Development of Auto Thermal Control Device For Space Air - Conditioning

View through CrossRef
Auto Thermal Control device is an electronic based device which employs the application of temperature sensors to controlling household appliances without human interference directly. In this work, thermal source is used to regulate electrical fan and room heater depending on ambient temperature. The room heater, which is adjusted to a set temperature, switches ‘ON’ when the temperature of a room is low (cold). While the same is switches ‘OFF’ with increase in the room temperature. This triggers ‘ON’ an electric fan at different speeds, and thus cools the room. A temperature sensor, tthermistor, monitors change in room temperature. Two types of thermistor exists: Positive Temperature Coefficient, PTC. An increasee in the resistance of PTC results in increasee in temperature). In the Negative Temperature Coefficient, NTC; a decreasee in resistance yields to temperature increase. This article explored a NTC thermistor. The design could be a ready product in the market of the developing nation where environmental automation is yet fully deployed.
Title: Development of Auto Thermal Control Device For Space Air - Conditioning
Description:
Auto Thermal Control device is an electronic based device which employs the application of temperature sensors to controlling household appliances without human interference directly.
In this work, thermal source is used to regulate electrical fan and room heater depending on ambient temperature.
The room heater, which is adjusted to a set temperature, switches ‘ON’ when the temperature of a room is low (cold).
While the same is switches ‘OFF’ with increase in the room temperature.
This triggers ‘ON’ an electric fan at different speeds, and thus cools the room.
A temperature sensor, tthermistor, monitors change in room temperature.
Two types of thermistor exists: Positive Temperature Coefficient, PTC.
An increasee in the resistance of PTC results in increasee in temperature).
In the Negative Temperature Coefficient, NTC; a decreasee in resistance yields to temperature increase.
This article explored a NTC thermistor.
The design could be a ready product in the market of the developing nation where environmental automation is yet fully deployed.

Related Results

Thermal Effects in High Compactness CEA Stack
Thermal Effects in High Compactness CEA Stack
Thermal management is a pivotal aspect of stack durability and system operability. Consequently, understanding the thermal mapping within a stack based on its operating conditions ...
Theoretical and Experimental Investigations of Solar-Thermoelectric Air-Conditioning System for Remote Applications
Theoretical and Experimental Investigations of Solar-Thermoelectric Air-Conditioning System for Remote Applications
In this paper, we have designed and constructed a low cost solar-thermoelectric (TE) air-conditioning system for people in remote areas where electricity is still in short supply. ...
Air convection in coarse blocky permafrost : a numerical modelling approach to improve the understanding of the ground thermal regime
Air convection in coarse blocky permafrost : a numerical modelling approach to improve the understanding of the ground thermal regime
Permafrost is a thermal phenomenon, defined as subsurface material with a temperature remaining below 0°C for at least two consecutive years. Permafrost occurs at high latitudes an...
Comparison of Conditioning Regimens (BeEAC, CLV, LEAM) before Auto-HSCT in Patients with Relapsed and Refractory Hodgkin Lymphoma
Comparison of Conditioning Regimens (BeEAC, CLV, LEAM) before Auto-HSCT in Patients with Relapsed and Refractory Hodgkin Lymphoma
Введение. Высокодозная химиотерапия с последующей аутологичной трансплантацией гемопоэтических стволовых клеток (ВДХТ и ауто-ТГСК) остается стандартом лечения пациентов с первично-...
Nonlinear optimal control for robotic exoskeletons with electropneumatic actuators
Nonlinear optimal control for robotic exoskeletons with electropneumatic actuators
Purpose To provide high torques needed to move a robot’s links, electric actuators are followed by a transmission system with a high transmission rate. For instance, gear ratios of...
Removal of toxic vapors by oxidation: Development of laboratory test procedures for in-duct air cleaning systems
Removal of toxic vapors by oxidation: Development of laboratory test procedures for in-duct air cleaning systems
Exposure to volatile organic compounds (VOC) in workplaces can cause acute effects such as irritation of the skin, the eyes, the mouth, and the nose. Some products may also cause c...
Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
EnvironmentalSurveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) This comprehensive protocol suite enables systematic environmental surveillance for avian influenza...
Analysis on The Risk of Respiratory Virus Transmission By Air Conditioning System Operation-Based on Experimental Evidence
Analysis on The Risk of Respiratory Virus Transmission By Air Conditioning System Operation-Based on Experimental Evidence
Abstract It is important to know whether SARS-CoV-2 is spread through the air-conditioning systems. Taking the central air-conditioning system as an example, we analyze the...