Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Long-Term Assessment of Inter-Sensor Radiometric Biases Among SNPP, NOAA-20, NOAA-21 OMPS Nadir and CrIS Instruments Using the NOAA ICVS Framework

View through CrossRef
This study presents a long-term assessment of inter-sensor radiometric calibration biases for NOAA OMPS nadir and CrIS instruments using four well-established validation methodologies implemented through the Inter-Sensor Radiometric Bias Assessment (iSensor-RCBA) portal, a component of the STAR Integrated Calibration/Validation System (ICVS) monitoring system. Four validation methods include the 32-Day Average, CRTM-DD, SNO, and Sensor-DD via SNO—to enhance monitoring and detect radiometric errors. The results demonstrate that the SDR data quality from three OMPS nadir instruments and three CrIS instruments aboard the SNPP, NOAA-20, and NOAA-21 satellites has generally remained stable over the long term, meeting scientific requirements with some margin—mainly during early orbit phases, anomalies, malfunctions, or calibration updates. Among four methodologies, the 32-Day method excels in identifying limitations of other used validation methods, particularly in terms of inter-sensor bias geographical coverage. For instance, the 32-Day method identifies an unusual feature in the NOAA-21 CrIS SDR data over the high latitudes of the Southern Hemisphere during the spring and summer seasons, which was not detected using the other three methods due to a limited coverage. The SNO method is particularly effective for detecting long-term calibration discrepancies in a single instrument. This is illustrated by an approximately 10-year time series of inter-sensor bias between SNPP OMPS Nadir Mapper and Metop-B GOME-2, which reveals significant degradation in GOME-2. Using the SNO method, two significant geolocation problems occurred on SNPP spacecraft were captured in inter-sensor biases between SNPP CrIS and GOES-16 ABI. Therefore, the iSensor-RCBA portal can serve as a crucial tool for providing supplemental information about long-term radiometric calibration stability of satellite radiance data across JPSS and other satellite instruments.
Title: Long-Term Assessment of Inter-Sensor Radiometric Biases Among SNPP, NOAA-20, NOAA-21 OMPS Nadir and CrIS Instruments Using the NOAA ICVS Framework
Description:
This study presents a long-term assessment of inter-sensor radiometric calibration biases for NOAA OMPS nadir and CrIS instruments using four well-established validation methodologies implemented through the Inter-Sensor Radiometric Bias Assessment (iSensor-RCBA) portal, a component of the STAR Integrated Calibration/Validation System (ICVS) monitoring system.
Four validation methods include the 32-Day Average, CRTM-DD, SNO, and Sensor-DD via SNO—to enhance monitoring and detect radiometric errors.
The results demonstrate that the SDR data quality from three OMPS nadir instruments and three CrIS instruments aboard the SNPP, NOAA-20, and NOAA-21 satellites has generally remained stable over the long term, meeting scientific requirements with some margin—mainly during early orbit phases, anomalies, malfunctions, or calibration updates.
Among four methodologies, the 32-Day method excels in identifying limitations of other used validation methods, particularly in terms of inter-sensor bias geographical coverage.
For instance, the 32-Day method identifies an unusual feature in the NOAA-21 CrIS SDR data over the high latitudes of the Southern Hemisphere during the spring and summer seasons, which was not detected using the other three methods due to a limited coverage.
The SNO method is particularly effective for detecting long-term calibration discrepancies in a single instrument.
This is illustrated by an approximately 10-year time series of inter-sensor bias between SNPP OMPS Nadir Mapper and Metop-B GOME-2, which reveals significant degradation in GOME-2.
Using the SNO method, two significant geolocation problems occurred on SNPP spacecraft were captured in inter-sensor biases between SNPP CrIS and GOES-16 ABI.
Therefore, the iSensor-RCBA portal can serve as a crucial tool for providing supplemental information about long-term radiometric calibration stability of satellite radiance data across JPSS and other satellite instruments.

Related Results

Continuing the MLS water vapor record with OMPS LP
Continuing the MLS water vapor record with OMPS LP
Abstract. Stratospheric water vapor (SWV) plays an important role in atmospheric chemistry, dynamics, and radiative forcing. Satellite measurements by the Aura Microwave Limb Sound...
Ten Years of SNPP VIIRS Reflective Solar Bands On-Orbit Calibration and Performance
Ten Years of SNPP VIIRS Reflective Solar Bands On-Orbit Calibration and Performance
The Visible Infrared Imaging Radiometer Suite (VIIRS) onboard the Suomi National Polar-orbiting Partnership (SNPP) has successfully operated on-orbit for nearly ten years since its...
Ten Years of VIIRS On-Orbit Geolocation Calibration and Performance
Ten Years of VIIRS On-Orbit Geolocation Calibration and Performance
The first innovative Visible Infrared Imaging Radiometer Suite (VIIRS) sensor aboard the Suomi National Polar-orbiting Partnership (SNPP) satellite has been in operation for 10 yea...
Dynamic stochastic modeling for inertial sensors
Dynamic stochastic modeling for inertial sensors
Es ampliamente conocido que los modelos de error para sensores inerciales tienen dos componentes: El primero es un componente determinista que normalmente es calibrado por el fabri...
Correction to: J Endourol Videourology. 2017, DOI: 10.1089/vid.2016.0066
Correction to: J Endourol Videourology. 2017, DOI: 10.1089/vid.2016.0066
The video article entitled “Extraperitoneal Video-Assisted Simple Prostatectomy: A Surgery for Beginners?” by Mota et al . (DOI: VID-2016-00...
Surface proteomics of Leptospira interrogans serovar Pomona
Surface proteomics of Leptospira interrogans serovar Pomona
Leptospirosis is a re-emerging zoonosis of global distribution including Thailand. It caused by pathogenic Leptospira. The pathogenesis is not clear. Surface-exposed proteins (PSEs...

Back to Top