Javascript must be enabled to continue!
Semi Nulling Calibration of a Five Hole Probe
View through CrossRef
Five hole probes are extensively used for measuring three dimensional flows. However the useful range of the probe is limited to about ± 30°. In many flows, this range may be exceeded. In such flows, a seven hole or even a nine hole probe is required increasing testing time or using alternative methods. The objective of the present paper is to find one such alternative method for use of five hole probes in highly three dimensional flows. A large size probe is manufactured and calibrated in an open jet calibration tunnel at a velocity of 40 m/s in yaw angle range of ±90° and pitch angle range of -70° to 90° at an interval of 10°. The probe calibration data is used for nulling calibration with zero yaw angle and pitch angle range of about ± 70°. This method is time consuming. Hence a semi nulling calibration method is developed. This method is similar to non-nulling calibration method. However the range of yaw angle is limited to ± 20°. If the flow yaw angle exceeds this yaw angle range, the probe can be rotated, so that the probe can be used to measure flows with large yaw and pitch angles. The calibration curves of semi nulling method are compared with those of zonal non nulling calibration method. It is found that the pitch angle range of non nulling calibration method is one pitch angle interval less than that of semi nulling method.
Title: Semi Nulling Calibration of a Five Hole Probe
Description:
Five hole probes are extensively used for measuring three dimensional flows.
However the useful range of the probe is limited to about ± 30°.
In many flows, this range may be exceeded.
In such flows, a seven hole or even a nine hole probe is required increasing testing time or using alternative methods.
The objective of the present paper is to find one such alternative method for use of five hole probes in highly three dimensional flows.
A large size probe is manufactured and calibrated in an open jet calibration tunnel at a velocity of 40 m/s in yaw angle range of ±90° and pitch angle range of -70° to 90° at an interval of 10°.
The probe calibration data is used for nulling calibration with zero yaw angle and pitch angle range of about ± 70°.
This method is time consuming.
Hence a semi nulling calibration method is developed.
This method is similar to non-nulling calibration method.
However the range of yaw angle is limited to ± 20°.
If the flow yaw angle exceeds this yaw angle range, the probe can be rotated, so that the probe can be used to measure flows with large yaw and pitch angles.
The calibration curves of semi nulling method are compared with those of zonal non nulling calibration method.
It is found that the pitch angle range of non nulling calibration method is one pitch angle interval less than that of semi nulling method.
Related Results
(Invited) Strategies for Calibration Cost Reduction in Heterogeneous Chemical Sensor Arrays
(Invited) Strategies for Calibration Cost Reduction in Heterogeneous Chemical Sensor Arrays
Introduction
Heterogeneous gas sensor arrays coupled with machine learning algorithms have been proposed for a wide range of applications. However, i...
Numerical Investigation of the Reynolds Number Effect on Five-Hole Probe Calibration
Numerical Investigation of the Reynolds Number Effect on Five-Hole Probe Calibration
Five-hole probes are widely used in turbomachinery applications. However, the Reynolds number dependence of the probe calibration has not received enough attention. The experimenta...
Magnetic Resonance Imaging in Cardiac Amyloidosis: Unraveling the Stealth Entity
Magnetic Resonance Imaging in Cardiac Amyloidosis: Unraveling the Stealth Entity
AbstractAmyloidosis is a systemic disease involving many organs. Cardiac involvement is a significant cause of morbidity and mortality in these patients. Diagnosis of cardiac amylo...
Virtual four sensor fast response aerodynamic probe (FRAP®)
Virtual four sensor fast response aerodynamic probe (FRAP®)
This paper introduces the new fast response aerodynamic probe (FRAP®), which was recently developed at the ETH Zurich. The probe provides time-resolved, three-dimensional flow meas...
Radiometric cross-calibration of Sentinel-2B MSI with HY-1C SCS based on the near simultaneous imaging of common ground targets
Radiometric cross-calibration of Sentinel-2B MSI with HY-1C SCS based on the near simultaneous imaging of common ground targets
To simplify the cross-calibration process and improve calibration frequency and accuracy, this paper proposes a cross-calibration method for the multispectral remote sensor Multi-S...
Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
EnvironmentalSurveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) This comprehensive protocol suite enables systematic environmental surveillance for avian influenza...
Automatic Hand-Eye Calibration Method of Welding Robot Based on Linear Structured Light
Automatic Hand-Eye Calibration Method of Welding Robot Based on Linear Structured Light
Aiming at solving the problems such as long calibration time, low precision, and complex operation in hand-eye calibration of welding robot, an automatic hand-eye calibration algor...
A Probabilistic Belief System to Track the Cleanliness of a Hole in Real-Time
A Probabilistic Belief System to Track the Cleanliness of a Hole in Real-Time
Abstract
Good hole cleaning is essential to maintaining drilling efficiency and preventing non-productive events such as stuck pipe during well construction operatio...

