Javascript must be enabled to continue!
Home Mechanical Ventilation through Mask: Monitoring Leakage and Nocturnal Oxygenation at Home
View through CrossRef
<b><i>Background:</i></b> Leakage is common in patients receiving home mechanical ventilation (HMV) via a face mask. Although pressure ventilators have partial compensatory capacity, excessive leakage can compromise the effectiveness of treatment. Home ventilators are equipped with built-in software which provides information on leakage. However, the values of leakage and their effects in routine clinical practice are currently little known. <b><i>Objective:</i></b> To measure leakage in stable patients on nocturnal HMV and its impact on treatment effectiveness. <b><i>Methods:</i></b> Consecutive outpatients on HMV were recruited. Nocturnal pulse oximetry was performed at home and leakage was measured using the ventilator’s built-in software. We measured: mean Sp<smlcap>O</smlcap><sub>2</sub>, percentage of time with Sp<smlcap>O</smlcap><sub>2</sub> <90% (T90), mean leakage (meanL), maximum leakage (maxL), and minimum leakage (minL) during the ventilation session. We estimated ventilator capacity to compensate for leakage according to inspiratory positive airway pressure and divided the patients into two groups: those with leak compensation and those without. <b><i>Results:</i></b> The study included 41 patients [mean age, 64 years (SD 11.9); 23 (56%) women]. Nocturnal pulse oximetry showed an Sp<smlcap>O</smlcap><sub>2</sub> of 94% (±2.9) and a T90 of 10% (±21.7). Leakage (in l/min) was: meanL, 32.2 (±15.3); maxL, 64.8 (±28.5), and minL, 18.8 (±10.6). Seven cases (17%) had leakage greater than the ventilator compensatory capacity, but no significant difference in Sp<smlcap>O</smlcap><sub>2</sub> or T90 was observed between patients with or without leak compensation. <b><i>Conclusions:</i></b> A wide variation between maxL and minL was observed in our series; 17% of cases had higher leakage values than the compensatory capacity of the ventilator, but this did not affect nocturnal oxygenation.
Title: Home Mechanical Ventilation through Mask: Monitoring Leakage and Nocturnal Oxygenation at Home
Description:
<b><i>Background:</i></b> Leakage is common in patients receiving home mechanical ventilation (HMV) via a face mask.
Although pressure ventilators have partial compensatory capacity, excessive leakage can compromise the effectiveness of treatment.
Home ventilators are equipped with built-in software which provides information on leakage.
However, the values of leakage and their effects in routine clinical practice are currently little known.
<b><i>Objective:</i></b> To measure leakage in stable patients on nocturnal HMV and its impact on treatment effectiveness.
<b><i>Methods:</i></b> Consecutive outpatients on HMV were recruited.
Nocturnal pulse oximetry was performed at home and leakage was measured using the ventilator’s built-in software.
We measured: mean Sp<smlcap>O</smlcap><sub>2</sub>, percentage of time with Sp<smlcap>O</smlcap><sub>2</sub> <90% (T90), mean leakage (meanL), maximum leakage (maxL), and minimum leakage (minL) during the ventilation session.
We estimated ventilator capacity to compensate for leakage according to inspiratory positive airway pressure and divided the patients into two groups: those with leak compensation and those without.
<b><i>Results:</i></b> The study included 41 patients [mean age, 64 years (SD 11.
9); 23 (56%) women].
Nocturnal pulse oximetry showed an Sp<smlcap>O</smlcap><sub>2</sub> of 94% (±2.
9) and a T90 of 10% (±21.
7).
Leakage (in l/min) was: meanL, 32.
2 (±15.
3); maxL, 64.
8 (±28.
5), and minL, 18.
8 (±10.
6).
Seven cases (17%) had leakage greater than the ventilator compensatory capacity, but no significant difference in Sp<smlcap>O</smlcap><sub>2</sub> or T90 was observed between patients with or without leak compensation.
<b><i>Conclusions:</i></b> A wide variation between maxL and minL was observed in our series; 17% of cases had higher leakage values than the compensatory capacity of the ventilator, but this did not affect nocturnal oxygenation.
Related Results
Contribution of Transcutaneous P
CO
2
in Obesity Hypoventilation Syndrome
Contribution of Transcutaneous P
CO
2
in Obesity Hypoventilation Syndrome
BACKGROUND:
Increasing numbers of patients have obesity-hypoventilation syndrome (OHS) because of the increasing prevalence of obesity. T...
Impact clinique des techniques non-invasives d'oxygénation au cours de l'insuffisance respiratoire aiguë
Impact clinique des techniques non-invasives d'oxygénation au cours de l'insuffisance respiratoire aiguë
L’oxygénothérapie conventionnelle, l’oxygénothérapie nasale à haut débit (OHD, et la ventilation non-invasive (VNI), sont les trois techniques d’oxygénation disponibles en réanimat...
P275 Uncontrolled post-clinic blood pressure readings can identify nocturnal non-dipping blood pressure pattern
P275 Uncontrolled post-clinic blood pressure readings can identify nocturnal non-dipping blood pressure pattern
Abstract
Funding Acknowledgements
Aga Khan University Faculty of Health Sciences Research Committee (#80096)
...
Multiple Water and Sand Leakage Model Tests for Shield Tunnels
Multiple Water and Sand Leakage Model Tests for Shield Tunnels
Water and sand leakage in shield tunnels has become more of a research interest in recent years. On the other hand, accidents involving underground engineering can take many forms ...
Prostor doma u hrvatskim igranim filmovima s temom domovinskog rata
Prostor doma u hrvatskim igranim filmovima s temom domovinskog rata
The dissertation explores the formation of domestic space in contemporary Croatian society through its presentations in the medium of feature films. The cinematic domestic spaces a...
TU‐H‐202‐02: Applications, Validation, Clinical Endpoints and Opportunities for CT Ventilation
TU‐H‐202‐02: Applications, Validation, Clinical Endpoints and Opportunities for CT Ventilation
CT ventilation imaging is an exciting functional imaging modality that combines four‐dimensional computed tomography (4DCT) and deformable image registration (DIR) to provide exqui...
Invasive Mechanical Ventilation Duration Prediction using Survival Analysis
Invasive Mechanical Ventilation Duration Prediction using Survival Analysis
Abstract
Invasive mechanical ventilation is one of the leading life support machines in the intensive care unit (ICU). By identifying the predictors of ventilation ...
Safety Research on Hydrogen Leakage of Hydrogen Storage Equipment in Integrated Hydrogen Energy Storage Station Based on Photovoltaic Power Generation
Safety Research on Hydrogen Leakage of Hydrogen Storage Equipment in Integrated Hydrogen Energy Storage Station Based on Photovoltaic Power Generation
Against the background of the “dual carbon” goals and the integration of a high proportion of renewable energy, hydrogen energy storage, with its advantages of long duration and la...

