Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Long‐Term Stapedectomy Results With the McGee Stapes Prosthesis

View through CrossRef
AbstractObjective To report long‐term follow up on patients undergoing stapedectomy with the McGee stapes prosthesis.Study Design A retrospective case series.Methods Charts recording 170 stapedectomies (120 primary and 50 revision stapedectomies) from 1989 to 1999 were analyzed, and audiometric data and the findings at repeat exploration reported.Results Over a 10‐year period, 11.2% of patients had failure of their initial air‐bone gap closure with the McGee piston. Seventy‐seven percent (in 10 of 13 patients) of McGee pistons that failed were found to have the platinum ribbon displaced laterally from the incus and the piston pushed out of the stapedotomy. The failure rate was not significantly different (P = .72) from that in our patients who underwent placement of a Robinson cup prosthesis (9.5%), but the pattern of displacement was unique. Failures occurred earlier with the McGee piston (average time to failure of 2.5 y) than with the Robinson cup (average time to failure of 8.6 y).Conclusion The McGee piston was found to have a unique pattern of dislocation that is likely related to the malleable nature of the platinum ribbon and loosening of the crimped “shepherd's crook” over time.
Title: Long‐Term Stapedectomy Results With the McGee Stapes Prosthesis
Description:
AbstractObjective To report long‐term follow up on patients undergoing stapedectomy with the McGee stapes prosthesis.
Study Design A retrospective case series.
Methods Charts recording 170 stapedectomies (120 primary and 50 revision stapedectomies) from 1989 to 1999 were analyzed, and audiometric data and the findings at repeat exploration reported.
Results Over a 10‐year period, 11.
2% of patients had failure of their initial air‐bone gap closure with the McGee piston.
Seventy‐seven percent (in 10 of 13 patients) of McGee pistons that failed were found to have the platinum ribbon displaced laterally from the incus and the piston pushed out of the stapedotomy.
The failure rate was not significantly different (P = .
72) from that in our patients who underwent placement of a Robinson cup prosthesis (9.
5%), but the pattern of displacement was unique.
Failures occurred earlier with the McGee piston (average time to failure of 2.
5 y) than with the Robinson cup (average time to failure of 8.
6 y).
Conclusion The McGee piston was found to have a unique pattern of dislocation that is likely related to the malleable nature of the platinum ribbon and loosening of the crimped “shepherd's crook” over time.

Related Results

Stapedotomy or Stapedectomy: Does It Really Matter?
Stapedotomy or Stapedectomy: Does It Really Matter?
Abstract Introduction Otosclerosis leads to stapes fixation and consequent conductive hearing loss. Surgery is the mainstay of treatment, and it can be achieved through s...
Sound transmission by chamber prosthesis of the middle ear
Sound transmission by chamber prosthesis of the middle ear
Abstract Tests done on specimens cut from the temporal bones show, that the stapedotomy can be more effective, if instead of the piston prosthesis, the ear chamber ...
Tympanoplasty with an Intact Stapes Superstructure in Chronic Otitis Media
Tympanoplasty with an Intact Stapes Superstructure in Chronic Otitis Media
BACKGROUND: The objective of our study was to ascertain the functional results in terms of air bone gap (ABG) closure over 4 frequencies (0.5, 1, 2, 3 kHz) in patients with chronic...
Experience with Stapedectomy in a Developing Country: A Review of 200 Cases
Experience with Stapedectomy in a Developing Country: A Review of 200 Cases
Since stapedectomy was first performed in 1956, many innovations have been described. We retrospectively analyzed 200 cases of stapedectomy that had been performed with standard ot...
Penile prosthesis – a viable solution for erectile dysfunction refractory to conservative therapy
Penile prosthesis – a viable solution for erectile dysfunction refractory to conservative therapy
Introduction: Erectile dysfunction(ED) is a serious condition which can affect men of all ages, with an important impact over the quality of life. When conservative therapy fails,...

Back to Top