Javascript must be enabled to continue!
Long-Term Assessment of Inter-Sensor Radiometric Biases Among SNPP, NOAA-20, NOAA-21 ATMS, and NOAA-19 AMSU-A Instruments Using the NOAA ICVS Framework
View through CrossRef
This study evaluates mission-long inter-sensor radiometric calibration biases in Sensor Data Record (SDR) and/or Temperature Data Record (TDR) radiances from NOAA microwave sounders, including Advanced Technology Microwave Sounder (ATMS) (Suomi National Polar-orbiting Partnership or SNPP, NOAA-20, NOAA-21) and Advanced Microwave Sounding Unit-A (AMSU-A) (NOAA-19). Using four complementary validation techniques within the Inter-Sensor Radiometric Bias Assessment (iSensor-RCBA) system—32-day averaging, Community Radiative Transfer Model (CRTM) Double Difference (DD), Simultaneously Nadir Overpass (SNO), and sensor-DD via SNO—we characterize long-term performance. Results indicate that the SDR/TDR radiance quality remains stable and generally meets scientific requirements throughout their operational lifetimes with minimal anomalies; observed anomalies were infrequent and primarily correlated with calibration-table updates or spacecraft events or instrument degradation. Moreover, this research examines how radiometric calibration biases for the three ATMS instruments vary with Earth scene radiance or temperatures using the CRTM and SNO methods, as well as the radiance-dependency of inter-sensor calibration biases across the three instruments. Notably, due to its exceptional stability over 14 years, despite an approximate two-month data gap, the SNPP ATMS TDR and SDR datasets are recommended as the ideal reference to link legacy AMSU-A and Microwave Humidity Sounder (MHS) with Joint Polar Satellite System (JPSS), QuickSounder, and MetOp-Second Generation (MetOp-SG) microwave instruments. Beyond quantifying data quality, our multi-method framework with iSensor-RCBA effectively diagnosed critical issues, including a simulation error for CRTM ATMS radiance related to the CRTM spectral-response approximation and a NOAA-19 AMSU-A channel-8 performance anomaly. These findings confirm the long-term integrity of NOAA microwave sounder records and reinforce the value of integrated cross-sensor calibration assessments.
Title: Long-Term Assessment of Inter-Sensor Radiometric Biases Among SNPP, NOAA-20, NOAA-21 ATMS, and NOAA-19 AMSU-A Instruments Using the NOAA ICVS Framework
Description:
This study evaluates mission-long inter-sensor radiometric calibration biases in Sensor Data Record (SDR) and/or Temperature Data Record (TDR) radiances from NOAA microwave sounders, including Advanced Technology Microwave Sounder (ATMS) (Suomi National Polar-orbiting Partnership or SNPP, NOAA-20, NOAA-21) and Advanced Microwave Sounding Unit-A (AMSU-A) (NOAA-19).
Using four complementary validation techniques within the Inter-Sensor Radiometric Bias Assessment (iSensor-RCBA) system—32-day averaging, Community Radiative Transfer Model (CRTM) Double Difference (DD), Simultaneously Nadir Overpass (SNO), and sensor-DD via SNO—we characterize long-term performance.
Results indicate that the SDR/TDR radiance quality remains stable and generally meets scientific requirements throughout their operational lifetimes with minimal anomalies; observed anomalies were infrequent and primarily correlated with calibration-table updates or spacecraft events or instrument degradation.
Moreover, this research examines how radiometric calibration biases for the three ATMS instruments vary with Earth scene radiance or temperatures using the CRTM and SNO methods, as well as the radiance-dependency of inter-sensor calibration biases across the three instruments.
Notably, due to its exceptional stability over 14 years, despite an approximate two-month data gap, the SNPP ATMS TDR and SDR datasets are recommended as the ideal reference to link legacy AMSU-A and Microwave Humidity Sounder (MHS) with Joint Polar Satellite System (JPSS), QuickSounder, and MetOp-Second Generation (MetOp-SG) microwave instruments.
Beyond quantifying data quality, our multi-method framework with iSensor-RCBA effectively diagnosed critical issues, including a simulation error for CRTM ATMS radiance related to the CRTM spectral-response approximation and a NOAA-19 AMSU-A channel-8 performance anomaly.
These findings confirm the long-term integrity of NOAA microwave sounder records and reinforce the value of integrated cross-sensor calibration assessments.
Related Results
Long-Term Assessment of Inter-Sensor Radiometric Biases Among SNPP, NOAA-20, NOAA-21 OMPS Nadir and CrIS Instruments Using the NOAA ICVS Framework
Long-Term Assessment of Inter-Sensor Radiometric Biases Among SNPP, NOAA-20, NOAA-21 OMPS Nadir and CrIS Instruments Using the NOAA ICVS Framework
This study presents a long-term assessment of inter-sensor radiometric calibration biases for NOAA OMPS nadir and CrIS instruments using four well-established validation methodolog...
Technology of AIRS/AMSU/ATMS satellite data processing
Technology of AIRS/AMSU/ATMS satellite data processing
The Atmospheric Infrared Sounder (AIRS) is a hyperspectral instrument with 2378 channels. It is a part of the Aqua space platform equipment. It registers outgoing longwave radiatio...
Ten Years of SNPP VIIRS Reflective Solar Bands On-Orbit Calibration and Performance
Ten Years of SNPP VIIRS Reflective Solar Bands On-Orbit Calibration and Performance
The Visible Infrared Imaging Radiometer Suite (VIIRS) onboard the Suomi National Polar-orbiting Partnership (SNPP) has successfully operated on-orbit for nearly ten years since its...
Ten Years of VIIRS On-Orbit Geolocation Calibration and Performance
Ten Years of VIIRS On-Orbit Geolocation Calibration and Performance
The first innovative Visible Infrared Imaging Radiometer Suite (VIIRS) sensor aboard the Suomi National Polar-orbiting Partnership (SNPP) satellite has been in operation for 10 yea...
Dynamic stochastic modeling for inertial sensors
Dynamic stochastic modeling for inertial sensors
Es ampliamente conocido que los modelos de error para sensores inerciales tienen dos componentes: El primero es un componente determinista que normalmente es calibrado por el fabri...
IoT Enable Smart Heath ATM and Selecting the Optimal Location using Minimal Vertex Cover
IoT Enable Smart Heath ATM and Selecting the Optimal Location using Minimal Vertex Cover
Abstract
Objective
: Health ATMs are touch-operated machines that use sensors to measure test readings and provides test result...
Correction to:
J Endourol Videourology. 2017, DOI: 10.1089/vid.2016.0066
Correction to:
J Endourol Videourology. 2017, DOI: 10.1089/vid.2016.0066
The video article entitled “Extraperitoneal Video-Assisted Simple Prostatectomy: A Surgery for Beginners?” by Mota
et al
. (DOI: VID-2016-00...
Adipose tissue macrophages induce PPARγ-high FOXP3+ regulatory T cells
Adipose tissue macrophages induce PPARγ-high FOXP3+ regulatory T cells
AbstractNumerous regulatory T cells (Tregs) are present in adipose tissues compared with other lymphoid or non-lymphoid tissues. Adipose Tregs regulate inflammatory state and insul...

