Javascript must be enabled to continue!
A Seventeen Multilevel High-Power Application Inverter with Low Total Harmonic Distortion
View through CrossRef
In this paper, a new topology of multilevel inverter (MLI) is designed with a fewer number of components and low total harmonic distortion (THD) for high-power photovoltaic (PV) systems. The key limitations of conventional MLI topologies are high total harmonic distortion (THD) and the use of a large number of switching components due to which the cost of the overall inverter is high. In conventional MLI, THD can be significantly reduced by the addition of a large value filter element at the input side; however, it will result in increased size and cost. Thus, achieving a pure sinusoidal AC at the output and to maintain a low THD level is a major issue in conventional MLIs. The proposed MLI has the advantage of decreasing the output THD by using a modified form of the cascaded H-Bridge structure and sine pulse width modulation technique. The proposed inverter consists of 6 unidirectional switches and 2 bidirectional switches, and there is no extra requirement for additional voltage balancing capacitors or clinching diodes. The individual switching states and SPWM operation for generating the gate pulses of the proposed MLI are discussed in detail. Relevant waveforms are plotted, equations are derived, and mathematical analysis is carried out. A steady-state analysis of the proposed MLI demonstrates an output voltage with 17 levels while using only four DC sources. Simulation results of the proposed MLI for single-phase and three-phase structures are obtained, and comparison is carried out with existing MLI topologies which shows that the proposed MLI has significantly low THD and better performance. From the results, it is clear that the proposed MLI has a THD of 3.52% in comparison with four conventional MLIs whose THDs are 6.1%, 6.63%, 7.3%, and 9.93%. Moreover, the proposed MLI generates 17 voltage levels by using only 08 switching devices, whereas the conventional MLIs use more than 10 switching devices for the generation of 15 voltage levels.
Title: A Seventeen Multilevel High-Power Application Inverter with Low Total Harmonic Distortion
Description:
In this paper, a new topology of multilevel inverter (MLI) is designed with a fewer number of components and low total harmonic distortion (THD) for high-power photovoltaic (PV) systems.
The key limitations of conventional MLI topologies are high total harmonic distortion (THD) and the use of a large number of switching components due to which the cost of the overall inverter is high.
In conventional MLI, THD can be significantly reduced by the addition of a large value filter element at the input side; however, it will result in increased size and cost.
Thus, achieving a pure sinusoidal AC at the output and to maintain a low THD level is a major issue in conventional MLIs.
The proposed MLI has the advantage of decreasing the output THD by using a modified form of the cascaded H-Bridge structure and sine pulse width modulation technique.
The proposed inverter consists of 6 unidirectional switches and 2 bidirectional switches, and there is no extra requirement for additional voltage balancing capacitors or clinching diodes.
The individual switching states and SPWM operation for generating the gate pulses of the proposed MLI are discussed in detail.
Relevant waveforms are plotted, equations are derived, and mathematical analysis is carried out.
A steady-state analysis of the proposed MLI demonstrates an output voltage with 17 levels while using only four DC sources.
Simulation results of the proposed MLI for single-phase and three-phase structures are obtained, and comparison is carried out with existing MLI topologies which shows that the proposed MLI has significantly low THD and better performance.
From the results, it is clear that the proposed MLI has a THD of 3.
52% in comparison with four conventional MLIs whose THDs are 6.
1%, 6.
63%, 7.
3%, and 9.
93%.
Moreover, the proposed MLI generates 17 voltage levels by using only 08 switching devices, whereas the conventional MLIs use more than 10 switching devices for the generation of 15 voltage levels.
Related Results
Modeling of A Single Phase 7-Level Cascaded H-Bridge Multilevel Inverter
Modeling of A Single Phase 7-Level Cascaded H-Bridge Multilevel Inverter
Recently, almost all industrial devices are mostly built on electronic devices which are precisely sensitive to harmonic. In order to meet the requirement from the industries deman...
Three Phase Eleven Level Modular Multilevel Inverter with PD-PWM for Grid Connected System
Three Phase Eleven Level Modular Multilevel Inverter with PD-PWM for Grid Connected System
The prominence of Modular Multilevel Inverters (MMI) is rising owing their merits of simple mechanical
construction and good voltage sharing for semiconductor devices. Mostly Multi...
7 level symmetrical inverter for photovoltaic system
7 level symmetrical inverter for photovoltaic system
This research presents the design, implementation, and evaluation of a seven-level symmetrical inverter for photovoltaic systems. The inverter is based on a cascaded H-bridges topo...
Design of Control Secheme and Performance Improvement for Multilevel Dc Link Inverter Fed PMBLDC Motor Drive
Design of Control Secheme and Performance Improvement for Multilevel Dc Link Inverter Fed PMBLDC Motor Drive
PMBLDC motors are gaining a lot of popularity due to their high efficiency as the Permanent Magnets do not carry current which results in negligible copper losses as compared to as...
Research On Arbitrary Level Output Topology And Control Strategy
Research On Arbitrary Level Output Topology And Control Strategy
Abstract
Multilevel inverters will generate current backflow and harmonics due to their different inverter topologies in the inverter process. According to a large number o...
A Grid-Tied Fuel Cell Multilevel Inverter with Low Harmonic Distortions
A Grid-Tied Fuel Cell Multilevel Inverter with Low Harmonic Distortions
As a result of global energy demand increase, concerns over global warming, and rapid exhaustion of fossil fuels, there is a growing interest in energy system dependence on clean a...
A New Method of Selective Harmonic Elimination PWM for H-Bridge Cascaded Multilevel Inverter
A New Method of Selective Harmonic Elimination PWM for H-Bridge Cascaded Multilevel Inverter
The quality of power of the cascaded H-bridge multilevel inverter is affected due to harmonics. In this paper, a Selective Harmonic Elimination Pulse Width Modulation (SHE-PWM) met...
Analisis Perbandingan Efisiensi Daya Modified Sine Inverter Dengan Pure Sine Inverter
Analisis Perbandingan Efisiensi Daya Modified Sine Inverter Dengan Pure Sine Inverter
Penyimpangan daya seperti adanya gangguan listrik dapat menyebabkan dampak yang parah pada beban yang sensitif atau penting dalam sistem kelistrikan, sehingga dibutuhkan peralatan ...