Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Laboratory Evaluation of Biosealers

View through CrossRef
Abstract Description of the Paper. Solubility and diameter of biosealers were measured as a function of ionic strength and pH. Solubility tests were conducted using HCl (15 and 28 wt%) and organic acids (10 wt% formic acid, 10 wt% acetic acid and 10 wt% citric acid). To mimic the effect of spent acids on the solubility of biosealers, solubility was also measured in CaCl2 (10 wt%), MgCl2 (10 wt%) and NaCl (10 wt%) brines. These tests were conducted at 75 and 19°F, with soaking times of up to several days. Application. Diversion and efficient sweep are needed during placement of various treatment fluids. Biosealers, which were recently introduced to the oil industry, can be used to direct injected fluids into low permeability zones or plugged perforations. The performance of biosealers depends on their solubility and diameter. It is important to maintain certain characteristics of the biosealers to ensure efficient diversion throughout the treatments. Results, Observations, Conclusions. At 7°F, the weight and diameter of the biosealers monotonically increased with respect to time when placed in distilled water. However, the biosealers continuously dissolved when placed in 15 or 28 wt% HCl solutions. The rate of dissolution of these balls was independent of acid concentration from 15 to 28 wt% HCl. In calcium and magnesium brines, the weight of the biosealers showed an initial increase (swelling) before the biosealers started to dissolve. Unlike room temperature results, the biosealers continuously dissolved at high temperatures in all fluids examined. The rate of dissolution was found to be a function of acid type and ionic strength. Lower dissolution rates were noted when the biosealers were soaked in organic acids. Surfactants (anionic, cationic or nonionic) and mutual solvent reduced swelling of biosealers in distilled water. Corrosion inhibitors, mutual solvent and surfactants (especially the anionic surfactant) reduced the rate of degradation of biosealers in HCl. Significance of Subject Matter: Biosealers are used to divert various fluids during acidizing and other chemical treatments. The results obtained from this study showed that the weight and diameter of biosealer depend on pH, soaking time, temperature, and ionic strength. These factors should be carefully considered when using biosealers to divert acids and other chemicals in the field. Introduction Ball sealers have been used in the oil and gas industry for more than four decades.1 They are used in cased wells to divert treating fluids (hydraulic frac fluids and acids) into low permeability zones and plugged perforations. In a typical treatment, these balls are pumped with the treating fluids. They are supposed to flow with these fluids into the perforations that correspond to high permeability zones. They seat on these perforations and force the treating fluids to enter the low permeability zones. These balls will remain in the perforations during the treatment. However, at the end of the treatment, they will either flow back to the surface with the spent acid or the frac fluids where special devices are used to catch these balls before any choke, or sink to the bottom of the rat hole. Ball sealers are available in different sizes and densities. Selection of the size and density of ball sealers depends on several factors, some of the main ones are: perforation size, perforation density, the length of the target zone, and the density of the treating fluids. Obviously, the effectiveness of ball sealers depends on the seating efficiency of these balls. Ball sealers can be lighter (floater) or heavier (sinker) than the treating fluids. The advantages and disadvantages of each type of ball sealers are discussed by Bilden et al.1 Several research groups addressed methods and factors to enhance the performance of these balls.2–4
Title: Laboratory Evaluation of Biosealers
Description:
Abstract Description of the Paper.
Solubility and diameter of biosealers were measured as a function of ionic strength and pH.
Solubility tests were conducted using HCl (15 and 28 wt%) and organic acids (10 wt% formic acid, 10 wt% acetic acid and 10 wt% citric acid).
To mimic the effect of spent acids on the solubility of biosealers, solubility was also measured in CaCl2 (10 wt%), MgCl2 (10 wt%) and NaCl (10 wt%) brines.
These tests were conducted at 75 and 19°F, with soaking times of up to several days.
Application.
Diversion and efficient sweep are needed during placement of various treatment fluids.
Biosealers, which were recently introduced to the oil industry, can be used to direct injected fluids into low permeability zones or plugged perforations.
The performance of biosealers depends on their solubility and diameter.
It is important to maintain certain characteristics of the biosealers to ensure efficient diversion throughout the treatments.
Results, Observations, Conclusions.
At 7°F, the weight and diameter of the biosealers monotonically increased with respect to time when placed in distilled water.
However, the biosealers continuously dissolved when placed in 15 or 28 wt% HCl solutions.
The rate of dissolution of these balls was independent of acid concentration from 15 to 28 wt% HCl.
In calcium and magnesium brines, the weight of the biosealers showed an initial increase (swelling) before the biosealers started to dissolve.
Unlike room temperature results, the biosealers continuously dissolved at high temperatures in all fluids examined.
The rate of dissolution was found to be a function of acid type and ionic strength.
Lower dissolution rates were noted when the biosealers were soaked in organic acids.
Surfactants (anionic, cationic or nonionic) and mutual solvent reduced swelling of biosealers in distilled water.
Corrosion inhibitors, mutual solvent and surfactants (especially the anionic surfactant) reduced the rate of degradation of biosealers in HCl.
Significance of Subject Matter: Biosealers are used to divert various fluids during acidizing and other chemical treatments.
The results obtained from this study showed that the weight and diameter of biosealer depend on pH, soaking time, temperature, and ionic strength.
These factors should be carefully considered when using biosealers to divert acids and other chemicals in the field.
Introduction Ball sealers have been used in the oil and gas industry for more than four decades.
1 They are used in cased wells to divert treating fluids (hydraulic frac fluids and acids) into low permeability zones and plugged perforations.
In a typical treatment, these balls are pumped with the treating fluids.
They are supposed to flow with these fluids into the perforations that correspond to high permeability zones.
They seat on these perforations and force the treating fluids to enter the low permeability zones.
These balls will remain in the perforations during the treatment.
However, at the end of the treatment, they will either flow back to the surface with the spent acid or the frac fluids where special devices are used to catch these balls before any choke, or sink to the bottom of the rat hole.
Ball sealers are available in different sizes and densities.
Selection of the size and density of ball sealers depends on several factors, some of the main ones are: perforation size, perforation density, the length of the target zone, and the density of the treating fluids.
Obviously, the effectiveness of ball sealers depends on the seating efficiency of these balls.
Ball sealers can be lighter (floater) or heavier (sinker) than the treating fluids.
The advantages and disadvantages of each type of ball sealers are discussed by Bilden et al.
1 Several research groups addressed methods and factors to enhance the performance of these balls.
2–4.

