Javascript must be enabled to continue!
GW24-e0454 To evaluate acute myocardial ischaemia in by 11C-N-CH3-Dopamine PET/CT imaging
View through CrossRef
Objectives
To evaluate acute myocardial ischaemia using 11C-N-CH3- Dopamine which is cardiac sympathetic nerve molecular probe compared with 13NH3H2O myocardial perfusion.
Methods
Bama miniature pigs (n = 12, 6 male, 6 female, 1-1.5 y old, 30 kg-40 kg, provided by the Animal Research Institute of Northeast Agricultural University of China) were used in this study. AMI model were made by ligating the blood stream of 1/3 of descending branch of left coronary artery (LAD) in pigs for ligating 30 minutes and releasing. 11C-N-CH3-dopamine and 13NH3H2O PET/CT imaging were performed in pigs before moulding and after the success of modelling first week and first, third and sixth months.
Results
(1) The areas of radioactive sparseness and defect in 11C-N-CH3-dopamine imaging were larger than similar with stress 13NH3H2O myocardial perfusion imaging in 12 pigs after the success of modelling first week. (2) The areas of radioactive sparseness and defect in 11C-N-CH3-dopamine imaging were more than stress 13NH3H2O myocardial perfusion imaging in 12 pigs after the success of modelling first and third months. And the areas of radioactive sparseness and defect in 11C-N-CH3-dopamine imaging after the success of modelling were gradually expanded over time from first week to third months. (3)The areas of radioactive sparseness and defect in 11C-N-CH3-dopamine imaging after the success of modelling were gradually shrinked over time from third months to sixth months.
Conclusions
11C-N-CH3-dopamine was more sensitive diagnosis method for myocardial ischaemia compared with 13NH3H2O myocardial perfusion imaging and range and degree of cardiac nerve injury more than perfusion and recovery slowly under ischaemic condition.
Title: GW24-e0454 To evaluate acute myocardial ischaemia in by 11C-N-CH3-Dopamine PET/CT imaging
Description:
Objectives
To evaluate acute myocardial ischaemia using 11C-N-CH3- Dopamine which is cardiac sympathetic nerve molecular probe compared with 13NH3H2O myocardial perfusion.
Methods
Bama miniature pigs (n = 12, 6 male, 6 female, 1-1.
5 y old, 30 kg-40 kg, provided by the Animal Research Institute of Northeast Agricultural University of China) were used in this study.
AMI model were made by ligating the blood stream of 1/3 of descending branch of left coronary artery (LAD) in pigs for ligating 30 minutes and releasing.
11C-N-CH3-dopamine and 13NH3H2O PET/CT imaging were performed in pigs before moulding and after the success of modelling first week and first, third and sixth months.
Results
(1) The areas of radioactive sparseness and defect in 11C-N-CH3-dopamine imaging were larger than similar with stress 13NH3H2O myocardial perfusion imaging in 12 pigs after the success of modelling first week.
(2) The areas of radioactive sparseness and defect in 11C-N-CH3-dopamine imaging were more than stress 13NH3H2O myocardial perfusion imaging in 12 pigs after the success of modelling first and third months.
And the areas of radioactive sparseness and defect in 11C-N-CH3-dopamine imaging after the success of modelling were gradually expanded over time from first week to third months.
(3)The areas of radioactive sparseness and defect in 11C-N-CH3-dopamine imaging after the success of modelling were gradually shrinked over time from third months to sixth months.
Conclusions
11C-N-CH3-dopamine was more sensitive diagnosis method for myocardial ischaemia compared with 13NH3H2O myocardial perfusion imaging and range and degree of cardiac nerve injury more than perfusion and recovery slowly under ischaemic condition.
Related Results
In-target Production of [11C]CH4 from a Nitrogen/Hydrogen Gas Target as a Function of Beam Current, Irradiation Time, and Target Temperature
In-target Production of [11C]CH4 from a Nitrogen/Hydrogen Gas Target as a Function of Beam Current, Irradiation Time, and Target Temperature
Abstract
Background
Production of [11C]CH4 from gas targets is notorious for weak performance with respect to yield, especially when using high beam currents. However, air...
Abstract 1646: Synthesis of [11C]onapristone for clinical investigation
Abstract 1646: Synthesis of [11C]onapristone for clinical investigation
Abstract
Background: Onapristone is a type I anti-progestin, which prevents the progesterone receptor (PR) monomers from dimerizing, inhibits ligand-induced phosphor...
SEMANA DE ENFERMAGEM E SEUS ASPECTOS SOCIAIS NA VALORIZAÇÃO PROFISSIONAL: UM RELATO DE EXPERIÊNCIA DO GRUPO PET-ENFERMAGEM
SEMANA DE ENFERMAGEM E SEUS ASPECTOS SOCIAIS NA VALORIZAÇÃO PROFISSIONAL: UM RELATO DE EXPERIÊNCIA DO GRUPO PET-ENFERMAGEM
A enfermagem é o pilar da assistência pois está na linha de frente do cuidado holístico, todavia esta é estigmatizada e desvalorizada, assim como não possui reconhecimento consider...
In-target production of [11C]CH4 from a nitrogen/hydrogen gas target as a function of beam current, irradiation time, and target temperature
In-target production of [11C]CH4 from a nitrogen/hydrogen gas target as a function of beam current, irradiation time, and target temperature
Abstract
Background
Production of [11C]CH4 from gas targets is notorious for weak performance with respect to yield, especially when using high beam...
Application of 11C-CHO in the imaging of cerebral alveolar echinococcosis: A prospective study
Application of 11C-CHO in the imaging of cerebral alveolar echinococcosis: A prospective study
11C-acetylcholine (11C-CHO) is a positron emission tomography (PET) radiotracer that has been utilized in the diagnosis and treatment of prostate, esophageal, and lung cancers. Thi...
Characteristics and influencing factors of 11C-CFT PET imaging in patients with early and late onset Parkinson’s disease
Characteristics and influencing factors of 11C-CFT PET imaging in patients with early and late onset Parkinson’s disease
ObjectiveThis study aims to explore the difference between 11C-methyl-N-2β-carbomethoxy-3β-(4-fluorophenyl)-tropanel (11C-CFT) positron emission tomography (PET) imaging in the ear...
Outcome Prediction by Myocardial External Efficiency from 11C-Acetate Positron Emission Tomography in Cardiac Amyloidosis
Outcome Prediction by Myocardial External Efficiency from 11C-Acetate Positron Emission Tomography in Cardiac Amyloidosis
Abstract
Aims
This study aimed to study the prognostic value of myocardial oxygen consumption (MVO2) and myocardial exter...
N‐Disilanyl‐phosphinimide
N‐Disilanyl‐phosphinimide
AbstractAus (CH3)3P = NLi und (CH3)5Si2Cl bzw. (CH3)4Si2Cl2 sind die disilanyl‐substituierten Phosphinimide (CH3)3P = N–Si2(CH3)5 (1), [(CH3)3P = N–Si(CH3)2–]2 (2) und (CH3)3P = N–...