Anisotropy of dose contributions—An instrument to upgrade real time IMRT and VMAT adaptation?
View through CrossRef
PurposeTo suggest a definition of dose deposition anisotropy for the purpose of ad hoc adaptation of intensity modulated arc therapy (IMRT) and volumetric arc therapy (VMAT), particularly in the vicinity of important organs at risk (OAR), also for large deformations.MethodsBeam's‐eye‐view (BEV) based fluence warping is a standard adaptation method with disadvantages for strongly varying OAR shapes. 2‐Step‐adaptation overcomes these difficulties by a deeper analysis of the 3D properties of adaptation processes, but requires separate arcs for every OAR to spare, which makes it impractical for cases with multiple OARs. The authors aim to extend the 2‐Step method to arbitrary intensity modulated plan by analyzing the anisotropy of dose contributions. Anisotropy was defined as a second term of Fourier transformation of gantry angle dependent dose contributions. For a cylindrical planning target volume (PTV) surrounding an OAR of varying diameter, the anisotropy and the dose‐normalized anisotropy were analyzed for several scenarios of optimized fluence distributions. 2‐Step adaptation to decreasing and increasing OAR diameter was performed, and compared to a usual fluence based adaptation method. For two clinical cases, prostate and neck, the VMAT was generated and the behavior of anisotropy was qualitatively explored for deformed organs at risk.ResultsDose contribution anisotropy in the PTV peaks around nearby OARs. The thickness of the “anisotropy wall” around OAR increases for increasing OAR radius, as also does the width of 2‐Step dose saturating fluence peak adjacent to the OAR [K. Bratengeier et al., “A comparison between 2‐Step IMRT and conventional IMRT planning,” Radiother. Oncol. 84, 298–306 (2007)]. Different optimized beam fluence profiles resulted in comparable radial dependence of normalized anisotropy. As predicted, even for patient cases, anisotropy was inflated even more than increasing diameters of OAR.ConclusionsFor cylindrically symmetric cases, the dose distribution anisotropy defined in the present work implicitly contains adaptation‐relevant information about 3D relationships between PTV and OAR and degree of OAR sparing. For more complex realistic cases, it shows the predicted behavior qualitatively. The authors claim to have found a first component for advancing a 2‐Step adaptation to a universal adaptation algorithm based on the BEV projection of the dose anisotropy. Further planning studies to explore the potential of anisotropy for adaptation algorithms using phantoms and clinical cases of differing complexity will follow.
Title: Anisotropy of dose contributions—An instrument to upgrade real time IMRT and VMAT adaptation?
Description:
PurposeTo suggest a definition of dose deposition anisotropy for the purpose of ad hoc adaptation of intensity modulated arc therapy (IMRT) and volumetric arc therapy (VMAT), particularly in the vicinity of important organs at risk (OAR), also for large deformations.
MethodsBeam's‐eye‐view (BEV) based fluence warping is a standard adaptation method with disadvantages for strongly varying OAR shapes.
2‐Step‐adaptation overcomes these difficulties by a deeper analysis of the 3D properties of adaptation processes, but requires separate arcs for every OAR to spare, which makes it impractical for cases with multiple OARs.
The authors aim to extend the 2‐Step method to arbitrary intensity modulated plan by analyzing the anisotropy of dose contributions.
Anisotropy was defined as a second term of Fourier transformation of gantry angle dependent dose contributions.
For a cylindrical planning target volume (PTV) surrounding an OAR of varying diameter, the anisotropy and the dose‐normalized anisotropy were analyzed for several scenarios of optimized fluence distributions.
2‐Step adaptation to decreasing and increasing OAR diameter was performed, and compared to a usual fluence based adaptation method.
For two clinical cases, prostate and neck, the VMAT was generated and the behavior of anisotropy was qualitatively explored for deformed organs at risk.
ResultsDose contribution anisotropy in the PTV peaks around nearby OARs.
The thickness of the “anisotropy wall” around OAR increases for increasing OAR radius, as also does the width of 2‐Step dose saturating fluence peak adjacent to the OAR [K.
Bratengeier et al.
, “A comparison between 2‐Step IMRT and conventional IMRT planning,” Radiother.
Oncol.
84, 298–306 (2007)].
Different optimized beam fluence profiles resulted in comparable radial dependence of normalized anisotropy.
As predicted, even for patient cases, anisotropy was inflated even more than increasing diameters of OAR.
