Javascript must be enabled to continue!
Detachable Aortic Clamp for Minimally Invasive Cardiac Surgery
View through CrossRef
Since its first implementation, minimally invasive cardiac surgery has become more and more popular among surgeons. By avoiding a complete opening of the sternum, this surgery is traditionally associated with a faster recovery, less surgical pain and less postoperative bleeding and transfusions. With its growing popularity, the need for specifically designed surgical instrumentation is evident. Since 2008, the detachable-branch Glauber clamp (Cardiovision-Trytech, Tokyo, Japan) has been used to facilitate aortic cross-clamp during minimally invasive cardiac surgery, to optimize the intraoperative visualization field without the need for adjunctive incisions of the thorax. It has been specifically developed for limited single-access minimally invasive valve surgery. The clamp is introduced through the main access incision (mini-sternotomy or mini thoracotomy) by means of a specifically designed delivery system, which is subsequently removed, leaving inside the thorax only the detachable closed branches on the aorta. Since its first implementation, the clamp has been used in numerous patients at several cardiac surgery centers worldwide. Over the years, attempts have been made to improve its ergonomics and enhance its performance. The G2 detachable-branch Glauber clamp (USB Medical, Hatboro, PA, USA) occupies a smaller space inside the thorax, has a simplified gripping mechanism and comes with detachable arms that enhance versatility with up to 10 possible clamp configurations. This article describes the characteristics of detachable-branch aortic clamps and compares them to other aortic cross-clamps that are currently available for minimally invasive cardiac surgery.
Surgical Technology Online
Title: Detachable Aortic Clamp for Minimally Invasive Cardiac Surgery
Description:
Since its first implementation, minimally invasive cardiac surgery has become more and more popular among surgeons.
By avoiding a complete opening of the sternum, this surgery is traditionally associated with a faster recovery, less surgical pain and less postoperative bleeding and transfusions.
With its growing popularity, the need for specifically designed surgical instrumentation is evident.
Since 2008, the detachable-branch Glauber clamp (Cardiovision-Trytech, Tokyo, Japan) has been used to facilitate aortic cross-clamp during minimally invasive cardiac surgery, to optimize the intraoperative visualization field without the need for adjunctive incisions of the thorax.
It has been specifically developed for limited single-access minimally invasive valve surgery.
The clamp is introduced through the main access incision (mini-sternotomy or mini thoracotomy) by means of a specifically designed delivery system, which is subsequently removed, leaving inside the thorax only the detachable closed branches on the aorta.
Since its first implementation, the clamp has been used in numerous patients at several cardiac surgery centers worldwide.
Over the years, attempts have been made to improve its ergonomics and enhance its performance.
The G2 detachable-branch Glauber clamp (USB Medical, Hatboro, PA, USA) occupies a smaller space inside the thorax, has a simplified gripping mechanism and comes with detachable arms that enhance versatility with up to 10 possible clamp configurations.
This article describes the characteristics of detachable-branch aortic clamps and compares them to other aortic cross-clamps that are currently available for minimally invasive cardiac surgery.
Related Results
ADVANCES AND CHALLENGES IN MINIMALLY INVASIVE SURGERY FOR THE TREATMENT OF HERNIAS
ADVANCES AND CHALLENGES IN MINIMALLY INVASIVE SURGERY FOR THE TREATMENT OF HERNIAS
Minimally invasive surgery has revolutionized the treatment of various medical conditions, offering significant benefits in terms of recovery and fewer complications. In the field ...
Blood pressure, hypertension, and the risk of aortic aneurysm in the UK Biobank
Blood pressure, hypertension, and the risk of aortic aneurysm in the UK Biobank
Abstract
Background
Although an association between elevated blood pressure and risk of aortic aneurysm is established, f...
P1820New parameters for the evaluation of mechanic and elastic properties of the aortic root in Marfan Syndrome
P1820New parameters for the evaluation of mechanic and elastic properties of the aortic root in Marfan Syndrome
Abstract
Background
Elastic properties of the thoracic aorta in patients with Marfan Syndrome (MS) have already been evaluated w...
Stapled Aortic Anastomoses: A Minimally Invasive, Feasible Alternative to Videoscopic Aortic Suturing?
Stapled Aortic Anastomoses: A Minimally Invasive, Feasible Alternative to Videoscopic Aortic Suturing?
Widespread applications of totally laparoscopic aortic reconstructions have been limited by the long cross-clamp time required to suture the aortic anastomosis despite improvement ...
063. ROBOTIC ASSISTED MIMINALLY INVASIVE IVOR-LEWIS ESOPHAGECTOMY VERSUS CONVENTIONAL MINIMALLY INVASIVE IVOR-LEWIS ESOPHAGECTOMY
063. ROBOTIC ASSISTED MIMINALLY INVASIVE IVOR-LEWIS ESOPHAGECTOMY VERSUS CONVENTIONAL MINIMALLY INVASIVE IVOR-LEWIS ESOPHAGECTOMY
Abstract
Background
Minimally invasive technique for esophagectomy has emerged as the standard of care for resectable esophageal...
AORTIC ROOT ANEURYSM OR ECTASIA TREATED WITH AORTIC ROOT WRAPPED PROCEDURE
AORTIC ROOT ANEURYSM OR ECTASIA TREATED WITH AORTIC ROOT WRAPPED PROCEDURE
Objectives
To develop a relatively simple and effective and less risk operation, aortic root wrapped procedure, to treat with aortic root aneurysm or ectasia.
...
Predictors of poor cardiac recovery pattern after aortic declamping in consecutive cardiac surgery cases
Predictors of poor cardiac recovery pattern after aortic declamping in consecutive cardiac surgery cases
Background Poor Cardiac recovery following aortic declamping in cardiac surgery is associated with increased morbidity and mortality. This study aims to identify the predictors of ...
P1716 Aorto-left atrial fistula with left atrium dissection
P1716 Aorto-left atrial fistula with left atrium dissection
Abstract