Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Visual satisfaction with progressive addition lenses prescribed with novel foveal fixation axis measurements

View through CrossRef
AbstractProgressive addition lens (PAL) prescription is usually conducted using the pupillary centre as a reference, which in general does not coincide with the visual axis (kappa distance), and this difference could induce undesired prismatic effects in far and near vision distances and adaptation problems. This study aimed to assess the impact on subjects’ visual satisfaction with PALs prescribed based on foveal fixation axis (FFA) measurements. Two different PALs (LifeStyle 3i, Hoya Lens Iberia) were randomly prescribed [one with a customized inset (the difference between the FFA measurements (Ergofocus®, Lentitech, Spain) at far and near distances and the second with a standard inset (2.5 mm)] to be used by 71 healthy presbyopic volunteers in a prospective double-masked crossover clinical study involving one month of use of each PAL. Patients were self-classified into four groups according to their previous experience with PALs: neophyte, PAL users, PAL drop-out, and uncomfortable PAL users. Visual function and overall satisfaction with each PAL were collected and compared. Ninety-seven percent (95% CI 93–100%) of participants successfully adapted to PALs prescribed with FFA without significant differences (P = 0.26) among the study groups (100% neophyte and uncomfortable PAL users (95% CI 100% in both groups), 89% (95% CI 67–100%) PAL users and 94% (95% CI 82–100%) PAL drop-out group). There were no statistically significant differences in visual function (P > 0.05) between customized and standard inset PALs. Customized and standard inset lenses showed similar satisfaction (P > 0.42) that increased significantly (P < 0.01 without any carry-over effect) after 30 days of wear. PALs prescribed with FFA measurements showed high visual satisfaction, suggesting that these measurements are suitable for prescribing PAL adaptation processes. Additional research is necessary to assess differences in PAL users’ performance with different prescription methods and lens designs.
Title: Visual satisfaction with progressive addition lenses prescribed with novel foveal fixation axis measurements
Description:
AbstractProgressive addition lens (PAL) prescription is usually conducted using the pupillary centre as a reference, which in general does not coincide with the visual axis (kappa distance), and this difference could induce undesired prismatic effects in far and near vision distances and adaptation problems.
This study aimed to assess the impact on subjects’ visual satisfaction with PALs prescribed based on foveal fixation axis (FFA) measurements.
Two different PALs (LifeStyle 3i, Hoya Lens Iberia) were randomly prescribed [one with a customized inset (the difference between the FFA measurements (Ergofocus®, Lentitech, Spain) at far and near distances and the second with a standard inset (2.
5 mm)] to be used by 71 healthy presbyopic volunteers in a prospective double-masked crossover clinical study involving one month of use of each PAL.
Patients were self-classified into four groups according to their previous experience with PALs: neophyte, PAL users, PAL drop-out, and uncomfortable PAL users.
Visual function and overall satisfaction with each PAL were collected and compared.
Ninety-seven percent (95% CI 93–100%) of participants successfully adapted to PALs prescribed with FFA without significant differences (P = 0.
26) among the study groups (100% neophyte and uncomfortable PAL users (95% CI 100% in both groups), 89% (95% CI 67–100%) PAL users and 94% (95% CI 82–100%) PAL drop-out group).
There were no statistically significant differences in visual function (P > 0.
05) between customized and standard inset PALs.
Customized and standard inset lenses showed similar satisfaction (P > 0.
42) that increased significantly (P < 0.
01 without any carry-over effect) after 30 days of wear.
PALs prescribed with FFA measurements showed high visual satisfaction, suggesting that these measurements are suitable for prescribing PAL adaptation processes.
Additional research is necessary to assess differences in PAL users’ performance with different prescription methods and lens designs.

Related Results

FOVEAL DISPLACEMENT IN EYES WITH EPIRETINAL MEMBRANE AFTER VITRECTOMY AND MEMBRANE PEELING
FOVEAL DISPLACEMENT IN EYES WITH EPIRETINAL MEMBRANE AFTER VITRECTOMY AND MEMBRANE PEELING
Purpose: To investigate the foveal movement in eyes with epiretinal membrane after vitrectomy and membrane peeling. Methods: ...
Distinct visual processing networks for foveal and peripheral visual fields
Distinct visual processing networks for foveal and peripheral visual fields
AbstractFoveal and peripheral vision are two distinct modes of visual processing essential for navigating the world. However, it remains unclear if they engage different neural mec...
Técnicas de reconstrucción y compensación activa de frentes de onda complejos
Técnicas de reconstrucción y compensación activa de frentes de onda complejos
The continuous improvements of optical design tools and manufacturing technologies of free-form optical elements, allow the creation of new complex-shaped lenses that improve the p...
Clinical comparison of two specialty soft lenses for Keratoconus
Clinical comparison of two specialty soft lenses for Keratoconus
(English) Due to advanced diagnostic instruments for detection of early-stage keratoconus (KC), and procedures that halt its progression such as corneal collagen cross-linking (CXL...
Comparing 3 Different Techniques of Patella Fracture Fixation and Their Complications
Comparing 3 Different Techniques of Patella Fracture Fixation and Their Complications
Introduction: Patella fractures managed by fixation with metal implants often cause local soft tissue irritation and necessitate implant removal. An alternative is to utilize sutur...
Microsaccade generation requires a foveal anchor
Microsaccade generation requires a foveal anchor
Visual scene characteristics have the ability to affect various aspects of saccade and microsaccade dynamics. For example, blank visual scenes are known to elicit diminished saccad...

Back to Top