Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

The Number of Perforators Included in Reversed Flow Posterior Interosseous Artery Flap: Does It Affect the Incidence of Venous Congestion?

View through CrossRef
Background: The purpose of this study is to decrease the incidence of venous congestion occurring in the reversed flow posterior interosseous artery flap used for coverage of hand defects. Methods: This may be achieved by studying the incidence of venous congestion in flaps including only 1 perforator and comparing the results with others including more than 1 perforator both in small and large sized flaps. Results: This study showed that inclusion of only 1 perforator in the flap decreased the incidence of venous congestion with complete flap loss in flaps to 5%. Also, it decreased the incidence of venous congestion with partial flap loss in flaps to 10%. Conclusions: The small sized reversed flow posterior interosseous artery flap should be less than 40 cm2 and should include only 1 perforator to decrease the incidence of venous congestion with partial and complete loss of the flap. The level of evidence for this study is the type II prospective comparative study.
Title: The Number of Perforators Included in Reversed Flow Posterior Interosseous Artery Flap: Does It Affect the Incidence of Venous Congestion?
Description:
Background: The purpose of this study is to decrease the incidence of venous congestion occurring in the reversed flow posterior interosseous artery flap used for coverage of hand defects.
Methods: This may be achieved by studying the incidence of venous congestion in flaps including only 1 perforator and comparing the results with others including more than 1 perforator both in small and large sized flaps.
Results: This study showed that inclusion of only 1 perforator in the flap decreased the incidence of venous congestion with complete flap loss in flaps to 5%.
Also, it decreased the incidence of venous congestion with partial flap loss in flaps to 10%.
Conclusions: The small sized reversed flow posterior interosseous artery flap should be less than 40 cm2 and should include only 1 perforator to decrease the incidence of venous congestion with partial and complete loss of the flap.
The level of evidence for this study is the type II prospective comparative study.

Related Results

Early Onset of Coronary Subclavian Steal Syndrome: A Case Report and Literature Review
Early Onset of Coronary Subclavian Steal Syndrome: A Case Report and Literature Review
Abstract Introduction Coronary subclavian steal syndrome (CSSS) is a rare phenomenon that often goes undiagnosed and causes severe complications, including death. This report prese...
Flap Blood Glucose as a Sensitive and Specific Indicator for Flap Venous Congestion: A Rodent Model Study
Flap Blood Glucose as a Sensitive and Specific Indicator for Flap Venous Congestion: A Rodent Model Study
Background: Flap blood glucose decreases when flap congestion occurs. The hypothesis that flap blood glucose works as an indicator for venous congestion was tested expe...
The suprafascial course of lower leg perforators: An anatomical study
The suprafascial course of lower leg perforators: An anatomical study
Background Perforator mapping has been well described in the literature. Once the suprafascial plane is reached, the course of perforators is considered constant. However, the sur...
On a Hunt for the “True” Septocutaneous Perforator: A Histology Cross-Section Study
On a Hunt for the “True” Septocutaneous Perforator: A Histology Cross-Section Study
Abstract Background Modern trends in reconstructive surgery involve the use of free perforator flaps to reduce the donor site morbidity. The course of perforator ves...
POSTERIOR INTEROSSEOUS NERVE ENTRAPMENT RELEASE SURGERY: A CASE REPORT AND REVIEW OF THE LITERATURE
POSTERIOR INTEROSSEOUS NERVE ENTRAPMENT RELEASE SURGERY: A CASE REPORT AND REVIEW OF THE LITERATURE
Objective Describe the clinical and paraclinical characteristics of the PIN syndrome and the result of the PIN entrapment release surgery. S...
The Effect of Muscle Exercise on Perforators Flow: A Prospective Cohort Study
The Effect of Muscle Exercise on Perforators Flow: A Prospective Cohort Study
Background and objectives: The metabolic response after exercise causes a significant increase in the muscle blood flow. While these effects are demonstrated for intra-muscular ves...
Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Abstract Introduction Immunoglobulin G4-related disease (IgG4-RD) is a recently identified immune-mediated condition that is debilitating and often overlooked. While IgG4-RD has be...

Back to Top