Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Statistical and superposed epoch study of dipolarization events using data from Wind perigee passes

View through CrossRef
Abstract. From 1995 to 2000, the Wind spacecraft spent over 500h in the magnetotail, much of it within ~2x104km of the predicted location of the neutral sheet. Wind passed through the near magnetotail at distances of -15 RE<X GSM<-6 RE on 35 occasions. Another 10 passes took place at distances of -30 RE<X GSM<-15 RE. We identified 65 dipolarization events in the Wind magnetic field data set between Y GSM~-16 and +16 RE based upon our requirements that the magnetic field inclination had to change by more than 15°, the maximum inclination angle had to be greater than 20°, and the inclination angle had to increase by a factor of at least 1.5. Most of the dipolarization events occurred in the pre-midnight region of the magnetotail and were accompanied by earthward flows with speeds greater than 100km/s. The properties of the dipolarization events did not depend upon the Y GSM position. However, they did vary with the distance to the neutral sheet. Isolated dipolarization events, defined as occurring more than 20min apart, were characterized by a decrease in Bx GSM and BTOTAL, and an increase in Bz GSM and the magnetic field inclination. Dipolarizations that occurred as part of a series of small dipolarizations spaced less than 20min apart were characterized by a transient increase in Bz GSM and the magnetic field inclination, but no significant change in Bx GSM and BTOTAL. The events consisting of a series of small dipolarizations occurred predominantly near midnight. We interpret these results in terms of two different modes of magnetotail convection: 1) a classical substorm pattern featuring storage of magnetic energy in the tail lobes which is explosively released at onset, and 2) a directly driven process.
Title: Statistical and superposed epoch study of dipolarization events using data from Wind perigee passes
Description:
Abstract.
From 1995 to 2000, the Wind spacecraft spent over 500h in the magnetotail, much of it within ~2x104km of the predicted location of the neutral sheet.
Wind passed through the near magnetotail at distances of -15 RE<X GSM<-6 RE on 35 occasions.
Another 10 passes took place at distances of -30 RE<X GSM<-15 RE.
We identified 65 dipolarization events in the Wind magnetic field data set between Y GSM~-16 and +16 RE based upon our requirements that the magnetic field inclination had to change by more than 15°, the maximum inclination angle had to be greater than 20°, and the inclination angle had to increase by a factor of at least 1.
5.
Most of the dipolarization events occurred in the pre-midnight region of the magnetotail and were accompanied by earthward flows with speeds greater than 100km/s.
The properties of the dipolarization events did not depend upon the Y GSM position.
However, they did vary with the distance to the neutral sheet.
Isolated dipolarization events, defined as occurring more than 20min apart, were characterized by a decrease in Bx GSM and BTOTAL, and an increase in Bz GSM and the magnetic field inclination.
Dipolarizations that occurred as part of a series of small dipolarizations spaced less than 20min apart were characterized by a transient increase in Bz GSM and the magnetic field inclination, but no significant change in Bx GSM and BTOTAL.
The events consisting of a series of small dipolarizations occurred predominantly near midnight.
We interpret these results in terms of two different modes of magnetotail convection: 1) a classical substorm pattern featuring storage of magnetic energy in the tail lobes which is explosively released at onset, and 2) a directly driven process.

Related Results

Wind lidars within Dutch offshore wind farms
Wind lidars within Dutch offshore wind farms
The growing number of wind farms in the Dutch part of the North Sea [1] offers the necessity, as well as the opportunity, to measure the meteorological conditions at these location...
Solar wind interaction with comet 67P around perihelion
Solar wind interaction with comet 67P around perihelion
AbstractNear perihelion, when comet 67P was most active, the Rosetta spacecraft resided inside the comet induced magnetosphere. The solar wind magnetic field was still present, but...
Analysis of Senegal Type Vertical Axis Wind Turbines Arrangement in Wind Farm
Analysis of Senegal Type Vertical Axis Wind Turbines Arrangement in Wind Farm
Background: In a wind farm, the wind speed of the downstream wind turbine will be lower than the wind speed of the upstream wind turbine due to the influence of the wake. Therefore...
Savonius Rotor for Offshore Wind Energy Conversion
Savonius Rotor for Offshore Wind Energy Conversion
Abstract Analysis of performance is presented for wind energy conversion by a Savonius type vertical axis rotor configured for generation of electrical power. The...
Interannual variability of wind climates and wind turbine annual energy production
Interannual variability of wind climates and wind turbine annual energy production
Abstract. The interannual variability (IAV) of expected annual energy production (AEP) from proposed wind farms plays a key role in dictating project financing. IAV in preconstruct...
Outcomes of Treatment With CHOP and EPOCH in Patients With HIV Associated NHL in a Low Resource Setting
Outcomes of Treatment With CHOP and EPOCH in Patients With HIV Associated NHL in a Low Resource Setting
Abstract Background: The optimal chemotherapy regimen for treating HIV associated NHL in low resource settings is unknown. We conducted a retrospective study to describe su...
Performance Test and Simulation Study on the Air Path of CAP1400 Passive Containment Cooling System
Performance Test and Simulation Study on the Air Path of CAP1400 Passive Containment Cooling System
As a large scale passive pressurized water reactor nuclear power plant, CAP1400 can remove the reactor decay heat to outside containment with the air cooling in the air flow path o...
Design and Performance Analysis of Distributed Equal Angle Spiral Vertical Axis Wind Turbine
Design and Performance Analysis of Distributed Equal Angle Spiral Vertical Axis Wind Turbine
Background: The wind turbine is divided into a horizontal axis and a vertical axis depending on the relative positions of the rotating shaft and the ground. The advantage of the ch...

Back to Top