ConclusionsFor cylindrically symmetric cases, the dose distribution anisotropy defined in the present work implicitly contains adaptation‐relevant information about 3D relationships between PTV and OAR and degree of OAR sparing.
For more complex realistic cases, it shows the predicted behavior qualitatively.
The authors claim to have found a first component for advancing a 2‐Step adaptation to a universal adaptation algorithm based on the BEV projection of the dose anisotropy.
Further planning studies to explore the potential of anisotropy for adaptation algorithms using phantoms and clinical cases of differing complexity will follow.
Related Results
Modified VMAT Plans for Locally Advanced Centrally Located Non-Small Cell Lung Cancer (NSCLC)
Modified VMAT Plans for Locally Advanced Centrally Located Non-Small Cell Lung Cancer (NSCLC)
Objectives: This study aimed to find the optimal radiotherapy VMAT plans, that achieved high conformity and homogeneity to the planned target volume (PTV), and minimize the dose to...
Dosimetric comparative study of Volumetric Modulated Arc Therapy (VMAT), Intensity Modulated Radiotherapy (IMRT), and ThreeDimensional Conformal Radiation therapy (3DCRT) for post-mastectomy radiotherapy (PMRT) in Left breast cancer patients
Dosimetric comparative study of Volumetric Modulated Arc Therapy (VMAT), Intensity Modulated Radiotherapy (IMRT), and ThreeDimensional Conformal Radiation therapy (3DCRT) for post-mastectomy radiotherapy (PMRT) in Left breast cancer patients
Purpose: To evaluate the difference in planning target volume (PTV) coverage and dose to the organs at risk
(OAR) by using three different planning methods for the same patient-Vol...
Strategies for reducing ovarian dose in volumetric modulated arc therapy (VMAT) for postoperative uterine cervical cancer
Strategies for reducing ovarian dose in volumetric modulated arc therapy (VMAT) for postoperative uterine cervical cancer
Objective:
To reduce the ovarian dose with volumetric modulated arc therapy (VMAT), an original VMAT was designed with two types of arcs to restrict angles and fi...
Dose and normal tissue complication probability analysis of various radiotherapy regimens for thymomas
Dose and normal tissue complication probability analysis of various radiotherapy regimens for thymomas
Objective
This study aimed to compare dosimetric differences and normal tissue complication probability (NTCP) among coplanar intensity-modulated radiation ther...
SU‐C‐211‐04: Evaluation of IMRT and VMAT Treatment Plan Quality Delivered with and Without Flattening Filter Using Pareto Optimal Fronts
SU‐C‐211‐04: Evaluation of IMRT and VMAT Treatment Plan Quality Delivered with and Without Flattening Filter Using Pareto Optimal Fronts
Purpose: To evaluate treatment plan quality of IMRT and VMAT plans for high energy photon beams delivered with (FF) and without (FFF) flattening filter. Methods: 9‐field IMRT and 3...
COMPARISON OF COPLANAR AND NON- COPLANARVMAT FOR BRAIN CANCER BY USING THE DOSIMETRICAL AND RADIOBIOLOGICAL INDICES
COMPARISON OF COPLANAR AND NON- COPLANARVMAT FOR BRAIN CANCER BY USING THE DOSIMETRICAL AND RADIOBIOLOGICAL INDICES
Background: Recent techniques of radiotherapy such as volumetric modulated arc therapy (VMAT) that delivered in Coplanar technique or non-coplanar technique allows to deliver high ...
So sánh kỹ thuật xạ trị 3D-CRT, IMRT và VMAT trong điều trị ung thư phổi sử dụng xạ trị lập thể định vị thân
So sánh kỹ thuật xạ trị 3D-CRT, IMRT và VMAT trong điều trị ung thư phổi sử dụng xạ trị lập thể định vị thân
Purpose: To compare the difference of dose distribution and physical characteristics on treatment plans using Three-Dimensional Conformal Radiation Therapy (3D-CRT), Intensity Modu...
Dosimetric comparison of 3DCRT and IMRT in radical chemoradiotherapy of squamous cell carcinoma esophagus
Dosimetric comparison of 3DCRT and IMRT in radical chemoradiotherapy of squamous cell carcinoma esophagus
ABSTRACT
Background:
Radical chemoradiation is the standard of treatment for locally advanced squamous cell carcinoma of esophagus and for patien...