction driven mag...
Back‐arc rifting in the Izu‐Bonin Island Arc: Structural evolution of Hachijo and Aoga Shima Rifts
Back‐arc rifting in the Izu‐Bonin Island Arc: Structural evolution of Hachijo and Aoga Shima Rifts
Abstract Multi‐ and single‐channel seismic profiles are used to investigate the structural evolution of back‐arc rifting in the intra‐oceanic Izu‐Bonin Arc. Hachijo and Aoga ...
Dosimetric comparison of TomoDirect, helical tomotherapy, and volumetric modulated arc therapy for postmastectomy treatment
Dosimetric comparison of TomoDirect, helical tomotherapy, and volumetric modulated arc therapy for postmastectomy treatment
AbstractPurposeTo compare dose to the targets and organs at risk (OARs) in different situations for postmastectomy patients who require radiation to the chest wall with or without ...
CFD Simulation and Optimization of a Cake Filtration System
CFD Simulation and Optimization of a Cake Filtration System
Abstract This study presents a simulation of filter cake formation during the filtration of rice hull ash and liquid mixture using ANSYS Fluent software. Filter cake...
SU‐E‐T‐458: Impact of Parameters for Volumetric Modulated Arc Therapy (VMAT) for Rectal Cancer
SU‐E‐T‐458: Impact of Parameters for Volumetric Modulated Arc Therapy (VMAT) for Rectal Cancer
Purpose:Different parameters Result in different plans. As the developing of volumetric modulated arc therapy for rectal cancer, the purpose of this study was to work out appropria...
Evidence of Language Contact: Source Prepositional Phrases in Taiwanese Southern Min
Evidence of Language Contact: Source Prepositional Phrases in Taiwanese Southern Min
<p align="center"><strong>Evidence of Language Contact: Data from source Prepositional Phrases in Taiwanese Southern Min </strong></p><p><strong>...
Morphometric analysis of distal femur through MRI in Turkish population and review of the literature
Morphometric analysis of distal femur through MRI in Turkish population and review of the literature
Measurements of the distal femur are highly variable among different subjects. To obtain the best stability and longevity of the knee implants, anthropometric data of the distal fe...

Back to Top