Javascript must be enabled to continue!
A large area 100-channel PICOSEC Micromegas detector with time resolution at the 20 ps level
View through CrossRef
AbstractThe PICOSEC Micromegas precise timing detector is based on a Cherenkov radiator coupled to a photocathode operating in a semi-transparent mode and a Micromegas amplification structure. The first proof of concept single-channel prototype was able to achieve a time resolution below 25 ps. One of the crucial aspects in the development of precise timing gaseous detectors applicable in high-energy physics experiments is a modular design that enables large area coverage. The first 19-channel multi-pad prototype with an active area of approximately 10 cm2suffered from degraded timing resolution due to the non-uniformity of the preamplification gap thickness. A new 100 cm2detector module with 100 channels based on a rigid hybrid ceramic/FR4 Micromegas board for improved drift gap uniformity was developed. Initial measurements with 80 GeV/c muons showed improvements in timing response over the measured pads and a time resolution below 25 ps. More recent measurements with a thinner drift gap detector module and newly developed RF pulse amplifiers show that the pad centre resolution can be enhanced to the level of 17 ps. This work will present the development of the detector from structural simulations, design, and beam test commissioning with a focus on the timing performance of a thinner drift gap detector module in combination with new electronics using an automated timing scan method.
IOP Publishing
A. Utrobicic
Y. Angelis
J. Bortfeldt
F. Brunbauer
E. Chatzianagnostou
K. Dehmelt
G. Fanourakis
K.J. Floethner
M. Gallinaro
F. Garcia
P. Garg
I. Giomataris
K. Gnanvo
T. Gustavsson
F.J. Iguaz
D. Janssens
A. Kallitsopoulou
M. Kovacic
P. Legou
M. Lisowska
J. Liu
M. Lupberger
I. Maniatis
Y. Meng
H. Muller
E. Oliveri
G. Orlandini
T. Papaevangelou
M. Pomorski
L. Ropelewski
D. Sampsonidis
L. Scharenberg
T. Schneider
L. Sohl
M. van Stenis
Y. Tsipolitis
S.E. Tzamarias
R. Veenhof
X. Wang
S. White
Z. Zhang
Y. Zhou
Title: A large area 100-channel PICOSEC Micromegas detector with time resolution at the 20 ps level
Description:
AbstractThe PICOSEC Micromegas precise timing detector is based on a Cherenkov radiator coupled to a photocathode operating in a semi-transparent mode and a Micromegas amplification structure.
The first proof of concept single-channel prototype was able to achieve a time resolution below 25 ps.
One of the crucial aspects in the development of precise timing gaseous detectors applicable in high-energy physics experiments is a modular design that enables large area coverage.
The first 19-channel multi-pad prototype with an active area of approximately 10 cm2suffered from degraded timing resolution due to the non-uniformity of the preamplification gap thickness.
A new 100 cm2detector module with 100 channels based on a rigid hybrid ceramic/FR4 Micromegas board for improved drift gap uniformity was developed.
Initial measurements with 80 GeV/c muons showed improvements in timing response over the measured pads and a time resolution below 25 ps.
More recent measurements with a thinner drift gap detector module and newly developed RF pulse amplifiers show that the pad centre resolution can be enhanced to the level of 17 ps.
This work will present the development of the detector from structural simulations, design, and beam test commissioning with a focus on the timing performance of a thinner drift gap detector module in combination with new electronics using an automated timing scan method.
Related Results
Design and performance of a 96-channel resistive PICOSEC Micromegas detector for ENUBET
Design and performance of a 96-channel resistive PICOSEC Micromegas detector for ENUBET
Abstract
The PICOSEC-Micromegas (PICOSEC-MM) detector is a fast
gaseous detector concept that achieves picosecond-level timing. It
couple...
Evolution of Antimicrobial Resistance in Community vs. Hospital-Acquired Infections
Evolution of Antimicrobial Resistance in Community vs. Hospital-Acquired Infections
Abstract
Introduction
Hospitals are high-risk environments for infections. Despite the global recognition of these pathogens, few studies compare microorganisms from community-acqu...
Precise timing and recent advancements with segmented anode PICOSEC Micromegas prototypes
Precise timing and recent advancements with segmented anode PICOSEC Micromegas prototypes
Abstract
Timing information in current and future accelerator facilities is important for resolving objects (particle tracks, showers, etc.) in extreme large particl...
Towards robust PICOSEC Micromegas precise timing detectors
Towards robust PICOSEC Micromegas precise timing detectors
Abstract
The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector consisting of
a Cherenkov radiator combined with a photocathode and a MM amplify...
Recent Developments on Precise Timing with the PICOSEC Micromegas Detector
Recent Developments on Precise Timing with the PICOSEC Micromegas Detector
Abstract
The PICOSEC-Micromegas detector was developed for precise timing of the arrival of charged particles with a resolution bellow 30 ps. This contribution, afte...
Spatial resolution improvement of PICOSEC Micromegas precise timing detectors
Spatial resolution improvement of PICOSEC Micromegas precise timing detectors
Abstract
The combination of a Cherenkov radiator with a semi
transparent photocathode and a Micromegas based amplification stage
allows P...
PICOSEC Micromegas precise-timing detectors: development towards large-area application and integration
PICOSEC Micromegas precise-timing detectors: development towards large-area application and integration
Abstract
PICOSEC Micromegas (MM) is a precise timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and an MM amplifying...
PICOSEC-Micromegas: Robustness measurements and study of different photocathode materials
PICOSEC-Micromegas: Robustness measurements and study of different photocathode materials
Abstract
Detectors with a time resolution of 20-30 ps and a reliable performance in high particles flux environments are necessary for an accurate vertex separation ...

