Javascript must be enabled to continue!
Towards robust PICOSEC Micromegas precise timing detectors
View through CrossRef
Abstract
The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector consisting of
a Cherenkov radiator combined with a photocathode and a MM amplifying structure. A 100-channel
PICOSEC MM prototype with 10 × 10 cm2 active area equipped with a Cesium Iodide (CsI)
photocathode demonstrated a time resolution below σ = 18 ps. The objective of this work
is to improve the PICOSEC MM detector robustness aspects, i.e. integration of resistive MM and
carbon-based photocathodes, while maintaining good time resolution. The PICOSEC MM prototypes
have been tested in laboratory conditions and successfully characterised with 150 GeV/c muon
beams at the CERN SPS H4 beam line. The excellent timing performance below σ = 20 ps for
an individual pad obtained with the 10 × 10 cm2 area resistive PICOSEC MM of
20 MΩ/□ showed no significant time resolution degradation as a result of adding a
resistive layer. A single-pad prototype equipped with a 12 nm thick Boron Carbide (B4C)
photocathode presented a time resolution below σ = 35 ps, opening up new possibilities for
detectors with robust photocathodes. The results made the concept more suitable for the
experiments in need of robust detectors with good time resolution.
IOP Publishing
M. Lisowska
Y. Angelis
S. Aune
J. Bortfeldt
F. Brunbauer
E. Chatzianagnostou
K. Dehmelt
D. Desforge
G. Fanourakis
K.J. Floethner
M. Gallinaro
F. Garcia
P. Garg
I. Giomataris
K. Gnanvo
T. Gustavsson
F.J. Iguaz
D. Janssens
A. Kallitsopoulou
M. Kovacic
P. Legou
J. Liu
M. Lupberger
S. Malace
I. Maniatis
Y. Meng
H. Muller
E. Oliveri
G. Orlandini
T. Papaevangelou
M. Pomorski
L. Ropelewski
D. Sampsonidis
L. Scharenberg
T. Schneider
E. Scorsone
L. Sohl
M. van Stenis
Y. Tsipolitis
S.E. Tzamarias
A. Utrobicic
R. Veenhof
X. Wang
S. White
Z. Zhang
Y. Zhou
Title: Towards robust PICOSEC Micromegas precise timing detectors
Description:
Abstract
The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector consisting of
a Cherenkov radiator combined with a photocathode and a MM amplifying structure.
A 100-channel
PICOSEC MM prototype with 10 × 10 cm2 active area equipped with a Cesium Iodide (CsI)
photocathode demonstrated a time resolution below σ = 18 ps.
The objective of this work
is to improve the PICOSEC MM detector robustness aspects, i.
e.
integration of resistive MM and
carbon-based photocathodes, while maintaining good time resolution.
The PICOSEC MM prototypes
have been tested in laboratory conditions and successfully characterised with 150 GeV/c muon
beams at the CERN SPS H4 beam line.
The excellent timing performance below σ = 20 ps for
an individual pad obtained with the 10 × 10 cm2 area resistive PICOSEC MM of
20 MΩ/□ showed no significant time resolution degradation as a result of adding a
resistive layer.
A single-pad prototype equipped with a 12 nm thick Boron Carbide (B4C)
photocathode presented a time resolution below σ = 35 ps, opening up new possibilities for
detectors with robust photocathodes.
The results made the concept more suitable for the
experiments in need of robust detectors with good time resolution.
Related Results
Design and performance of a 96-channel resistive PICOSEC Micromegas detector for ENUBET
Design and performance of a 96-channel resistive PICOSEC Micromegas detector for ENUBET
Abstract
The PICOSEC-Micromegas (PICOSEC-MM) detector is a fast
gaseous detector concept that achieves picosecond-level timing. It
couple...
Precise timing and recent advancements with segmented anode PICOSEC Micromegas prototypes
Precise timing and recent advancements with segmented anode PICOSEC Micromegas prototypes
Abstract
Timing information in current and future accelerator facilities is important for resolving objects (particle tracks, showers, etc.) in extreme large particl...
Spatial resolution improvement of PICOSEC Micromegas precise timing detectors
Spatial resolution improvement of PICOSEC Micromegas precise timing detectors
Abstract
The combination of a Cherenkov radiator with a semi
transparent photocathode and a Micromegas based amplification stage
allows P...
Recent Developments on Precise Timing with the PICOSEC Micromegas Detector
Recent Developments on Precise Timing with the PICOSEC Micromegas Detector
Abstract
The PICOSEC-Micromegas detector was developed for precise timing of the arrival of charged particles with a resolution bellow 30 ps. This contribution, afte...
PICOSEC Micromegas precise-timing detectors: development towards large-area application and integration
PICOSEC Micromegas precise-timing detectors: development towards large-area application and integration
Abstract
PICOSEC Micromegas (MM) is a precise timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and an MM amplifying...
A novel diamond-like carbon based photocathode for PICOSEC Micromegas detectors
A novel diamond-like carbon based photocathode for PICOSEC Micromegas detectors
Abstract
The PICOSEC Micromegas (MM) detector is a precise timing
gaseous detector based on a MM detector operating in a two-stage
amplification mode and a Chere...
A large area 100-channel PICOSEC Micromegas detector with time resolution at the 20 ps level
A large area 100-channel PICOSEC Micromegas detector with time resolution at the 20 ps level
AbstractThe PICOSEC Micromegas precise timing detector is based on a Cherenkov radiator coupled to a photocathode operating in a semi-transparent mode and a Micromegas amplificatio...
PICOSEC-Micromegas: Robustness measurements and study of different photocathode materials
PICOSEC-Micromegas: Robustness measurements and study of different photocathode materials
Abstract
Detectors with a time resolution of 20-30 ps and a reliable performance in high particles flux environments are necessary for an accurate vertex separation ...

