Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Xenon doping of liquid argon in ProtoDUNE single phase

View through CrossRef
Abstract The Deep Underground Neutrino Experiment (DUNE) will be the next generation long-baseline neutrino experiment. The far detector is designed as a complex of four LAr-TPC (Liquid Argon Time Projection Chamber) modules with 17 kt of liquid argon each. The development and validation of the first far detector technology is pursued through ProtoDUNE Single Phase (ProtoDUNE-SP), a 770 t LAr-TPC at CERN Neutrino Platform. Crucial in DUNE is the photon detection system that will ensure the trigger of non-beam events — proton decay, supernova neutrino burst and BSM searches — and will improve the timing and calorimetry for neutrino beam events. Doping liquid argon with xenon is a known technique to shift the light emitted by argon (128 nm) to a longer wavelength (178 nm) to ease its detection. The largest xenon doping test ever performed in a LAr-TPC was carried out in ProtoDUNE-SP. From February to May 2020, a gradually increasing amount of xenon was injected to also compensate for the light loss due to air contamination. The response of such a large TPC has been studied using the ProtoDUNE-SP Photon Detection System (PDS) and a dedicated setup installed before the run. With the first it was possible to study the light collection efficiency with respect to the track position, while with the second it was possible to distinguish the xenon light (178 nm) from the LAr light (128 nm). The light shifting mechanism proved to be highly efficient even at small xenon concentrations (<20 ppm in mass) furthermore it allowed recovering the light quenched by pollutants. The light collection improved far from the detection plane, enhancing the photon detector response uniformity along the drift direction and confirming a longer Rayleigh scattering length for 178 nm photons, with respect to 128 nm ones. The charge collection by the TPC was monitored proving that xenon up to 20 ppm does not impact its performance.
Title: Xenon doping of liquid argon in ProtoDUNE single phase
Description:
Abstract The Deep Underground Neutrino Experiment (DUNE) will be the next generation long-baseline neutrino experiment.
The far detector is designed as a complex of four LAr-TPC (Liquid Argon Time Projection Chamber) modules with 17 kt of liquid argon each.
The development and validation of the first far detector technology is pursued through ProtoDUNE Single Phase (ProtoDUNE-SP), a 770 t LAr-TPC at CERN Neutrino Platform.
Crucial in DUNE is the photon detection system that will ensure the trigger of non-beam events — proton decay, supernova neutrino burst and BSM searches — and will improve the timing and calorimetry for neutrino beam events.
Doping liquid argon with xenon is a known technique to shift the light emitted by argon (128 nm) to a longer wavelength (178 nm) to ease its detection.
The largest xenon doping test ever performed in a LAr-TPC was carried out in ProtoDUNE-SP.
From February to May 2020, a gradually increasing amount of xenon was injected to also compensate for the light loss due to air contamination.
The response of such a large TPC has been studied using the ProtoDUNE-SP Photon Detection System (PDS) and a dedicated setup installed before the run.
With the first it was possible to study the light collection efficiency with respect to the track position, while with the second it was possible to distinguish the xenon light (178 nm) from the LAr light (128 nm).
The light shifting mechanism proved to be highly efficient even at small xenon concentrations (<20 ppm in mass) furthermore it allowed recovering the light quenched by pollutants.
The light collection improved far from the detection plane, enhancing the photon detector response uniformity along the drift direction and confirming a longer Rayleigh scattering length for 178 nm photons, with respect to 128 nm ones.
The charge collection by the TPC was monitored proving that xenon up to 20 ppm does not impact its performance.

Related Results

Physician and miracle worker. The cult of Saint Sampson the Xenodochos and his images in eastern Orthodox medieval painting
Physician and miracle worker. The cult of Saint Sampson the Xenodochos and his images in eastern Orthodox medieval painting
Saint Sampson, whose feast is celebrated on June 27, was depicted among holy physicians. However, his images were not frequent. He was usually accompanied with Saint Mokios (...
Molecular dynamics study of diffusion of xenon in water at different temperatures
Molecular dynamics study of diffusion of xenon in water at different temperatures
Molecular Dynamics simulation was performed using 2 xenon atoms as solute and 300 water molecules as solvent. We have studied the structural properties as well as transport propert...
The ProtoDUNE Photon Detection System: technology validation and performance
The ProtoDUNE Photon Detection System: technology validation and performance
Abstract DUNE is a long-baseline accelerator experiment currently in construction at Fermilab and SURF (South Dakota). The science objectives of DUNE include the sea...
Design, construction and operation of the ProtoDUNE-SP Liquid Argon TPC
Design, construction and operation of the ProtoDUNE-SP Liquid Argon TPC
Abstract The ProtoDUNE-SP detector is a single-phase liquid argon time projection chamber (LArTPC) that was constructed and operated in the CERN North Area at th...
Noble‐Gas Compounds
Noble‐Gas Compounds
AbstractNoble‐gas reactivity was discovered in 1962 when Neil Bartlett showed that xenon gas was oxidized by PtF6to XePtF6. Pursuant to his discovery, numerous xenon and krypton co...
Noble‐Gas Compounds
Noble‐Gas Compounds
AbstractNoble‐gas reactivity was discovered on March 23, 1962 when Neil Bartlett (1932–2008) showed that xenon gas was oxidized by PtF6. The product obtained by Bartlett was initia...
Xenon Neuroprotection in Experimental Stroke
Xenon Neuroprotection in Experimental Stroke
Background Xenon has been proven to be neuroprotective in experimental brain injury. The authors hypothesized that xenon would improve outcome from focal cerebral ische...
Search for dark matter using XENONnT electron recoil data
Search for dark matter using XENONnT electron recoil data
Recherche de matière noire en utilisant les données de recul électronique de XENONnT Depuis plus d'un siècle, les astronomes ont procédé à un inventaire minutieux d...

Back to Top