Javascript must be enabled to continue!
Energy Resolution Studies in Simulation for the IDEA Dual-Readout Calorimeter Prototype
View through CrossRef
Precision measurements of Z, W, and H decays at the next generation of circular lepton colliders will require excellent energy resolution for both electromagnetic and hadronic showers. The resolution is limited by event-to-event fluctuations in the shower development, especially in the hadronic system. Compensating for this effect can greatly improve the achievable energy resolution. Furthermore, the resolution can benefit greatly from the use of particle-flow algorithms, which requires the calorimeters to have a high granularity. The approach of dual-readout calorimetry has emerged as a candidate to fulfil both of these requirements by allowing to reconstruct the fluctuations in the shower development event-by-event and offering a high transverse granularity. An important benchmark of such a calorimeter is the electromagnetic energy resolution; a prototype of the IDEA calorimeter has been built for use in testbeams. In parallel, a simulation of this prototype has been developed in Geant4 for a testbeam environment. Here, we outline how this simulation was used to study the electromagnetic energy resolution and conclude that a resolution of 14%/E is achievable.
Title: Energy Resolution Studies in Simulation for the IDEA Dual-Readout Calorimeter Prototype
Description:
Precision measurements of Z, W, and H decays at the next generation of circular lepton colliders will require excellent energy resolution for both electromagnetic and hadronic showers.
The resolution is limited by event-to-event fluctuations in the shower development, especially in the hadronic system.
Compensating for this effect can greatly improve the achievable energy resolution.
Furthermore, the resolution can benefit greatly from the use of particle-flow algorithms, which requires the calorimeters to have a high granularity.
The approach of dual-readout calorimetry has emerged as a candidate to fulfil both of these requirements by allowing to reconstruct the fluctuations in the shower development event-by-event and offering a high transverse granularity.
An important benchmark of such a calorimeter is the electromagnetic energy resolution; a prototype of the IDEA calorimeter has been built for use in testbeams.
In parallel, a simulation of this prototype has been developed in Geant4 for a testbeam environment.
Here, we outline how this simulation was used to study the electromagnetic energy resolution and conclude that a resolution of 14%/E is achievable.
Related Results
Strip-based Scintillation Detector for Dual-readout High-granularity Calorimetry
Strip-based Scintillation Detector for Dual-readout High-granularity Calorimetry
New calorimeter technology is being developed for future collider experiments. We are developing a calorimeter that integrates two technologies, a high-granularity calorimeter and ...
Development of High-Granularity Dual-Readout Calorimetry with psec Timing
Development of High-Granularity Dual-Readout Calorimetry with psec Timing
Dual-readout and particle flow algorithm (PFA) are technologies proposed for precise jet energy measurement in future colliders. While PFA requires highly granular calorimeters, du...
Energy response and resolution to positrons in a capillary-tube dual-readout calorimeter prototype
Energy response and resolution to positrons in a capillary-tube dual-readout calorimeter prototype
Abstract
We present the results of a test beam campaign on a
capillary-tube fibre-based dual-readout calorimeter, designed for
precise hadronic and electromagnet...
When Does a Dual Matrix Have a Dual Generalized Inverse?
When Does a Dual Matrix Have a Dual Generalized Inverse?
This paper deals with the existence of various types of dual generalized inverses of dual matrices. New and foundational results on the necessary and sufficient conditions for vari...
Designing Calorimeter Made from Various Wastes
Designing Calorimeter Made from Various Wastes
<p>A research has been conducted which aims to design a waste-based calorimeter as an alternative to measuring heat for chemistry practicum in schools. Research products deve...
Feasibility of energy-resolved angiography
Feasibility of energy-resolved angiography
<p dir="ltr">Cardiovascular disease (CVD) is the leading cause of death globally, with coronary heart disease being one of the most common types of CVD. Two-dimensional x-ray...
Feasibility of energy-resolved angiography
Feasibility of energy-resolved angiography
<p dir="ltr">Cardiovascular disease (CVD) is the leading cause of death globally, with coronary heart disease being one of the most common types of CVD. Two-dimensional x-ray...
Collaborative Promotion:A New Path for the Development of Dual-Innovation Education in Colleges and Universities in Ethnic Minority Area
Collaborative Promotion:A New Path for the Development of Dual-Innovation Education in Colleges and Universities in Ethnic Minority Area
In the context of the new era, talent is the first resource and innovation is the first driving force, and it is more and more important to emphasize the dual-creation education in...

