Characterisation of blink dynamics using a high‐speed infrared imaging system
View through CrossRef
Abstract
Purpose
Development and validation of a non‐invasive imaging system to capture spontaneous blinking and characterise blink dynamics using a custom image analysis algorithm.
Methods
A pilot study investigated the influence of illumination type on blink dynamics. Spontaneous blinking was recorded in eight subjects using a high‐speed camera under two illumination conditions: white light and infrared. Custom semi‐automated software assessed palpebral aperture height (PAH), blink rate, blink speed, blink completeness and blink duration. The main clinical study compared two different image analysis techniques. Spontaneous blinking was recorded in 20 subjects using a high‐speed infrared camera. Blink speed and duration were determined using two techniques: manual tracking and semi‐automated tracking. Agreement between the two techniques was assessed using Bland‐Altman analysis. Coefficients of repeatability (COR) were calculated for the semi‐automated technique.
Results
There were significant differences between white light and infrared illumination for PAH (
p
< 0.0001), blink rate (
p
= 0.04), closing speed (
p
= 0.009), opening speed (
p
< 0.0001) and blink duration (
p
= 0.0003). The mean differences (95% limits of agreement) between the two techniques were 0.6 mm s
−1
(−15.9 to 17.0) closing speed, 1.5 mm s
−1
(−6.8 to 9.8) opening speed, 2.4 ms (−6.8 to 11.5) closed phase duration and 5.0 ms (−19.4 to 29.3) total blink duration. COR values were 10.1 mm s
−1
closing speed, 3.7 mm s
−1
opening speed, 6.7 ms closed phase duration and 11.2 ms total blink duration.
Conclusions
This study has shown that spontaneous blinking can be characterised using a non‐invasive imaging system. The semi‐automated analysis provides a rapid characterisation of blink dynamics, allowing its application in large‐scale trials in a number of clinical areas.
Springer Science and Business Media LLC
Title: Characterisation of blink dynamics using a high‐speed infrared imaging system
Description:
Abstract
Purpose
Development and validation of a non‐invasive imaging system to capture spontaneous blinking and characterise blink dynamics using a custom image analysis algorithm.
Methods
A pilot study investigated the influence of illumination type on blink dynamics.
Spontaneous blinking was recorded in eight subjects using a high‐speed camera under two illumination conditions: white light and infrared.
Custom semi‐automated software assessed palpebral aperture height (PAH), blink rate, blink speed, blink completeness and blink duration.
The main clinical study compared two different image analysis techniques.
Spontaneous blinking was recorded in 20 subjects using a high‐speed infrared camera.
Blink speed and duration were determined using two techniques: manual tracking and semi‐automated tracking.
Agreement between the two techniques was assessed using Bland‐Altman analysis.
Coefficients of repeatability (COR) were calculated for the semi‐automated technique.
Results
There were significant differences between white light and infrared illumination for PAH (
p
< 0.
0001), blink rate (
p
= 0.
04), closing speed (
p
= 0.
009), opening speed (
p
< 0.
0001) and blink duration (
p
= 0.
0003).
The mean differences (95% limits of agreement) between the two techniques were 0.
6 mm s
−1
(−15.
9 to 17.
0) closing speed, 1.
5 mm s
−1
(−6.
8 to 9.
8) opening speed, 2.
4 ms (−6.
8 to 11.
5) closed phase duration and 5.
0 ms (−19.
4 to 29.
3) total blink duration.
COR values were 10.
1 mm s
−1
closing speed, 3.
7 mm s
−1
opening speed, 6.
7 ms closed phase duration and 11.
2 ms total blink duration.
Conclusions
This study has shown that spontaneous blinking can be characterised using a non‐invasive imaging system.
The semi‐automated analysis provides a rapid characterisation of blink dynamics, allowing its application in large‐scale trials in a number of clinical areas.
Related Results
Quantitative EEG Features and Machine Learning Classifiers for Eye-Blink Artifact Detection: A Comparative Study
Quantitative EEG Features and Machine Learning Classifiers for Eye-Blink Artifact Detection: A Comparative Study
Abstract
Ocular artifact, namely eye-blink artifact, is an unavoidable and one of the most destructive noises in EEG signals. Many solutions were proposed regarding the det...
Quantitative EEG Features and Machine Learning Classifiers for Eye-Blink Artifact Detection: A Comparative Study
Quantitative EEG Features and Machine Learning Classifiers for Eye-Blink Artifact Detection: A Comparative Study
Abstract
Ocular artifact, namely eye-blink artifact, is an inevitable and one of the most destructive noises of EEG signals. Many solutions of detecting the eye-blink artif...
Feature Extraction from Regenerated EEG – A Better Approach for ICA Based Eye Blink Artifact Detection
Feature Extraction from Regenerated EEG – A Better Approach for ICA Based Eye Blink Artifact Detection
Purpose: Independent Component Analysis (ICA) decomposition is a commonly used technique for eye blink artifact detection from Electroencephalogram (EEG) signals. Feature extractio...
Effects of addiction-associated and affective stimuli on the attentional blink in a sample of abstinent opiate dependent patients
Effects of addiction-associated and affective stimuli on the attentional blink in a sample of abstinent opiate dependent patients
The attentional blink reveals the limits of the brain's ability in information processing. It has been extensively studied in people with neurological and psychiatric disturbances ...
Design of high transparent infrared stealth thin films based on FTO/Ag/FTO structure
Design of high transparent infrared stealth thin films based on FTO/Ag/FTO structure
Multi-spectral compatible stealth materials have become an imperative development trend, especially visible and infrared compatible stealth materials have become the most important...
Rancang Bangun Sistem Terapi Infrared Otomatis Untuk Terapi Far-Infrared Pada Spinal Cord
Rancang Bangun Sistem Terapi Infrared Otomatis Untuk Terapi Far-Infrared Pada Spinal Cord
Terapi infrared adalah terapi yang banyak dilakukan dengan memanfaatkan efek panas yang ditimbulkan pada tubuh manusia terutama pada permukaan kulit yang terpapar secara langsung. ...
Blink-induced changes in pupil dynamics are consistent and heritable
Blink-induced changes in pupil dynamics are consistent and heritable
Abstract
Pupil size and blink rates are heritable but the extent to which they interact with one another has not been properly investigated. Though changes in pupil size du...
The distribution of blinkrate among Malawian young adults: a cross-sectional study
The distribution of blinkrate among Malawian young adults: a cross-sectional study
AbstractBlink rate is a critical sign for numerous systemic and ocular conditions in medicine, however, the literature reports varying values for the parameter. Hence, the aim of t...