Javascript must be enabled to continue!
THE DOSIMETRIC COMPARISON BETWEEN TANDEM OVOID AND TANDEM RING APPLICATOR IN CERVICAL CANCER BRACHYTHERAPY
View through CrossRef
AIM: The present research aims to assess the differences in dosimetry between tandem-ovoid and tandem-ring gynaecologic brachytherapy applicators utilizing diverse optimizing techniques in image-based brachytherapy.
Background: Conventionally, tandem ovoid applicators were utilized to deliver doses to tumor in intracavitary brachytherapy. Currently various types of applicators are accessible for cervical cancer brachytherapy management such as Tandem-ring, tandem-cylinder, and hybrid intracavitary, interstitial applicators.
Material and methods: We utilized a tandem-ring and Fletcher-style tandem-ovoid applicator in the same patients (30) in two fractions of brachytherapy. Four plans were generated for every patient utilizing 2 optimization techniques for all applicator utilized. A dose of 9 Gy was prescribed and plans were regulates to left point A and in previous methods, the optimization is done to attain the optional OAR dose-volume restraints. Dose-volume and dose point parameters were evaluated.
Results: For Point A normalized plan both Bladder and Sigmoid are superior in TO applicator than TR applicator but not statistically significant and the rectum doses are superior in TR applicator than TO applicator and statistically significant. When we evaluate both the optimization methods the difference is measured to be not statistically significant.
Conclusions: The findings specify that the OAR doses considerd by DVH criteria were lesser than ICRU point doses for the bladder and rectum with both tandem-ovoid and tandem-ring applicators for Point A normalized plans. The ICRU Bladder Point and rectum point doses are lesser in OAR optimized plans than in Point A normalized plans in both applicators. The 90%,100%,200 % isodose volumes are superior in Point A normalized plans than in OAR-based optimized plans in both applicators.
Keywords: Cervix cancer, Brachytherapy, Applicators, Optimization techniques, Dosimetry, tandem-ring, tandem-oviod
Title: THE DOSIMETRIC COMPARISON BETWEEN TANDEM OVOID AND TANDEM RING APPLICATOR IN CERVICAL CANCER BRACHYTHERAPY
Description:
AIM: The present research aims to assess the differences in dosimetry between tandem-ovoid and tandem-ring gynaecologic brachytherapy applicators utilizing diverse optimizing techniques in image-based brachytherapy.
Background: Conventionally, tandem ovoid applicators were utilized to deliver doses to tumor in intracavitary brachytherapy.
Currently various types of applicators are accessible for cervical cancer brachytherapy management such as Tandem-ring, tandem-cylinder, and hybrid intracavitary, interstitial applicators.
Material and methods: We utilized a tandem-ring and Fletcher-style tandem-ovoid applicator in the same patients (30) in two fractions of brachytherapy.
Four plans were generated for every patient utilizing 2 optimization techniques for all applicator utilized.
A dose of 9 Gy was prescribed and plans were regulates to left point A and in previous methods, the optimization is done to attain the optional OAR dose-volume restraints.
Dose-volume and dose point parameters were evaluated.
Results: For Point A normalized plan both Bladder and Sigmoid are superior in TO applicator than TR applicator but not statistically significant and the rectum doses are superior in TR applicator than TO applicator and statistically significant.
When we evaluate both the optimization methods the difference is measured to be not statistically significant.
Conclusions: The findings specify that the OAR doses considerd by DVH criteria were lesser than ICRU point doses for the bladder and rectum with both tandem-ovoid and tandem-ring applicators for Point A normalized plans.
The ICRU Bladder Point and rectum point doses are lesser in OAR optimized plans than in Point A normalized plans in both applicators.
The 90%,100%,200 % isodose volumes are superior in Point A normalized plans than in OAR-based optimized plans in both applicators.
Keywords: Cervix cancer, Brachytherapy, Applicators, Optimization techniques, Dosimetry, tandem-ring, tandem-oviod.
Related Results
Differences of Ring Applicator Reconstruction Methods in Brachytherapy
Differences of Ring Applicator Reconstruction Methods in Brachytherapy
Purpose: Analysis and comparison of existing reconstruction methods of the ring applicator, as well as the development of reconstruction method that is closest to the actual source...
Pain and Complications Assessment in Gynecological Cancer Brachytherapy Patients Under Spinal Anesthesia
Pain and Complications Assessment in Gynecological Cancer Brachytherapy Patients Under Spinal Anesthesia
Background: Brachytherapy is a radiation therapy that can deliver radiation to cancer by minimizing radiation exposure to adjacent organs or tissues. In its implementation, brachyt...
THE ROLE OF HYBRID BRACHYTHERAPY IN MANAGEMENT OF LOCALLY ADVANCED CERVICAL CANCER: DOSIMETRIC STUDY AND INITIAL RESULTS
THE ROLE OF HYBRID BRACHYTHERAPY IN MANAGEMENT OF LOCALLY ADVANCED CERVICAL CANCER: DOSIMETRIC STUDY AND INITIAL RESULTS
Purpose:The aims of this study were to investigate the clinical feasibility and to report our preliminary treatment outcomes of combined intracavitary/interstitial brachytherapy (I...
TATA LAKSANA BRAKHITERAPI CO-60 TEKNIK INTRAKAVITER LENGKAP PADA KASUS KANKER SERVIKS
TATA LAKSANA BRAKHITERAPI CO-60 TEKNIK INTRAKAVITER LENGKAP PADA KASUS KANKER SERVIKS
Background: Brachytherapy is a radiation treatment by bringing radiation sources closer to the primary tumor which aims to provide additional therapeutic doses (booster) after exte...
Cervical cancer screening utilization and predictors among eligible women in Ethiopia: A systematic review and meta-analysis
Cervical cancer screening utilization and predictors among eligible women in Ethiopia: A systematic review and meta-analysis
BackgroundDespite a remarkable progress in the reduction of global rate of maternal mortality, cervical cancer has been identified as the leading cause of maternal morbidity and mo...
THE ROLE OF HYBRID BRACHYTHERAPY IN MANAGEMENT OF LOCALLY ADVANCED CERVICAL CANCER: DOSIMETRIC STUDY AND INITIAL RESULTS
THE ROLE OF HYBRID BRACHYTHERAPY IN MANAGEMENT OF LOCALLY ADVANCED CERVICAL CANCER: DOSIMETRIC STUDY AND INITIAL RESULTS
Purpose: The aims of this study were to investigate the clinical feasibility and to report our preliminary treatment outcomes of combined intracavitary/interstitial brachytherapy (...
Nasopharyngeal intracavitary brachytherapy
Nasopharyngeal intracavitary brachytherapy
AbstractBACKGROUNDLocally persistent nasopharyngeal carcinoma (NPC) carries an increased risk of local failure if additional treatment is not given. It has been shown that intracav...
Is Advanced Age a Limiting Factor in the Practice of High Dose Rate Brachytherapy in Patients Treated for Cervical Cancer?
Is Advanced Age a Limiting Factor in the Practice of High Dose Rate Brachytherapy in Patients Treated for Cervical Cancer?
Purpose:
To assess the percentage of elderly patients not receiving brachytherapy in our practice and identify the factors
influencing the decision to forgo this therapeutic modali...

