Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Comparison of Accuracy and Time for Four Implant Placement Techniques Supporting Fixed-Partial Denture

View through CrossRef
Various guiding methods are used to place implants. This ex vivo pilot study used a convenience sample to examine time and accuracy for placement of 2 dental implants supporting a 3-unit fixed prosthesis on a simulation model using freehand and 3 guided placement techniques. Four operators with no prior implant placement experiences were randomly assigned placement of 2 maxillary or mandibular implants for a fixed prosthesis. Techniques included dynamic navigation (DN), static guide (SG), template-based guide (TBG), and freehand placement (FH). Preoperative and operative times were recorded. Discrepancies between the planned and placed implant positions were assessed by superimposing preoperative and postoperative cone beam computerized tomography scans. Data were analyzed with repeated-measures regression with Tukey's adjusted pairwise comparisons (α = 0.05). Dynamic navigation was associated with the longest operative time (13.5 minutes vs 5–10.2, P = .0001) but overall fastest when incorporating preoperative time (32.1 minutes vs 143–181.5, P < .0001). All deviation measures were significantly associated with the placement method (P < .05) except apex vertical deviation (P = .3925). Implants placed by SG had significantly lower entry 2-dimensional deviation than the other methods, particularly on the mandible. The DN and SG methods had significantly lower Apex 3D and overall angle deviations, again particularly on the mandible. The mandible had significantly higher deviations than maxilla. Within limitations of this study, implant placement by novice operators is more accurate when using dynamic and static guidance compared to freehand and template-based techniques.
Title: Comparison of Accuracy and Time for Four Implant Placement Techniques Supporting Fixed-Partial Denture
Description:
Various guiding methods are used to place implants.
This ex vivo pilot study used a convenience sample to examine time and accuracy for placement of 2 dental implants supporting a 3-unit fixed prosthesis on a simulation model using freehand and 3 guided placement techniques.
Four operators with no prior implant placement experiences were randomly assigned placement of 2 maxillary or mandibular implants for a fixed prosthesis.
Techniques included dynamic navigation (DN), static guide (SG), template-based guide (TBG), and freehand placement (FH).
Preoperative and operative times were recorded.
Discrepancies between the planned and placed implant positions were assessed by superimposing preoperative and postoperative cone beam computerized tomography scans.
Data were analyzed with repeated-measures regression with Tukey's adjusted pairwise comparisons (α = 0.
05).
Dynamic navigation was associated with the longest operative time (13.
5 minutes vs 5–10.
2, P = .
0001) but overall fastest when incorporating preoperative time (32.
1 minutes vs 143–181.
5, P < .
0001).
All deviation measures were significantly associated with the placement method (P < .
05) except apex vertical deviation (P = .
3925).
Implants placed by SG had significantly lower entry 2-dimensional deviation than the other methods, particularly on the mandible.
The DN and SG methods had significantly lower Apex 3D and overall angle deviations, again particularly on the mandible.
The mandible had significantly higher deviations than maxilla.
Within limitations of this study, implant placement by novice operators is more accurate when using dynamic and static guidance compared to freehand and template-based techniques.

Related Results

Tensile Bond Strength between Different Denture Base Materials and Soft Denture Liners
Tensile Bond Strength between Different Denture Base Materials and Soft Denture Liners
(1) Background: Various materials are available for CAD-CAM denture base fabrication, for both additive and subtractive manufacturing. However, little has been reported on bond str...
Contemporary methods and mobile denture cleansers and theirs significance for older population
Contemporary methods and mobile denture cleansers and theirs significance for older population
Introduction. A dramatic increase in the number of people living in their seventies, eighties and nineties is associated with a loss of teeth and the use of mobile dentures. ...
Evaluation of Oral Stereognosis in Relation to Tactile Ability and Patient Satisfaction
Evaluation of Oral Stereognosis in Relation to Tactile Ability and Patient Satisfaction
We investigated the oral stereognostic ability (OSA) of dentate individuals, conventional complete denture patients, and maxillary implant-supported denture patients with bar attac...
Antifungal effects of eugenol on Candida albicans adherence to denture polymers
Antifungal effects of eugenol on Candida albicans adherence to denture polymers
Background The study’s objective is to assess the adherence of C. albicans in different types of denture polymers and the effectiveness of eugenol and commercialized...
Microflora in denture stomatitis - A review
Microflora in denture stomatitis - A review
Denture stomatitis is an inflammation that typically occurs in individuals that have a complete or partial denture. Denture stomatitis is commonly defined as persistent inflammator...
Fit Accuracy of Complete Denture Base Fabricated by CAD/CAM Milling and 3D-Printing Methods
Fit Accuracy of Complete Denture Base Fabricated by CAD/CAM Milling and 3D-Printing Methods
Abstract Objective Digital complete denture fabrication can be accomplished by either milling or three-dimensional (3D)-printing approach in which minimal distortion duri...

Back to Top