Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Synthetic aperture imaging in acoustic microscopy

View through CrossRef
Acoustic microscopy (AM) provides micro-meter resolution using a highly focused single-element transducer. A drawback in AM is a relatively small depth of field, resulting in poor resolution outside the focus. Synthetic aperature focusing technique (SAFT) can be used to improve the image resolution throughout the field of view. SAFT mathematically synthesizes the effect of an array transducer and produces dynamic focusing and depth-independent resolution. SAFT in time domain with and without apodization, TD-SAFT and ATD-SAFT, respectively, and in frequency domain (FD-SAFT) were implemented and tested using simulated and experimental radio-frequency data from an acoustic microscope at 400 MHz. Lateral resolution of all the SAFT reconstructed images were better than those of the conventional B-mode images. While TD-SAFT and FD-SAFT permformed better than ATD-SAFT in improving the lateral resolution, ATD-SAFT provided lower side lobes. In conclusion, SAFT improves resolution in AM outside the focal region.
Ryerson University Library and Archives
Title: Synthetic aperture imaging in acoustic microscopy
Description:
Acoustic microscopy (AM) provides micro-meter resolution using a highly focused single-element transducer.
A drawback in AM is a relatively small depth of field, resulting in poor resolution outside the focus.
Synthetic aperature focusing technique (SAFT) can be used to improve the image resolution throughout the field of view.
SAFT mathematically synthesizes the effect of an array transducer and produces dynamic focusing and depth-independent resolution.
SAFT in time domain with and without apodization, TD-SAFT and ATD-SAFT, respectively, and in frequency domain (FD-SAFT) were implemented and tested using simulated and experimental radio-frequency data from an acoustic microscope at 400 MHz.
Lateral resolution of all the SAFT reconstructed images were better than those of the conventional B-mode images.
While TD-SAFT and FD-SAFT permformed better than ATD-SAFT in improving the lateral resolution, ATD-SAFT provided lower side lobes.
In conclusion, SAFT improves resolution in AM outside the focal region.

Related Results

Subjective audiometric measures in individuals with repeated acoustic trauma in the combat zone
Subjective audiometric measures in individuals with repeated acoustic trauma in the combat zone
Intense sound exposure that exceeds the pain threshold of human auditory sensitivity, known as acoustic trauma, causes significant and extensive changes in the auditory system. Thr...
Spaceborne Synthetic Aperture Passive Imaging Technology for Wide-Area Electromagnetic Spectrum Map Generati
Spaceborne Synthetic Aperture Passive Imaging Technology for Wide-Area Electromagnetic Spectrum Map Generati
Current space-based electromagnetic spectrum sensing and imaging methods suffer from several limitations, including inadequate acquisition and characterization of holistic situatio...
Coherent Beam Steering via a Synthetic-Aperture Integrated Waveguide Grating Antenna
Coherent Beam Steering via a Synthetic-Aperture Integrated Waveguide Grating Antenna
The waveguide grating antenna serves as the optical-frequency counterpart of radio-frequency phased array, enabling high-speed beam steering in a fully solid-state form. It offers ...
Noise-resistant and aberration-free synthetic aperture digital holographic microscopy for chip topography reconstruction
Noise-resistant and aberration-free synthetic aperture digital holographic microscopy for chip topography reconstruction
Phase aberration introduced by an optical system and phase noise caused by parasitic fringes are crucial issues that limit the quality of the reconstructed super-resolution phase i...
Modelling Unconventional Velocities from Acoustic Microscope Measurements
Modelling Unconventional Velocities from Acoustic Microscope Measurements
Abstract We use integrated micro-CT, thin section, XRF, SEM, and acoustic microscopy to quantify the controls on the acoustic properties of source rock reservoirs. A...
Modeling and evaluation of performance of dual field-of-view common-aperture dual-band imaging system
Modeling and evaluation of performance of dual field-of-view common-aperture dual-band imaging system
For the modeling and evaluation of dual field-of-view (FOV) common-aperture dual-band imaging system performance, two factors must be considered at the same time. One is that the s...
Applications Of Acoustic Image Logs
Applications Of Acoustic Image Logs
Abstract Acoustic image logs have been acquired in the Barua/Motatan and Mara fields as a part of the information acquisition program implemented by Maraven, S.A....
Multi‐Photon Microscopy
Multi‐Photon Microscopy
AbstractIn this series of papers on light microscopy imaging, we have covered the fundamentals of microscopy, super‐resolution microscopy, and lightsheet microscopy. This last revi...

Back to Top