Modeling of the Mutual Placement of Thermoanemometer Sensors on a Flat Surface of an Air Flow

View through CrossRef
A functional model of a thermoanemometer measuring the air flow velocity on a flat wall surface of the flow has been developed. From the heat balance equation of the sensing elements in the thermoanemometer, a dependence has been derived for determining the heating temperature of the sensing elements. The distribution of the temperature field in the boundary layer was modeled by analogy with the velocity distribution, following a cubic dependence. The distribution of the temperature field on a flat wall surface of the flow from the heating of the sensing elements was obtained analytically by solving the heat conduction equation in the direction of the coordinate of the air flow velocity vector for the boundary conditions of the II as well as II and III kinds. The developed mathematical dependencies enable both the modeling of the distribution of temperature fields in the sensing elements and justifying the distance between them. The reliability of measurements of the air flow velocity on the wall surface of the flow depends on the impossibility of influencing the temperature of one sensing element of the sensor on the temperature of the other. The task of justifying the distance between the sensing elements of the sensor, which are located in the direction of the air flow velocity vector, aims to prevent the interaction of the temperature fields of the elements with each other. The boundary condition is that at the boundary of separation between the temperature fields of the sensing elements, there is a temperature that is 5 to 10% lower than the temperature of the colder sensing element. The ratio of the resistances of the sensing elements is 4/1. The power released by the first sensing element of the sensor, aligned along the air flow velocity vector, is 4 times lower than the heating power of the second sensing element of the sensor. The modeling was carried out at an air flow velocity within 30 and 330 m·s−1. The values of the distances between the sensing elements of the thermal anemometer vary with the supply voltage. The material of the sensing elements is nickel. The contact area of the surface of the sensing elements was 214.337 mm2.
Title: Modeling of the Mutual Placement of Thermoanemometer Sensors on a Flat Surface of an Air Flow
Description:
A functional model of a thermoanemometer measuring the air flow velocity on a flat wall surface of the flow has been developed.
From the heat balance equation of the sensing elements in the thermoanemometer, a dependence has been derived for determining the heating temperature of the sensing elements.
The distribution of the temperature field in the boundary layer was modeled by analogy with the velocity distribution, following a cubic dependence.
The distribution of the temperature field on a flat wall surface of the flow from the heating of the sensing elements was obtained analytically by solving the heat conduction equation in the direction of the coordinate of the air flow velocity vector for the boundary conditions of the II as well as II and III kinds.
The developed mathematical dependencies enable both the modeling of the distribution of temperature fields in the sensing elements and justifying the distance between them.
The reliability of measurements of the air flow velocity on the wall surface of the flow depends on the impossibility of influencing the temperature of one sensing element of the sensor on the temperature of the other.
The task of justifying the distance between the sensing elements of the sensor, which are located in the direction of the air flow velocity vector, aims to prevent the interaction of the temperature fields of the elements with each other.
The boundary condition is that at the boundary of separation between the temperature fields of the sensing elements, there is a temperature that is 5 to 10% lower than the temperature of the colder sensing element.
The ratio of the resistances of the sensing elements is 4/1.
The power released by the first sensing element of the sensor, aligned along the air flow velocity vector, is 4 times lower than the heating power of the second sensing element of the sensor.
The modeling was carried out at an air flow velocity within 30 and 330 m·s−1.
The values of the distances between the sensing elements of the thermal anemometer vary with the supply voltage.
The material of the sensing elements is nickel.
The contact area of the surface of the sensing elements was 214.
337 mm2.

Related Results

Air convection in coarse blocky permafrost : a numerical modelling approach to improve the understanding of the ground thermal regime
Air convection in coarse blocky permafrost : a numerical modelling approach to improve the understanding of the ground thermal regime
Permafrost is a thermal phenomenon, defined as subsurface material with a temperature remaining below 0°C for at least two consecutive years. Permafrost occurs at high latitudes an...
Optimization of The Portfolio of Financial Institution Pension Funds in Indonesia Using the Response Surface Methodology
Optimization of The Portfolio of Financial Institution Pension Funds in Indonesia Using the Response Surface Methodology
Investments in pension funds consist of government bonds, deposits, bonds, shares, mutual funds, and other investments. Pension funds consist of the Employer Pension Fund (EPF) and...
Mars Reconnaissance Orbiter Context Camera updated in-flight calibration
Mars Reconnaissance Orbiter Context Camera updated in-flight calibration
Introduction: The Context Camera (CTX) has so far delivered more than 145,000 images [1]. The images are one of the most popular datasets for planetary geologists, providing extens...
Large Scale PWR Passive Containment Cooling System Wind Tunnel Test
Large Scale PWR Passive Containment Cooling System Wind Tunnel Test
CAP1400 is a large passive pressurized water reactor nuclear power plant, which relies on engineering safety features such as passive containment cooling system (PCS) to remove the...
Removal of toxic vapors by oxidation: Development of laboratory test procedures for in-duct air cleaning systems
Removal of toxic vapors by oxidation: Development of laboratory test procedures for in-duct air cleaning systems
Exposure to volatile organic compounds (VOC) in workplaces can cause acute effects such as irritation of the skin, the eyes, the mouth, and the nose. Some products may also cause c...
Study of Honeycomb Air Curtain for a Freezer Room to Enhance Protection against Warm Air Infiltration
Study of Honeycomb Air Curtain for a Freezer Room to Enhance Protection against Warm Air Infiltration
The objective of this research is to present the energy-saving effect of applying an air curtain to prevent the penetration of warm air through a freezer door. Retail business is h...
British Food Journal Volume 44 Issue 12 1942
British Food Journal Volume 44 Issue 12 1942
Heat also facilitates the transmission of water through the cell walls, thereby assisting its passage from the interior to the surface of the material; it increases the vapour pres...

Back to Top