Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Ocular Biometric Values and Prevalence of Corneal Astigmatism in Patients Candidate for Cataract Surgery

View through CrossRef
Purpose:To analyze the biometric values and the prevalence of corneal astigmatism in cataract surgery candidates.Methods:This is a prospective study. Ocular biometric values and corneal keratometric astigmatism were measured by optical low-coherence reflectometry (Lenstar LS 900) before surgery in patients who were candidates for cataract extraction surgery. Descriptive measurements of biometric dimensions and keratometric cylinder data and their correlations with sex and age were evaluated.Results:Ocular biometric and keratometric values from 2084 eyes of 2084 patients (mean age 66.43, range 19–95 years) were analyzed. The mean values were as follows: corneal astigmatism 0.89 diopter (D), mean corneal keratometry 44.29 D, central corneal thickness 534 μ, internal anterior chamber depth (ACD) 3.11 mm, lens thickness 4.50 mm, and axial length 23.35 mm. Corneal astigmatism was <1.25 D in 1660 (79.5%) of eyes. Astigmatism was with-the-rule in 976 (46.8%) of eyes, against-the-rule (ATR) in 702 (33.7%), and oblique in 406 (19.5%). Analysis of corneal astigmatism revealed a change toward “ATR” with age which was not statistically significant. The ACD was correlated with age. The amount of corneal astigmatism had no correlation with age and sex.Conclusion:Corneal astigmatism was higher than 1.25 D in about 21% of cataract surgery candidates with slight differences between the various age ranges and had no correlation with age and sex.
Title: Ocular Biometric Values and Prevalence of Corneal Astigmatism in Patients Candidate for Cataract Surgery
Description:
Purpose:To analyze the biometric values and the prevalence of corneal astigmatism in cataract surgery candidates.
Methods:This is a prospective study.
Ocular biometric values and corneal keratometric astigmatism were measured by optical low-coherence reflectometry (Lenstar LS 900) before surgery in patients who were candidates for cataract extraction surgery.
Descriptive measurements of biometric dimensions and keratometric cylinder data and their correlations with sex and age were evaluated.
Results:Ocular biometric and keratometric values from 2084 eyes of 2084 patients (mean age 66.
43, range 19–95 years) were analyzed.
The mean values were as follows: corneal astigmatism 0.
89 diopter (D), mean corneal keratometry 44.
29 D, central corneal thickness 534 μ, internal anterior chamber depth (ACD) 3.
11 mm, lens thickness 4.
50 mm, and axial length 23.
35 mm.
Corneal astigmatism was <1.
25 D in 1660 (79.
5%) of eyes.
Astigmatism was with-the-rule in 976 (46.
8%) of eyes, against-the-rule (ATR) in 702 (33.
7%), and oblique in 406 (19.
5%).
Analysis of corneal astigmatism revealed a change toward “ATR” with age which was not statistically significant.
The ACD was correlated with age.
The amount of corneal astigmatism had no correlation with age and sex.
Conclusion:Corneal astigmatism was higher than 1.
25 D in about 21% of cataract surgery candidates with slight differences between the various age ranges and had no correlation with age and sex.

Related Results

Symmetrical femtosecond laser arc incision in correcting corneal astigmatism in cataract patients
Symmetrical femtosecond laser arc incision in correcting corneal astigmatism in cataract patients
AIM: To evaluate the effect of symmetrical arc incision correcting corneal astigmatism in femtosecond laser-assisted phacoemulsification (FLACS). METHODS: This study enrolled patie...
EFFECT OF SUPEROTEMPORAL CLEAR CORNEAL INCISION ON PRE EXISTING ASTIGMATISM AFTER PHACOEMUSIFICATION SURGERY
EFFECT OF SUPEROTEMPORAL CLEAR CORNEAL INCISION ON PRE EXISTING ASTIGMATISM AFTER PHACOEMUSIFICATION SURGERY
Background: Historically, patients undergoing cataract surgery were at an increased risk of developing surgically induced astigmatism with the advent of modern methods of cataract ...
Changes in Vector Astigmatism After Superotemporal Versus Temporal Clear Corneal Incision Cataract Surgery
Changes in Vector Astigmatism After Superotemporal Versus Temporal Clear Corneal Incision Cataract Surgery
Purpose To investigate vector and refractive astigmatism changes after superotemporal versus temporal clear corneal incision cataract surgery. Methods Patients were diagnosed with ...
Toric Intraocular Lens Implantation in Cataract Patients with Corneal Opacity
Toric Intraocular Lens Implantation in Cataract Patients with Corneal Opacity
AbstractAimsTo evaluate the effect of toric intraocular lens implantation in cataract patient with corneal opacity and high astigmatism.Methods31 eyes of 31 patients who underwent ...
Toric Intraocular Lens Implantation in Cataract Patients with Corneal Opacity.
Toric Intraocular Lens Implantation in Cataract Patients with Corneal Opacity.
Abstract Purpose: To evaluate the effect of toric intraocular lens implantation in cataract patient with corneal opacity and high astigmatism. Methods: 31 eyes of 31 patien...
Toric Intraocular Lens Implantation in Cataract Patients with Corneal Opacity.
Toric Intraocular Lens Implantation in Cataract Patients with Corneal Opacity.
Abstract Purpose: To evaluate the effect of toric intraocular lens implantation in cataract patient with corneal opacity and high astigmatism. Methods: 31 eyes of 31 patie...
Toric Intraocular Lens Implantation in Cataract Patients with Corneal Opacity.
Toric Intraocular Lens Implantation in Cataract Patients with Corneal Opacity.
Abstract Purpose: To evaluate the effect of toric intraocular lens implantation in cataract patient with corneal opacity and high astigmatism. Methods: 31 eyes of 31 patien...
Toric Intraocular Lens Implantation in Cataract Patients with Corneal Opacity
Toric Intraocular Lens Implantation in Cataract Patients with Corneal Opacity
Abstract Background: To evaluate the effect of toric intraocular lens implantation in cataract patient with corneal opacity and high astigmatism. Methods: 31 eyes of 31 pat...

Back to Top