Javascript must be enabled to continue!
Prototype Development of Modified Roof Turbine Ventilator for Thermal Comfort Enhancement
View through CrossRef
A mechanical ventilator known as a turbine ventilator harnesses the wind to supply natural ventilation. Due to their high performance and cheap running costs, these devices are increasingly being used to ventilate areas. This study evaluated the impact of a modified turbine ventilator system on thermal comfort and airflow inside a room. The results showed that the natural ventilation system failed to meet the ASHRAE Standard 55-2020 for thermal comfort. The installation of a turbine ventilator decreases the temperature by 1.3°C but still did not meet the standards. The modified turbine ventilator system consisted of a 305 mm diameter inner 12V, 12W exhaust fan installed in a 500 mm diameter ventilator and connected to a 50W, 12V Monocrystalline Solar Panel showed the greatest improvement with a decrease in room temperature of 4.4°C, an increase in airflow, and full compliance with the ASHRAE Standard 55-2020. The study concludes that modifications to the natural ventilation system can significantly improve thermal comfort and airflow, with the modified ventilator system being the most effective solution.
Title: Prototype Development of Modified Roof Turbine Ventilator for Thermal Comfort Enhancement
Description:
A mechanical ventilator known as a turbine ventilator harnesses the wind to supply natural ventilation.
Due to their high performance and cheap running costs, these devices are increasingly being used to ventilate areas.
This study evaluated the impact of a modified turbine ventilator system on thermal comfort and airflow inside a room.
The results showed that the natural ventilation system failed to meet the ASHRAE Standard 55-2020 for thermal comfort.
The installation of a turbine ventilator decreases the temperature by 1.
3°C but still did not meet the standards.
The modified turbine ventilator system consisted of a 305 mm diameter inner 12V, 12W exhaust fan installed in a 500 mm diameter ventilator and connected to a 50W, 12V Monocrystalline Solar Panel showed the greatest improvement with a decrease in room temperature of 4.
4°C, an increase in airflow, and full compliance with the ASHRAE Standard 55-2020.
The study concludes that modifications to the natural ventilation system can significantly improve thermal comfort and airflow, with the modified ventilator system being the most effective solution.
Related Results
[RETRACTED] Rhino XL Male Enhancement v1
[RETRACTED] Rhino XL Male Enhancement v1
[RETRACTED]Rhino XL Reviews, NY USA: Studies show that testosterone levels in males decrease constantly with growing age. There are also many other problems that males face due ...
SOCIALIZATION OF THERMAL COMFORT STANDARDS AT SMKN 4 SOUTH TANGERANG
SOCIALIZATION OF THERMAL COMFORT STANDARDS AT SMKN 4 SOUTH TANGERANG
Vocational High School (SMK) is a formal education unit that provides education that prepares students to work in specific fields. Students can continue their vocational education ...
Comprehensive Calculation And Performance Analysis Of Gas Turbine Reversible Power Turbine
Comprehensive Calculation And Performance Analysis Of Gas Turbine Reversible Power Turbine
Gas turbine technology trends to be maturing now, but the problem of which not being able to reverse directly remains resolve. In the field of marine, most ships reverse by adjusta...
THE EFFECT OF THERMAL COMFORT ON THE HEALTH OF OCCUPANTS AT CITRA GRAHA HOUSING
THE EFFECT OF THERMAL COMFORT ON THE HEALTH OF OCCUPANTS AT CITRA GRAHA HOUSING
Humans mostly spend much time indoors, which is residential houses, so it is necessary to pay attention to thermal comfort because thermal comfort is closely related to health. Sim...
Study and Application of Roof Cutting Pressure Releasing Technology in Retracement Channel Roof of Halagou 12201 Working Face
Study and Application of Roof Cutting Pressure Releasing Technology in Retracement Channel Roof of Halagou 12201 Working Face
The retracement channel roof cutting (RCRC) technology can change the overburden structure actively by cutting off the roof of channel along the direction of working face tendency ...
Pull Tests as a Measure of Roof Bolt Efficiency and of Roof Bolt Design AND Roof Bolt Anchorage at Michel Colliery AND Roof Bolting Practices, Dominion Coal Company Limited, Sydney, N. S. AND Discussion - Forum on Roof Bolting AND Roof Bolting Effectivene
Pull Tests as a Measure of Roof Bolt Efficiency and of Roof Bolt Design AND Roof Bolt Anchorage at Michel Colliery AND Roof Bolting Practices, Dominion Coal Company Limited, Sydney, N. S. AND Discussion - Forum on Roof Bolting AND Roof Bolting Effectivene
A variety of practical tests have been tried in the mining industry to determine the support properties of mine roof bolts. Such tests include torsion wrench readings, hammer blow ...
A Real-Time Approach for Thermal Comfort Management in Electric Vehicles
A Real-Time Approach for Thermal Comfort Management in Electric Vehicles
The HVAC system represents the main auxiliary load in electric vehicles, but passengers’ thermal comfort expectations are always increasing. Hence, a compromise is needed between e...
Occupancy Comfort Evaluation in Green Building Rating Tools in Malaysia: A Comparative Review
Occupancy Comfort Evaluation in Green Building Rating Tools in Malaysia: A Comparative Review
Passive design strategy is the approach that maximizing utilization of natural resources to achieve occupancy comfort which covers the thermal comfort, visual comfort and acoustic ...