Javascript must be enabled to continue!
Diagnostic Value of Troponin T in Neonates of Mild Pre-Eclamptic Mothers
View through CrossRef
The measurement of myocardial damage by newer, highly specific markers of myocardial damage is now possible, including cardiac structural proteins such as troponin T (TnT). In neonates of pre-eclamptic mothers, it identifies minor myocardial damage missed by other biochemical markers. The present study was designed to determine the diagnostic value of TnT concentrations in neonates of pre-eclamptic mothers. Fifteen neonates of pre-eclamptic mothers were studied (9 boys and 6 girls), and 17 healthy full-term neonates (9 boys and 8 girls) were selected as a control group. The serum TnT concentration in neonates of pre-eclamptic mothers (0.70 ng/ml) was significantly higher than that in the control group (0.10 ng/ml). In an echocardiographic study, the mean mitral peak velocity at an atrial contraction (A) value of 39 cm/s in neonates of pre-eclamptic mothers was significantly lower than that in the control group (53 cm/s), and the mean mitral peak velocity of early diastole to peak velocity of the atrial contraction (E/A) value (1.75) in neonates of pre-eclamptic mothers was significantly higher than that in the control subjects (1.23). In conclusion, our study demonstrated high levels of cardiac TnT, lower mitral A values and high mitral E/A values in neonates of pre-eclamptic mothers, presumably associated with mild myocardial damage in the neonates of pre-eclamptic mothers.
Title: Diagnostic Value of Troponin T in Neonates of Mild Pre-Eclamptic Mothers
Description:
The measurement of myocardial damage by newer, highly specific markers of myocardial damage is now possible, including cardiac structural proteins such as troponin T (TnT).
In neonates of pre-eclamptic mothers, it identifies minor myocardial damage missed by other biochemical markers.
The present study was designed to determine the diagnostic value of TnT concentrations in neonates of pre-eclamptic mothers.
Fifteen neonates of pre-eclamptic mothers were studied (9 boys and 6 girls), and 17 healthy full-term neonates (9 boys and 8 girls) were selected as a control group.
The serum TnT concentration in neonates of pre-eclamptic mothers (0.
70 ng/ml) was significantly higher than that in the control group (0.
10 ng/ml).
In an echocardiographic study, the mean mitral peak velocity at an atrial contraction (A) value of 39 cm/s in neonates of pre-eclamptic mothers was significantly lower than that in the control group (53 cm/s), and the mean mitral peak velocity of early diastole to peak velocity of the atrial contraction (E/A) value (1.
75) in neonates of pre-eclamptic mothers was significantly higher than that in the control subjects (1.
23).
In conclusion, our study demonstrated high levels of cardiac TnT, lower mitral A values and high mitral E/A values in neonates of pre-eclamptic mothers, presumably associated with mild myocardial damage in the neonates of pre-eclamptic mothers.
Related Results
Additional PKA phosphorylation sites in human cardiac troponin I
Additional PKA phosphorylation sites in human cardiac troponin I
We used mass spectrometry to monitor cAMP‐dependent protein kinase catalysed phosphorylation of human cardiac troponin I in vitro. Phosphorylation of isolated troponin I by cAMP‐de...
Phosphorylation of troponin and the effects of interactions between the components of the complex
Phosphorylation of troponin and the effects of interactions between the components of the complex
1. The troponin complex from skeletal muscle contains approximately 1 mol of phosphate/80000g of complex, covalently bound to the troponin T component. 2. On prolonged incubation o...
Structural dynamics of the intrinsically disordered linker region of cardiac troponin T
Structural dynamics of the intrinsically disordered linker region of cardiac troponin T
ABSTRACT
The cardiac troponin complex, composed of troponins I, T, and C, plays a central role in regulating the calcium-dependent interactions between myosin and t...
Impairment of Liver Function in Pre-Eclamptic Patients in North East Medical College Hospital
Impairment of Liver Function in Pre-Eclamptic Patients in North East Medical College Hospital
Abstract
This study was conducted to see the change of liver function in preeclampsia in comparison to normal pregnancy. This cross-sectional comparative study was conducted in the...
Antiphospholipid Antibodies in Eclamptic Women
Antiphospholipid Antibodies in Eclamptic Women
Our purpose was to determine the prevalence of antiphospholipid antibodies (APA) in eclamptic women as well as the rates of intrauterine growth retardation (IUGR) and fetal death i...
Misleading Elevation of Troponin T caused by Polymyositis
Misleading Elevation of Troponin T caused by Polymyositis
Background: Elevations of cardiac enzymes are commonly used to indicate myocardial ischemia, but they can be elevated due to other conditions. Different forms of Troponin (cTnT, sT...
The phosphorylation of troponin I from cardiac muscle
The phosphorylation of troponin I from cardiac muscle
1. Troponin I isolated from fresh cardiac muscle by affinity chromatography contains about 1.9 mol of covalently bound phosphate/mol. Similar preparations of white-skeletal-muscle ...
Analysis of the causes of discrepancies in troponin I concentrations as measured by ARCHITECT High-Sensitive Troponin I ST and STACIA CLEIA cTnI
Analysis of the causes of discrepancies in troponin I concentrations as measured by ARCHITECT High-Sensitive Troponin I ST and STACIA CLEIA cTnI
Background
Recently developed reagents for the highly sensitive measurement of cardiac troponin I are useful for early diagnosis of acute coronary syndrome. How...

