SU‐FF‐I‐111: Feasibility of Using Higher Energy Beam Pairs to Improve DXA Accuracy
View through CrossRef
In standard DXA the fat content of the soft tissue containing the bone is assumed to be the same as the soft tissue in the baseline region of the scan adjacent to the bone. Unfortunately, this assumption is rarely correct and inaccuracies in BMD can exceed 20 % in clinically realistic cases. Moreover, changes in fat content resulting from weight loss or gain makes interpretation of changes seen in BMD problematic. The cause of the inaccuracy is the large difference in the attenuation characteristics of fat and lean tissues at the effective energy of the low energy beam used in standard DXA. A mathematical simulation of DXA using monoenergetic photon beams was performed using beam energy pairs higher than used for standard DXA. In the simulation the low energy beam was varied from 80 to 110 keV with the high energy beam held constant at 140 keV. The entrance doses of the simulations were varied to maintain a measurement precision equivalent to that of standard DXA. For simulated DXA using higher beam energy pairs the BMD error due to inhomogeneities in the fat content of soft tissue was eliminated. The entrance skin dose for the higher energy beam pairs needed to be increased to achieve the same measurement precision as standard DXA.Thus, the accuracy of BMD measurements can be improved by using higher energy beam pairs with a modest increase in entrance dose. This improvement in accuracy allows the accurate assessment of BMD changes in patients experiencing weight change.
Title: SU‐FF‐I‐111: Feasibility of Using Higher Energy Beam Pairs to Improve DXA Accuracy
Description:
In standard DXA the fat content of the soft tissue containing the bone is assumed to be the same as the soft tissue in the baseline region of the scan adjacent to the bone.
Unfortunately, this assumption is rarely correct and inaccuracies in BMD can exceed 20 % in clinically realistic cases.
Moreover, changes in fat content resulting from weight loss or gain makes interpretation of changes seen in BMD problematic.
The cause of the inaccuracy is the large difference in the attenuation characteristics of fat and lean tissues at the effective energy of the low energy beam used in standard DXA.
A mathematical simulation of DXA using monoenergetic photon beams was performed using beam energy pairs higher than used for standard DXA.
In the simulation the low energy beam was varied from 80 to 110 keV with the high energy beam held constant at 140 keV.
The entrance doses of the simulations were varied to maintain a measurement precision equivalent to that of standard DXA.
For simulated DXA using higher beam energy pairs the BMD error due to inhomogeneities in the fat content of soft tissue was eliminated.
The entrance skin dose for the higher energy beam pairs needed to be increased to achieve the same measurement precision as standard DXA.
Thus, the accuracy of BMD measurements can be improved by using higher energy beam pairs with a modest increase in entrance dose.
This improvement in accuracy allows the accurate assessment of BMD changes in patients experiencing weight change.
Related Results
3727 Addressing inequities in dual-energy x-ray absorptiometry (DXA) access: a multi-dimensional quality improvement approach
3727 Addressing inequities in dual-energy x-ray absorptiometry (DXA) access: a multi-dimensional quality improvement approach
Abstract
Introduction
Dual-energy X-ray absorptiometry (DXA) is the gold standard for diagnosing osteoporosis and guiding...
ECG CLASSIFICATION COMPARISON BETWEEN MF-DFA AND MF-DXA
ECG CLASSIFICATION COMPARISON BETWEEN MF-DFA AND MF-DXA
In this paper, automatic electrocardiogram (ECG) recognition and classification algorithms based on multifractal detrended fluctuation analysis (MF-DFA) and multifractal detrended ...
Trapezium Bone Density—A Comparison of Measurements by DXA and CT
Trapezium Bone Density—A Comparison of Measurements by DXA and CT
Bone density may influence the primary fixation of cementless implants, and poor bone density may increase the risk of implant failure. Before deciding on using total joint replace...
A novel classifier of radiographic knee osteoarthritis for use on knee DXA images is predictive of joint replacement in UK Biobank
A novel classifier of radiographic knee osteoarthritis for use on knee DXA images is predictive of joint replacement in UK Biobank
AbstractObjectivesDXA scans may offer a novel means of evaluating radiographic knee osteoarthritis (rKOA) in large population studies and through opportunistic screening. We aimed ...
Analisis Numerik Kuat Lentur Balok Support Beam Curve Tile Beton Semi Pracetak Dengan Variasi Panjang Bentangan
Analisis Numerik Kuat Lentur Balok Support Beam Curve Tile Beton Semi Pracetak Dengan Variasi Panjang Bentangan
Semi precast slab is a combination of precast concrete which consist of the support beam and curve tile with the cast in place concrete. During the working process, support beam wi...
MO810: Hypocalcaemia Associated with Denosumab Antiresorptive Therapy is Independent of Bone Turnover Biomarkers
MO810: Hypocalcaemia Associated with Denosumab Antiresorptive Therapy is Independent of Bone Turnover Biomarkers
Abstract
BACKGROUND AND AIMS
Background: The incidence of major fractures is increased in the setting of haemodialysis patients....
Vævning over gruber
Vævning over gruber
Pits, Looms, and Loom Pits? In the archaeological quarterly Skalk (1959, no 2), Mogens Ørsnes described "The Problem of the Hundred Holes," pits "large and small, shallow and deep"...
Funkcije komunikacijski relevantne šutnje u njemačkome
Funkcije komunikacijski relevantne šutnje u njemačkome
Additionally, this chapter presents research of silence with review of main aspects of papers in the field of conversational analysis, ethnography of communication and metaphor of ...