Cement Selection for Implant‐Supported Crowns Fabricated with Different Luting Space Settings

View through CrossRef
AbstractPurpose: To measure and compare the retentive strength of cements specifically formulated for luting restorations onto implant abutments and to investigate the effect of varying cement gap on retention strength of implant‐supported crowns.Materials and Methods: Standard titanium abutments were scanned by means of a 3D digital laser scanner. One hundred and sixty standard metal copings were designed by a Computer Aided Design/Computer Aided Manufacturing (CAD/CAM) system with two cement gap values (20 and 40 μm). The copings were cemented to the abutments using the following eight cements with one being the control, zinc oxide temporary cement, while the other seven were specifically formulated implant cements (n = 10): Premier Implant Cement, ImProv, Multilink Implant, EsTemp Implant, Cem‐Implant, ImplaTemp, MIS Crown Set, and TempBond NE. The specimens were placed in 100% humidity for 24 hours, and subjected to a pull‐out test using a universal testing machine at a 0.5 mm/min crosshead speed. The test results were analyzed with two‐way ANOVA, one‐way ANOVA, post hoc Tamhane’ s T2, and student's t‐tests at a significance level of 0.05.Results: Statistical analysis revealed significant differences in retention strength across the cement groups (p < 0.01). Resin‐based cements showed significantly higher decementation loads than a noneugenol zinc oxide provisional cement (TempBond NE) (p < 0.01), with the highest tensile resistance seen with Multilink Implant, followed by Cem‐Implant, MIS Crown Set, ImProv, Premier Implant Cement, EsTemp Implant, and ImplaTemp. Increasing the cement gap from 20 to 40 μm improved retention significantly for the higher strength cements: Multilink Implant, Premier Implant Cement, ImProv, Cem‐Implant, and MIS Crown Set (p < 0.01), while it had no significant effect on retention for the lower strength cements: EsTemp Implant, ImplaTemp, and TempBond NE (p > 0.05).Conclusions: Resin cements specifically formulated for implant‐supported restorations demonstrated significant differences in retention strength. The ranking of cements presented in the study is meant to be an arbitrary guide for the clinician in deciding the appropriate cement selection for CAD/CAM‐fabricated metal copings onto implant abutments with different luting space settings.
Title: Cement Selection for Implant‐Supported Crowns Fabricated with Different Luting Space Settings
Description:
AbstractPurpose: To measure and compare the retentive strength of cements specifically formulated for luting restorations onto implant abutments and to investigate the effect of varying cement gap on retention strength of implant‐supported crowns.
Materials and Methods: Standard titanium abutments were scanned by means of a 3D digital laser scanner.
One hundred and sixty standard metal copings were designed by a Computer Aided Design/Computer Aided Manufacturing (CAD/CAM) system with two cement gap values (20 and 40 μm).
The copings were cemented to the abutments using the following eight cements with one being the control, zinc oxide temporary cement, while the other seven were specifically formulated implant cements (n = 10): Premier Implant Cement, ImProv, Multilink Implant, EsTemp Implant, Cem‐Implant, ImplaTemp, MIS Crown Set, and TempBond NE.
The specimens were placed in 100% humidity for 24 hours, and subjected to a pull‐out test using a universal testing machine at a 0.
5 mm/min crosshead speed.
The test results were analyzed with two‐way ANOVA, one‐way ANOVA, post hoc Tamhane’ s T2, and student's t‐tests at a significance level of 0.
05.
Results: Statistical analysis revealed significant differences in retention strength across the cement groups (p < 0.
01).
Resin‐based cements showed significantly higher decementation loads than a noneugenol zinc oxide provisional cement (TempBond NE) (p < 0.
01), with the highest tensile resistance seen with Multilink Implant, followed by Cem‐Implant, MIS Crown Set, ImProv, Premier Implant Cement, EsTemp Implant, and ImplaTemp.
Increasing the cement gap from 20 to 40 μm improved retention significantly for the higher strength cements: Multilink Implant, Premier Implant Cement, ImProv, Cem‐Implant, and MIS Crown Set (p < 0.
01), while it had no significant effect on retention for the lower strength cements: EsTemp Implant, ImplaTemp, and TempBond NE (p > 0.
05).
Conclusions: Resin cements specifically formulated for implant‐supported restorations demonstrated significant differences in retention strength.
The ranking of cements presented in the study is meant to be an arbitrary guide for the clinician in deciding the appropriate cement selection for CAD/CAM‐fabricated metal copings onto implant abutments with different luting space settings.

Related Results

Original Research Article Effect of Radiotherapy on Flexural Strength of Luting Cementsan In Vitro Study
Original Research Article Effect of Radiotherapy on Flexural Strength of Luting Cementsan In Vitro Study
Aim - The aim of this study was to evaluate changes in the flexural strength of luting cements due to radiotherapy. Methodology- Total of 90 rectangular specimens of 25×2×2 mm dime...
The cement-bone bond is weaker than cement-cement bond in cement-in-cement revision arthroplasty. A comparative biomechanical study
The cement-bone bond is weaker than cement-cement bond in cement-in-cement revision arthroplasty. A comparative biomechanical study
This study compares the strength of the native bone-cement bond and the old-new cement bond under cyclic loading, using third generation cementing technique, rasping and contaminat...
ELECTRICAL RESISTANCE OF DENTAL LUTING CEMENTS INVESTIGATED BY IMPEDANCE METHODOLOGY RELATED TO THEIR POROSITIES AND SOLUBILITY
ELECTRICAL RESISTANCE OF DENTAL LUTING CEMENTS INVESTIGATED BY IMPEDANCE METHODOLOGY RELATED TO THEIR POROSITIES AND SOLUBILITY
The electrical resistance property of dental cement is one of important physical properties. Most previous studies aimed to investigate the mechanical properties, solubility and es...
Real-Time Distributed Fiber Optic Sensing for Cement Sheath Integrity Monitoring
Real-Time Distributed Fiber Optic Sensing for Cement Sheath Integrity Monitoring
ABSTRACT: The integrity of cement sheath is critical to oil and gas effective extraction, in which the cement displacement efficiency and solidify quality are the...
FLY ASH FOUNDATION REINFORCED BY CEMENT–SOIL MIXING PILES
FLY ASH FOUNDATION REINFORCED BY CEMENT–SOIL MIXING PILES
Cement-soil mixing piles have been commonly used to enhance the bearing capacity of fly ash stratum and mitigate the settlement damage to the surrounding environment. However, only...

Back to Top