Javascript must be enabled to continue!
Air Heat Pump in Wind Power
View through CrossRef
An experimental facility has been developed and manufactured to study the disruptive flow in an air heat pump. The propeller of the heat pump does not produce pulling or pushing forces. The external air flow is created by a high speed propeller perpendicular to the plane of rotation of the heat pump propeller and acts as a ventilator. Herewith, a disruptive flow in the back side of the heat pump propeller is being created and conditions for converting the thermal component of the ventilator air flow into electrical energy by an electric power generator are realized. An aerodynamic model of the flow around the propeller blades of the heat pump in mutually perpendicular airflow has been developed. Experimental studies of the operating propeller as a heat pump, taking into account the friction during rotation of the rotor in the stator of the electric generator, were carried out. In order for the air heat pump to perceive the impacting air flow from the ventilator, it must rotate with minimal power. As a result, for two standard twin-bladed propellers mounted on a 100 W engine under the wind generated by the ventilator which speed is 2.17 m/s the conversion factor was 5.04. As the speed of air flow from the ventilator increased, the conversion coefficient decreased sharply. When placing the two specified propellers on a 300 W motor, the minimum pre-rotation power was 5.7 W. In this case, when an air flow speed is of 1.08 m/s, the conversion coefficient reached only 2.93 and also fell sharply with the increase in the air flow speed. When a three-blade propeller with blades was used on a 300 W motor, then situation has changed dramatically. When the motor with a special propeller with a power of 12.1 W was spun and the air flow was formed at a speed of 3.2 m/s, the conversion coefficient was 12.4. With the reduction in the power of the spinup down to 5.9 W and in the speed of the air flow created by the ventilator to 1.7 m/s, the conversion coefficient increased to 14.9. The theoretical calculation of heat pump conversion coefficient is confirmed by experimental data. The conditions under which this coefficient reaches its maximum value are set. Computer modeling of different designs of heat pump propeller blades was performed. It is demonstrated that an air heat pump is a complex open energy system.
Belarusian National Technical University
Title: Air Heat Pump in Wind Power
Description:
An experimental facility has been developed and manufactured to study the disruptive flow in an air heat pump.
The propeller of the heat pump does not produce pulling or pushing forces.
The external air flow is created by a high speed propeller perpendicular to the plane of rotation of the heat pump propeller and acts as a ventilator.
Herewith, a disruptive flow in the back side of the heat pump propeller is being created and conditions for converting the thermal component of the ventilator air flow into electrical energy by an electric power generator are realized.
An aerodynamic model of the flow around the propeller blades of the heat pump in mutually perpendicular airflow has been developed.
Experimental studies of the operating propeller as a heat pump, taking into account the friction during rotation of the rotor in the stator of the electric generator, were carried out.
In order for the air heat pump to perceive the impacting air flow from the ventilator, it must rotate with minimal power.
As a result, for two standard twin-bladed propellers mounted on a 100 W engine under the wind generated by the ventilator which speed is 2.
17 m/s the conversion factor was 5.
04.
As the speed of air flow from the ventilator increased, the conversion coefficient decreased sharply.
When placing the two specified propellers on a 300 W motor, the minimum pre-rotation power was 5.
7 W.
In this case, when an air flow speed is of 1.
08 m/s, the conversion coefficient reached only 2.
93 and also fell sharply with the increase in the air flow speed.
When a three-blade propeller with blades was used on a 300 W motor, then situation has changed dramatically.
When the motor with a special propeller with a power of 12.
1 W was spun and the air flow was formed at a speed of 3.
2 m/s, the conversion coefficient was 12.
4.
With the reduction in the power of the spinup down to 5.
9 W and in the speed of the air flow created by the ventilator to 1.
7 m/s, the conversion coefficient increased to 14.
9.
The theoretical calculation of heat pump conversion coefficient is confirmed by experimental data.
The conditions under which this coefficient reaches its maximum value are set.
Computer modeling of different designs of heat pump propeller blades was performed.
It is demonstrated that an air heat pump is a complex open energy system.
Related Results
Wind lidars within Dutch offshore wind farms
Wind lidars within Dutch offshore wind farms
The growing number of wind farms in the Dutch part of the North Sea [1] offers the necessity, as well as the opportunity, to measure the meteorological conditions at these location...
Performance Test and Simulation Study on the Air Path of CAP1400 Passive Containment Cooling System
Performance Test and Simulation Study on the Air Path of CAP1400 Passive Containment Cooling System
As a large scale passive pressurized water reactor nuclear power plant, CAP1400 can remove the reactor decay heat to outside containment with the air cooling in the air flow path o...
Analysis of Senegal Type Vertical Axis Wind Turbines Arrangement in Wind Farm
Analysis of Senegal Type Vertical Axis Wind Turbines Arrangement in Wind Farm
Background:
In a wind farm, the wind speed of the downstream wind turbine will be
lower than the wind speed of the upstream wind turbine due to the influence of the wake. Therefore...
Large Scale PWR Passive Containment Cooling System Wind Tunnel Test
Large Scale PWR Passive Containment Cooling System Wind Tunnel Test
CAP1400 is a large passive pressurized water reactor nuclear power plant, which relies on engineering safety features such as passive containment cooling system (PCS) to remove the...
Savonius Rotor for Offshore Wind Energy Conversion
Savonius Rotor for Offshore Wind Energy Conversion
Abstract
Analysis of performance is presented for wind energy conversion by a Savonius type vertical axis rotor configured for generation of electrical power. The...
Solar wind interaction with comet 67P around perihelion
Solar wind interaction with comet 67P around perihelion
AbstractNear perihelion, when comet 67P was most active, the Rosetta spacecraft resided inside the comet induced magnetosphere. The solar wind magnetic field was still present, but...
Modeling of the dynamics of wind to power conversion including high wind speed behavior
Modeling of the dynamics of wind to power conversion including high wind speed behavior
AbstractThis paper proposes and validates an efficient, generic and computationally simple dynamic model for the conversion of the wind speed at hub height into the electrical powe...
Downhole Beam Pump Operation: Slippage and Buckling Forces Transmitted to the Rod String
Downhole Beam Pump Operation: Slippage and Buckling Forces Transmitted to the Rod String
Abstract
New results for downhole beam or rod pumps, from fairly recent test data are in conflict with traditional relationships. Additional testing is in progres...

