Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Investigation of the Transfer Capability of the Nigerian 330 kV, 58-bus Power System Network using FACTS Devices

View through CrossRef
Over the years, the Nigerian power system is beset with lingering problems, which include severe power losses, as well as very low transfer capability of the transmission network to evacuate power from generating stations to the load at the distribution level. Presently, the Nigerian power industry is undergoing restructuring, especially in the generation and distribution systems. In view of the deregulation of electricity distribution and marketing, the traditional practices of the Nigerian power system are undergoing changes to address the identified problems in the existing power system. Specifically, better utilization of the existing power transmission network to improve on the system transfer capability and minimize cost is one of the key focuses of the deregulation agenda. This work deals with the enhancement of transfer capability of Nigerian 58-bus, 330kV network using FACTS (Flexible Alternating Current Transmission System) devices. FACTS devices are used for controlling transmission voltage, power flow, reducing reactive power losses, and damping of power system oscillations for high power transfer capability. Three FACTS devices; Thyristor Controlled Series Compensator (TCSC), Unified Power Flow Controller (UPFC), and Interline Power Flow Controller (IPFC) were used to investigate the transfer capability of the Nigerian 58-bus power system network. NEPLAN was employed in this work to model the Nigerian 58-bus system and optimally placed the FACTS devices at the weakest buses that were found out through the computation for available transfer capability (ATC) after continuation power flow (CPF) simulation was completed. MATLAB codes were developed and used to calculate power transfer capability of the network without and with FACTS devices. Comparing the three FACTS devices, the results obtained showed that UPFC enhanced the power transfer capability of the network than TCSC and IPFC.
Title: Investigation of the Transfer Capability of the Nigerian 330 kV, 58-bus Power System Network using FACTS Devices
Description:
Over the years, the Nigerian power system is beset with lingering problems, which include severe power losses, as well as very low transfer capability of the transmission network to evacuate power from generating stations to the load at the distribution level.
Presently, the Nigerian power industry is undergoing restructuring, especially in the generation and distribution systems.
In view of the deregulation of electricity distribution and marketing, the traditional practices of the Nigerian power system are undergoing changes to address the identified problems in the existing power system.
Specifically, better utilization of the existing power transmission network to improve on the system transfer capability and minimize cost is one of the key focuses of the deregulation agenda.
This work deals with the enhancement of transfer capability of Nigerian 58-bus, 330kV network using FACTS (Flexible Alternating Current Transmission System) devices.
FACTS devices are used for controlling transmission voltage, power flow, reducing reactive power losses, and damping of power system oscillations for high power transfer capability.
Three FACTS devices; Thyristor Controlled Series Compensator (TCSC), Unified Power Flow Controller (UPFC), and Interline Power Flow Controller (IPFC) were used to investigate the transfer capability of the Nigerian 58-bus power system network.
NEPLAN was employed in this work to model the Nigerian 58-bus system and optimally placed the FACTS devices at the weakest buses that were found out through the computation for available transfer capability (ATC) after continuation power flow (CPF) simulation was completed.
MATLAB codes were developed and used to calculate power transfer capability of the network without and with FACTS devices.
Comparing the three FACTS devices, the results obtained showed that UPFC enhanced the power transfer capability of the network than TCSC and IPFC.

Related Results

Analisis Kapasitor Bank Untuk Memperbaiki Tegangan
Analisis Kapasitor Bank Untuk Memperbaiki Tegangan
Tenaga Listrik disalurkan kekonsumen melalui sistem tenaga listrik yang terdiri dari beberapa sub sistem yaitu  pembangkit, transmisi, dan distribusi. Penyulang Gurami Gardu Induk ...
Pelayanan Bus Patas dan Ekonomi Pada Trayek Antar Kota
Pelayanan Bus Patas dan Ekonomi Pada Trayek Antar Kota
Penelitian ini bertujuan untuk melakukan kajian kinerja pelayanan bus antar kota cepat terbatas (patas) dan ekonomi. Dalam pengambilan data, digunakan skala likert (numerik) untuk ...
Optimizing Dallas-Fort Worth Bus Transportation System Using Any Logic
Optimizing Dallas-Fort Worth Bus Transportation System Using Any Logic
The bus transportation system, modeled using the AnyLogic simulation software, aims to optimize the flow of buses and manage key operational challenges such as bus bunching and del...
ROLE OF FACTS DEVICES IN POWER SYSTEM WITH OPTIMIZATION TECHNIQUES
ROLE OF FACTS DEVICES IN POWER SYSTEM WITH OPTIMIZATION TECHNIQUES
In electrical power systems, FACTS devices effectively control power flow and change bus voltages, leading to lower system losses and excellent system stability. The article discus...
Komparasi Biaya Operasional Kendaraan (BOK) Bus Diesel dengan Bus Listrik (Studi Kasus : Koridor Lapangan Merdeka-Tembung)
Komparasi Biaya Operasional Kendaraan (BOK) Bus Diesel dengan Bus Listrik (Studi Kasus : Koridor Lapangan Merdeka-Tembung)
Perbandingan biaya operasional antara bus diesel dan bus listrik dalam sistem transportasi umum perkotaan menjadi penting untuk evaluasi keberlanjutan ekonomi dan lingkungan. Korid...
Evaluasi Terminal Tipe A - Willy Ananias Gara (W.A. Gara) Kota Palangkaraya
Evaluasi Terminal Tipe A - Willy Ananias Gara (W.A. Gara) Kota Palangkaraya
The study aims to find factors that generated the ineffective utilization of W.A Gara bus station as the only type A bus station in Palangka Raya and find the strategies for more e...
Evaluation and Analysis of Available Transfer Capability in Deregulated Power System Environment
Evaluation and Analysis of Available Transfer Capability in Deregulated Power System Environment
Reliability of network is need of the hour in the present power system market and is constrained by capability of the network. The network calculations are performed using accurate...
A Real-Time Control Strategy for Bus Operation to Alleviate Bus Bunching
A Real-Time Control Strategy for Bus Operation to Alleviate Bus Bunching
In order to alleviate bus bunching and improve the balance and punctuality rate of bus operation, a single-line real-time control strategy based on Intelligent Transportation Syste...

Back to Top