Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

PICOSEC-Micromegas: Robustness measurements and study of different photocathode materials

View through CrossRef
Abstract Detectors with a time resolution of 20-30 ps and a reliable performance in high particles flux environments are necessary for an accurate vertex separation in future HEP experiments. The PICOSEC-Micromegas detector concept is a Micro-Pattern Gaseous Detector (MPGD) based solution addressing this particular challenge. The PICOSEC-Micromegas concept is based on a Micromegas detector coupled to a Cherenkov radiator and a photocathode. In this detector concept, all primary electrons are initiated in the photocathode and the time jitter fluctuations are reduced. Different resistive anode layers have been tested with the goal of preserving a stable detector operation in a high intensity pion beam. One important characteristic of a gaseous detector in a high flux environment is the ion backflow (IBF). That can cause damage to more fragile photocathode materials like CsI. Various types of photocathode materials have been tested in order to find a robust solution against IBF bombardment.
Title: PICOSEC-Micromegas: Robustness measurements and study of different photocathode materials
Description:
Abstract Detectors with a time resolution of 20-30 ps and a reliable performance in high particles flux environments are necessary for an accurate vertex separation in future HEP experiments.
The PICOSEC-Micromegas detector concept is a Micro-Pattern Gaseous Detector (MPGD) based solution addressing this particular challenge.
The PICOSEC-Micromegas concept is based on a Micromegas detector coupled to a Cherenkov radiator and a photocathode.
In this detector concept, all primary electrons are initiated in the photocathode and the time jitter fluctuations are reduced.
Different resistive anode layers have been tested with the goal of preserving a stable detector operation in a high intensity pion beam.
One important characteristic of a gaseous detector in a high flux environment is the ion backflow (IBF).
That can cause damage to more fragile photocathode materials like CsI.
Various types of photocathode materials have been tested in order to find a robust solution against IBF bombardment.

Related Results

Design and performance of a 96-channel resistive PICOSEC Micromegas detector for ENUBET
Design and performance of a 96-channel resistive PICOSEC Micromegas detector for ENUBET
Abstract The PICOSEC-Micromegas (PICOSEC-MM) detector is a fast gaseous detector concept that achieves picosecond-level timing. It couple...
A novel diamond-like carbon based photocathode for PICOSEC Micromegas detectors
A novel diamond-like carbon based photocathode for PICOSEC Micromegas detectors
Abstract The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector based on a MM detector operating in a two-stage amplification mode and a Chere...
Towards robust PICOSEC Micromegas precise timing detectors
Towards robust PICOSEC Micromegas precise timing detectors
Abstract The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector consisting of a Cherenkov radiator combined with a photocathode and a MM amplify...
Recent Developments on Precise Timing with the PICOSEC Micromegas Detector
Recent Developments on Precise Timing with the PICOSEC Micromegas Detector
Abstract The PICOSEC-Micromegas detector was developed for precise timing of the arrival of charged particles with a resolution bellow 30 ps. This contribution, afte...
Spatial resolution improvement of PICOSEC Micromegas precise timing detectors
Spatial resolution improvement of PICOSEC Micromegas precise timing detectors
Abstract The combination of a Cherenkov radiator with a semi transparent photocathode and a Micromegas based amplification stage allows P...
Precise timing and recent advancements with segmented anode PICOSEC Micromegas prototypes
Precise timing and recent advancements with segmented anode PICOSEC Micromegas prototypes
Abstract Timing information in current and future accelerator facilities is important for resolving objects (particle tracks, showers, etc.) in extreme large particl...
PICOSEC Micromegas precise-timing detectors: development towards large-area application and integration
PICOSEC Micromegas precise-timing detectors: development towards large-area application and integration
Abstract PICOSEC Micromegas (MM) is a precise timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and an MM amplifying...
A large area 100-channel PICOSEC Micromegas detector with time resolution at the 20 ps level
A large area 100-channel PICOSEC Micromegas detector with time resolution at the 20 ps level
AbstractThe PICOSEC Micromegas precise timing detector is based on a Cherenkov radiator coupled to a photocathode operating in a semi-transparent mode and a Micromegas amplificatio...

Back to Top