Related Results

Non-Recommended Publishing Lists: Strategies for Detecting Deceitful Journals
Non-Recommended Publishing Lists: Strategies for Detecting Deceitful Journals
Abstract The rapid growth of open access publishing (OAP) has significantly improved the accessibility and dissemination of scientific knowledge. However, this expansion has also c...
Evaluation of Hospital Laboratories Design in Ethiopia
Evaluation of Hospital Laboratories Design in Ethiopia
Background: Since advancement of science and technology in the area of laboratory medicine in 21st century the design of laboratory should be organized into high flexibility zones ...
Immune state networks of wild and laboratory mice
Immune state networks of wild and laboratory mice
AbstractThe mammalian immune system protects individuals from infection and disease. It is a complex system of interacting cells and molecules and extensive work, principally with ...
"Best Tradition": CREATE, JCSEE and the Program Evaluation Standards
"Best Tradition": CREATE, JCSEE and the Program Evaluation Standards
Background: Evaluation “is a task in the best tradition of the most abstract theoretical science as well as the most practical applied science” (Scriven, 1968, p .9). The Program E...
Measurable Progress? Teaching Artsworkers to Assess and Articulate the Impact of Their Work
Measurable Progress? Teaching Artsworkers to Assess and Articulate the Impact of Their Work
The National Cultural Policy Discussion Paper—drafted to assist the Australian Government in developing the first national Cultural Policy since Creative Nation nearly two decades ...
Laboratory Costs in the Context of Disease
Laboratory Costs in the Context of Disease
Abstract Background: To determine the contribution of laboratory costs to the overall costs of managing hospital patients with different diseases, we studied the cos...
The Future of Evaluation in Society
The Future of Evaluation in Society
The impetus for this volume lives in a rich and vibrant past. It is organized to honor one of the founders and most prolific contributors to the profession and transdiscipline of e...
MODEL EVALUASI PRAKTIKUM KIMIA DI LEMBAGA PENDIDIKAN TENAGA KEPENDIDIKAN
MODEL EVALUASI PRAKTIKUM KIMIA DI LEMBAGA PENDIDIKAN TENAGA KEPENDIDIKAN
Penelitian ini bertujuan untuk memperoleh model evaluasi program yang teruji, untuk mengevaluasi kualitas praktikum kimia. Pengembangan model evaluasi program terdiri atas empat va...

Back to Top