Javascript must be enabled to continue!
Mechanical Properties of Isolated Primary Cilia Measured by Micro-tensile Test and Atomic Force Microscopy
View through CrossRef
Mechanotransduction is a well-known mechanism by which cells sense their surrounding mechanical environment, convert mechanical stimuli into biochemical signals, and eventually change their morphology and functions. Primary cilia are believed to be mechanosensors existing on the surface of the cell membrane and support cells to sense surrounding mechanical signals. Knowing the mechanical properties of primary cilia is essential to understand their responses, such as sensitivity to mechanical stimuli. Previous studies have so far conducted flow experiments or optical trap techniques to measure the flexural rigidity EI (E: Young’s modulus, I: second moment of inertia) of primary cilia; however, the flexural rigidity is not a material property of materials and depends on mathematical models used in the determination, leading to a discrepancy between studies. For better characterization of primary cilia mechanics, Young’s modulus should be directly and precisely measured. In this study, the tensile Young’s modulus of isolated primary cilia is, for the first time, measured by using an in-house micro-tensile tester. The different strain rates of 0.01–0.3 s−1 were applied to isolated primary cilia, which showed a strain rate–dependent Young’s modulus in the range of 69.5–240.0 kPa on average. Atomic force microscopy was also performed to measure the local Young’s modulus of primary cilia, showing the Young’s modulus within the order of tens to hundreds of kPa. This study could directly provide the global and local Young’s moduli, which will benefit better understanding of primary cilia mechanics.
Title: Mechanical Properties of Isolated Primary Cilia Measured by Micro-tensile Test and Atomic Force Microscopy
Description:
Mechanotransduction is a well-known mechanism by which cells sense their surrounding mechanical environment, convert mechanical stimuli into biochemical signals, and eventually change their morphology and functions.
Primary cilia are believed to be mechanosensors existing on the surface of the cell membrane and support cells to sense surrounding mechanical signals.
Knowing the mechanical properties of primary cilia is essential to understand their responses, such as sensitivity to mechanical stimuli.
Previous studies have so far conducted flow experiments or optical trap techniques to measure the flexural rigidity EI (E: Young’s modulus, I: second moment of inertia) of primary cilia; however, the flexural rigidity is not a material property of materials and depends on mathematical models used in the determination, leading to a discrepancy between studies.
For better characterization of primary cilia mechanics, Young’s modulus should be directly and precisely measured.
In this study, the tensile Young’s modulus of isolated primary cilia is, for the first time, measured by using an in-house micro-tensile tester.
The different strain rates of 0.
01–0.
3 s−1 were applied to isolated primary cilia, which showed a strain rate–dependent Young’s modulus in the range of 69.
5–240.
0 kPa on average.
Atomic force microscopy was also performed to measure the local Young’s modulus of primary cilia, showing the Young’s modulus within the order of tens to hundreds of kPa.
This study could directly provide the global and local Young’s moduli, which will benefit better understanding of primary cilia mechanics.
Related Results
Electrostatic Artificial Cilia
Electrostatic Artificial Cilia
In lab‐on‐chip devices, on which complete (bio‐)chemical analysis laboratories are miniaturized and integrated, it is essential to manipulate fluids in sub‐millimetre channels and ...
Light‐actuated Artificial Cilia Based on Liquid Crystal Networks
Light‐actuated Artificial Cilia Based on Liquid Crystal Networks
The use of liquid crystal networks (LCNs) for trigger‐driven cilia combines control over the deformation direction with a large work potential. Photopolymerization of mesogenic mon...
Mutation of Polaris, an Intraflagellar Transport Protein, Shortens Neuronal Cilia
Mutation of Polaris, an Intraflagellar Transport Protein, Shortens Neuronal Cilia
Primary cilia are non-motile organelles having 9+0 microtubules that project from the basal body of the cell. While the main purpose of motile cilia in mammalian cells is to move f...
Introduction
Introduction
This book is about artificial cilia. The use of artificial cilia to create pumping and/or mixing in micro‐fluidic devices is a recent development, inspired by nature. Cilia are sma...
I Like to Move It, Move It: The Role of Kif3B of Kinesin II in Primary Cilia Cilia
I Like to Move It, Move It: The Role of Kif3B of Kinesin II in Primary Cilia Cilia
Primary cilia are structures found on the surface of most cells and are important for cell signaling. For cilia to develop and function properly, materials must be transported in a...
Atomic electron tomography: 3D structures without crystals
Atomic electron tomography: 3D structures without crystals
BACKGROUND
To understand material properties and functionality at the most fundamental level, one must know the three-dimensional (3D) positions of atoms with high prec...
Micromechanical characterization of small volumes by means of nanoindentation
Micromechanical characterization of small volumes by means of nanoindentation
Mechanical characterization of micro-volume systems, as thin films or micro-sized phases embedded in multiphase materials, has attracted special interest in the last decades since...
Tubulin glycylation controls primary cilia length
Tubulin glycylation controls primary cilia length
As essential components of the eukaryotic cytoskeleton, microtubules fulfill a variety of functions that can be temporally and spatially controlled by tubulin posttranslational mod...

