Flap Blood Glucose as a Sensitive and Specific Indicator for Flap Venous Congestion: A Rodent Model Study
View through CrossRef
Background:
Flap blood glucose decreases when flap congestion occurs. The hypothesis that flap blood glucose works as an indicator for venous congestion was tested experimentally, and flap congestion was reproduced in rodent models.
Methods:
Blood glucose levels of a rat abdominal skin flap, with or without its vein pedicle clamped, were checked before and every 10 minutes after flap elevation. In rats whose pedicle vein was shut off, it was further followed up every 5 minutes after declamping. To examine the effect of systemic blood glucose on flap blood glucose, in some rats, glucose solution was administered intraperitoneally before the experiment to artificially produce hyperglycemia. Forty-two rats were divided into four groups, with (n = 24) or without (n = 18) venous blockage and with (n = 20) or without (n = 22) glucose preloading.
Results:
Flap blood glucose decreased rapidly to off-scale low (<20 mg/dl) within 40 minutes only when the vein pedicle was shut off in normoglycemic (40 ± 8.2 minutes, mean ± SD) and hyperglycemic (40 ± 9.9 minutes) rat groups (p < 0.01). There was no significant difference in the time taken for the flap blood glucose to decrease to off-scale low after venous blockage between both groups (p = 0.379). When the vein was declamped, flap blood glucose again rapidly returned to the systemic level in 15 minutes or earlier in both groups (p = 0.0283).
Conclusions:
Flap blood glucose sensitively and specifically reflects the state of vein occlusion, whether the systemic blood glucose is normal or high. The authors’ results indicate that flap blood glucose works as a reliable indicator for the venous system.
Ovid Technologies (Wolters Kluwer Health)
Title: Flap Blood Glucose as a Sensitive and Specific Indicator for Flap Venous Congestion: A Rodent Model Study
Description:
Background:
Flap blood glucose decreases when flap congestion occurs.
The hypothesis that flap blood glucose works as an indicator for venous congestion was tested experimentally, and flap congestion was reproduced in rodent models.
Methods:
Blood glucose levels of a rat abdominal skin flap, with or without its vein pedicle clamped, were checked before and every 10 minutes after flap elevation.
In rats whose pedicle vein was shut off, it was further followed up every 5 minutes after declamping.
To examine the effect of systemic blood glucose on flap blood glucose, in some rats, glucose solution was administered intraperitoneally before the experiment to artificially produce hyperglycemia.
Forty-two rats were divided into four groups, with (n = 24) or without (n = 18) venous blockage and with (n = 20) or without (n = 22) glucose preloading.
Results:
Flap blood glucose decreased rapidly to off-scale low (<20 mg/dl) within 40 minutes only when the vein pedicle was shut off in normoglycemic (40 ± 8.
2 minutes, mean ± SD) and hyperglycemic (40 ± 9.
9 minutes) rat groups (p < 0.
01).
There was no significant difference in the time taken for the flap blood glucose to decrease to off-scale low after venous blockage between both groups (p = 0.
379).
When the vein was declamped, flap blood glucose again rapidly returned to the systemic level in 15 minutes or earlier in both groups (p = 0.
0283).
Conclusions:
Flap blood glucose sensitively and specifically reflects the state of vein occlusion, whether the systemic blood glucose is normal or high.
The authors’ results indicate that flap blood glucose works as a reliable indicator for the venous system.
Related Results
Pregnancy and Challenging Transient Anti-GAD65 Positivity: A Case Report with Literature Review
Pregnancy and Challenging Transient Anti-GAD65 Positivity: A Case Report with Literature Review
Abstract
Introduction
During pregnancy, women may develop blood glucose abnormalities like gestational diabetes mellitus (GDM) or, rarely, type 1 diabetes (T1D), which can lead to ...
[RETRACTED] Guardian Blood Balance –Feel the difference Guardian Blood Balance makes! v1
[RETRACTED] Guardian Blood Balance –Feel the difference Guardian Blood Balance makes! v1
[RETRACTED]Guardian Blood Balance Reviews (Works Or Hoax) Does Guardian Botanicals Blood Balance AU Really Works? Read Updated Report! Diabetes and Hypertension is such a health p...
Glucose intolerance is associated with resting heart rate among individuals without diabetes
Glucose intolerance is associated with resting heart rate among individuals without diabetes
Elevated resting heart rate is associated with cardiovascular diseases and all-cause mortality. Unmanaged diabetes is associated with high blood pressure and high resting heart rat...
[RETRACTED] Guardian Blood Balance Australia- Reviews - Guardian Botanicals Blood Balance [AU] SCAM ALERT! Read Real Critical Reports.. Price in Australia v1
[RETRACTED] Guardian Blood Balance Australia- Reviews - Guardian Botanicals Blood Balance [AU] SCAM ALERT! Read Real Critical Reports.. Price in Australia v1
[RETRACTED]Guardian Blood Balance Australia Reviews - Diabetes and blood sugar are some of the common problems that are attacking so many adult individuals nowadays. Obesity is t...
Effects of herbal tea (Platostoma palustre) on blood glucose regulation in vivo
Effects of herbal tea (Platostoma palustre) on blood glucose regulation in vivo
Platostoma palustre jelly is a traditional food. Platostoma palustre has been used as folk medicine and is effective against heat-shock, hypertension and diabetes. Therefore, the a...
Rodent Species Distribution and Hantavirus Seroprevalence in Residential and Forested areas of Sarawak, Malaysia
Rodent Species Distribution and Hantavirus Seroprevalence in Residential and Forested areas of Sarawak, Malaysia
Rodents belong to the order Rodentia, which consists of three families in Borneo (i.e., Muridae, Sciuridae and Hystricidae). These include rats, mice, squirrels, and porcupines. Th...
Comparison of capillary, venous and buffy coat blood samples in detecting Plasmodium species among malaria suspected patients attending at Hamusite health center. A cross-sectional study
Comparison of capillary, venous and buffy coat blood samples in detecting Plasmodium species among malaria suspected patients attending at Hamusite health center. A cross-sectional study
Abstract
Background
Both capillary and venous blood samples have been interchangeably used for the diagnosis of malaria in Ethiopia. However, Plasmo...
Twenty‐four‐hour variations in blood glucose level in Japanese type 2 diabetes patients based on continuous glucose monitoring
Twenty‐four‐hour variations in blood glucose level in Japanese type 2 diabetes patients based on continuous glucose monitoring
AbstractAims/IntroductionHigh fluctuations in blood glucose are associated with various complications. The correlation between glycated hemoglobin (HbA1c) level and fluctuations in...