Javascript must be enabled to continue!
Why do field seismometers need to be calibrated? Benefits through traceably calibrated seismometers from the laboratory to the field
View through CrossRef
As part of the EU-funded joint research project "Metrology for low-frequency sound and vibration - 19ENV03 Infra-AUV" laboratory calibration methods for seismometers in the low frequency range down to 0.01 Hz have been developed. The reliable knowledge of the full complex sensor response and its associated measurement uncertainty for both, magnitude and phase, improve data quality and reliability by correctly estimating estimating signal amplitude and phase information. Using newly developed on-site calibration approaches, full-frequency responses are estimated for, and the traceability can be transferred to station seismometers of the Comprehensive Nuclear-Test-Ban Treaty Organization’s (CTBTO) International Monitoring System (IMS) during operation without disturbing their regular measurements.With the on-site methodologies in place for co-located sensors, we show how precisely determined full-frequency response information effects seismogram interpretation and the determination of key parameters such as amplitudes and subsequently magnitudes, as well as first motion polarity or event localisation. For that purpose, we use data from on-site calibration tests performed at IMS station PS19 in Germany with both short-period and broadband seismometers calibrated in the laboratories at PTB.Furthermore, the possibility of an array-wide calibration of seismometers with a number of temporary and stationary reference sensors is assessed using suitable excitation signals and station-wide similarity measures. The primary focus is to estimate the required quantity, spacing, and distribution of reference sensors throughout the array.
Title: Why do field seismometers need to be calibrated? Benefits through traceably calibrated seismometers from the laboratory to the field
Description:
As part of the EU-funded joint research project "Metrology for low-frequency sound and vibration - 19ENV03 Infra-AUV" laboratory calibration methods for seismometers in the low frequency range down to 0.
01 Hz have been developed.
The reliable knowledge of the full complex sensor response and its associated measurement uncertainty for both, magnitude and phase, improve data quality and reliability by correctly estimating estimating signal amplitude and phase information.
Using newly developed on-site calibration approaches, full-frequency responses are estimated for, and the traceability can be transferred to station seismometers of the Comprehensive Nuclear-Test-Ban Treaty Organization’s (CTBTO) International Monitoring System (IMS) during operation without disturbing their regular measurements.
With the on-site methodologies in place for co-located sensors, we show how precisely determined full-frequency response information effects seismogram interpretation and the determination of key parameters such as amplitudes and subsequently magnitudes, as well as first motion polarity or event localisation.
For that purpose, we use data from on-site calibration tests performed at IMS station PS19 in Germany with both short-period and broadband seismometers calibrated in the laboratories at PTB.
Furthermore, the possibility of an array-wide calibration of seismometers with a number of temporary and stationary reference sensors is assessed using suitable excitation signals and station-wide similarity measures.
The primary focus is to estimate the required quantity, spacing, and distribution of reference sensors throughout the array.
Related Results
Traceable Calibration of Seismometers
Traceable Calibration of Seismometers
At present, seismometers are not traceably calibrated. This means that their output sensitivity is not determined in a way that is traceable to the International Systems of Units (...
[RETRACTED] Keanu Reeves CBD Gummies v1
[RETRACTED] Keanu Reeves CBD Gummies v1
[RETRACTED]Keanu Reeves CBD Gummies ==❱❱ Huge Discounts:[HURRY UP ] Absolute Keanu Reeves CBD Gummies (Available)Order Online Only!! ❰❰= https://www.facebook.com/Keanu-Reeves-CBD-G...
Characteristics, relationships and precision of direct acoustic-to-seismic coupling measurements from local explosions
Characteristics, relationships and precision of direct acoustic-to-seismic coupling measurements from local explosions
SUMMARY
Acoustic energy originating from explosions, sonic booms, bolides and thunderclaps have been recorded on seismometers since the 1950s. Direct pressure loadin...
Listening to Manchester: Using citizen science Raspberry Shake seismometers to quantify road traffic
Listening to Manchester: Using citizen science Raspberry Shake seismometers to quantify road traffic
Road traffic is a major contributor to greenhouse gases in our cities. This study has been designed to test whether low-cost citizen science seismometers (Raspberry Shakes) can be ...
Mars Reconnaissance Orbiter Context Camera updated in-flight calibration
Mars Reconnaissance Orbiter Context Camera updated in-flight calibration
Introduction: The Context Camera (CTX) has so far delivered more than 145,000 images [1]. The images are one of the most popular datasets for planetary geologists, providing extens...
Regional moment tensor inversion using rotational observations
Regional moment tensor inversion using rotational observations
There are potential benefits from the addition of 3-C rotational motions
to traditional 3-C translational displacements for moment tensor (MT)
inversions. The rotational radiation ...
Brownian Noise and Temperature Sensitivity of Long-Period Lunar Seismometers
Brownian Noise and Temperature Sensitivity of Long-Period Lunar Seismometers
ABSTRACT
As long-period ground motion holds the key to understanding the interior of the Earth’s Moon, reducing long-period noise sources will be an essential area o...
Periodic deep-sea hydrothermal vent activities observed by hydrophones at Mariana, Okinawa, and Mid-Atlantic Ridge
Periodic deep-sea hydrothermal vent activities observed by hydrophones at Mariana, Okinawa, and Mid-Atlantic Ridge
Deep-sea hydrothermal vent activities were studied done by digital OBS/Hs(Ocean Bottom Seismometer / Hydrophone) at three hydrothermal vent areas, the Mariana Trough, the Okinawa T...