Javascript must be enabled to continue!
Electromagnetic Compatibility of Compensating Devices and Converters of an Adjustable Electric Drive in Electrical Networks of Industrial Enterprises
View through CrossRef
The problems of reactive power compensation and improving the quality of electrical energy in the power supply systems of industrial enterprises are inseparable. Their relevance is due to the widespread use of electric receivers that consume reactive power and distort the quality of electrical energy in the network, as well as the implementation of new technologies, systems and equipment into production that make increased demands on the quality of electrical energy consumed. An important characteristic of the quality of electrical energy rationed by GOST 32144–2013 is the non-sinusoidal voltage. The main reason for the non-sinusoidal voltage in the electrical networks of industrial enterprises is the use of electrical equipment with a nonlinear voltage characteristic, which is a source of conductive electromagnetic interference, in particular: adjustable DC and AC electric drives, uninterruptible power supplies of electric receivers, electric welding equipment, electric arc furnaces, induction heating installations, gas-discharge radiation sources. Due to the nonlinearity of the current-voltage characteristics, the above devices consume a non-sinusoidal current from the network, which causes harmonic distortion of the supply voltage, including the fundamental harmonic component and higher harmonic components that are multiples of the fundamental frequency. Non-sinusoidal voltage, in turn, causes additional losses of power and energy in the elements of the electrical network, causes overheating and accelerated aging of the insulation of electrical equipment, reducing its operational reliability and reducing service life, worsens the accuracy of electrical measurements, causes malfunctions in automation systems, telemechanics, relay protection, electronic systems and communications. Non-sinusoidal voltage significantly complicates the compensation of reactive power in the electrical network. Compensating devices are made on the basis of capacitors, whose electrical parameters (resistance, power, current) depend on both the magnitude of the supply voltage and its harmonic composition. The present article identifies problems and proposes solutions in terms of reactive power compensation and improving the quality of electrical energy in electrical networks containing thyristor voltage converters and frequency converters used in adjustable electric drive installations of industrial enterprises.
Belarusian National Technical University
Title: Electromagnetic Compatibility of Compensating Devices and Converters of an Adjustable Electric Drive in Electrical Networks of Industrial Enterprises
Description:
The problems of reactive power compensation and improving the quality of electrical energy in the power supply systems of industrial enterprises are inseparable.
Their relevance is due to the widespread use of electric receivers that consume reactive power and distort the quality of electrical energy in the network, as well as the implementation of new technologies, systems and equipment into production that make increased demands on the quality of electrical energy consumed.
An important characteristic of the quality of electrical energy rationed by GOST 32144–2013 is the non-sinusoidal voltage.
The main reason for the non-sinusoidal voltage in the electrical networks of industrial enterprises is the use of electrical equipment with a nonlinear voltage characteristic, which is a source of conductive electromagnetic interference, in particular: adjustable DC and AC electric drives, uninterruptible power supplies of electric receivers, electric welding equipment, electric arc furnaces, induction heating installations, gas-discharge radiation sources.
Due to the nonlinearity of the current-voltage characteristics, the above devices consume a non-sinusoidal current from the network, which causes harmonic distortion of the supply voltage, including the fundamental harmonic component and higher harmonic components that are multiples of the fundamental frequency.
Non-sinusoidal voltage, in turn, causes additional losses of power and energy in the elements of the electrical network, causes overheating and accelerated aging of the insulation of electrical equipment, reducing its operational reliability and reducing service life, worsens the accuracy of electrical measurements, causes malfunctions in automation systems, telemechanics, relay protection, electronic systems and communications.
Non-sinusoidal voltage significantly complicates the compensation of reactive power in the electrical network.
Compensating devices are made on the basis of capacitors, whose electrical parameters (resistance, power, current) depend on both the magnitude of the supply voltage and its harmonic composition.
The present article identifies problems and proposes solutions in terms of reactive power compensation and improving the quality of electrical energy in electrical networks containing thyristor voltage converters and frequency converters used in adjustable electric drive installations of industrial enterprises.
.
Related Results
EPD Electronic Pathogen Detection v1
EPD Electronic Pathogen Detection v1
Electronic pathogen detection (EPD) is a non - invasive, rapid, affordable, point- of- care test, for Covid 19 resulting from infection with SARS-CoV-2 virus. EPD scanning techno...
Wide Bandgap Converters for High-Frequency Renewable Energies
Wide Bandgap Converters for High-Frequency Renewable Energies
Wide bandgap (WBG) converters utilise semiconductor materials such as gallium nitride (GaN) and silicon carbide (SiC), in contrast to conventional silicon (Si) devices, hence enhan...
Wide Bandgap Converters for High-Frequency Renewable Energies
Wide Bandgap Converters for High-Frequency Renewable Energies
Wide bandgap (WBG) converters utilise semiconductor materials such as gallium nitride (GaN) and silicon carbide (SiC), in contrast to conventional silicon (Si) devices, hence enhan...
A Review on Coupled Inductor-Based High Step-Up DC-DC Converters for Renewable Energy Sources
A Review on Coupled Inductor-Based High Step-Up DC-DC Converters for Renewable Energy Sources
Renewable energy sources are increasingly being embraced due to their environmental advantages, characterized by clean energy production, including solar energy, fuel cells, and wi...
Electric drive with frequency-regulated synchronous motor with high precision digital sensors
Electric drive with frequency-regulated synchronous motor with high precision digital sensors
The article studies an electric drive with a frequency-regulated synchronous motor.The main advantages of synchronous motors in comparison with asynchronous ones are listed.The cur...
Study on the characteristics and synergistic effects of industrial complex networks – empirical evidence from Chinese manufacturing
Study on the characteristics and synergistic effects of industrial complex networks – empirical evidence from Chinese manufacturing
PurposeThe manufacturing industry and the producer service industry have a high degree of industrial correlation, and their integration will cause changes in the complex industrial...
Electromagnetic radiation of hybrid vehicles
Electromagnetic radiation of hybrid vehicles
Problem. As a result of automobile traffic every year 20-30% of the territory of cities are subject to electromagnetic pollution in cities and settlements. This is due to the incre...
The level of electrical resistance on electrolyte materials
The level of electrical resistance on electrolyte materials
Electricity causes a variety of well-known effects, such as lightning, static electricity, electromagnetic induction, and electric current. The presence of electricity can also gen...

