Transrectal ultrasonography: why are estimates of prostate volume and dimension so inaccurate?
View through CrossRef
Objectives
To determine why there are variations in the volumes of the prostate obtained by step planimetry and those calculated from the prolate ellipsoid formula using the measured maximum gland dimensions, to assess the reproducibility of estimates of prostate volume from transrectal ultrasonography (TRUS) and to determine the effect of the angle of the transrectal probe, the human error in the clinical setting and the benefit of computer enhancement of the ultrasonograms.
Patients and methods
Forty‐five men (mean age 72 years, range 43–89) with symptoms of prostatic enlargement were divided randomly into three groups; those in group 1 had their prostate volume estimated three times by measuring the maximal gland dimensions and calculating the volume using the prolate ellipsoid formula (dimensional method) and by step planimetry, to assess the reproducibility of TRUS; men in group 2 had their prostate volume estimated using the dimensional method and by step planimetry with the probe in the optimal axis, and then from scans repeated after deflecting the transrectal probe 5° anteriorly and posteriorly; men in group 3 had their prostate volume estimated once by the dimensional method and by step planimetry. Step planimetry was carried out using a specially designed indexer firmly attached to the examination couch. All ‘frozen’ images and planimetry slices were videotaped for later computer enhancement. The volumes and dimensions obtained by each method were compared.
Results
The volumes obtained by step planimetry were 17% greater than those obtained by the dimensional method because the craniocaudal, anteroposterior and transverse diameters were underestimated significantly by the latter (by 13%, 2% and 7%, respectively). The largest anteroposterior and transverse diameters were included in the same axial scan in only 44%, while the largest craniocaudal diameter was in the midline in only 38%, of the patients. The human error in the clinic was negligible (2%) with a good correlation between the dimensions and volumes obtained in the clinic and those from computer‐enhanced images (
r
=0.94). There were no advantages in computer enhancing the TRUS images. Volumes calculated from the dimensional method using the maximum dimensions obtained from planimetric contours correlated well with planimetric volumes (
r
=0.93). The reproducibility of TRUS showed a mean error of 8% by the dimensional method and 1% by step planimetry. Anterior deflection of the transrectal probe reduced the estimated volume by 2% and posterior deflection increased the volume by 4%, using the dimensional method, while there were no significant volume changes when estimated by step planimetry.
Conclusion
This study confirms that to estimate accurately the volume of the prostate using the prolate ellipsoid formula, the current methodology needs to be changed. The largest anteroposterior and transverse diameters may need to be measured in different transverse scan slices and the largest craniocaudal diameter in a sagittal scan away from the midline. If volume estimation is to be repeated then step planimetry is reliable and TRUS using the prolate ellipsoid formula is not.
Title: Transrectal ultrasonography: why are estimates of prostate volume and dimension so inaccurate?
Description:
Objectives
To determine why there are variations in the volumes of the prostate obtained by step planimetry and those calculated from the prolate ellipsoid formula using the measured maximum gland dimensions, to assess the reproducibility of estimates of prostate volume from transrectal ultrasonography (TRUS) and to determine the effect of the angle of the transrectal probe, the human error in the clinical setting and the benefit of computer enhancement of the ultrasonograms.
Patients and methods
Forty‐five men (mean age 72 years, range 43–89) with symptoms of prostatic enlargement were divided randomly into three groups; those in group 1 had their prostate volume estimated three times by measuring the maximal gland dimensions and calculating the volume using the prolate ellipsoid formula (dimensional method) and by step planimetry, to assess the reproducibility of TRUS; men in group 2 had their prostate volume estimated using the dimensional method and by step planimetry with the probe in the optimal axis, and then from scans repeated after deflecting the transrectal probe 5° anteriorly and posteriorly; men in group 3 had their prostate volume estimated once by the dimensional method and by step planimetry.
Step planimetry was carried out using a specially designed indexer firmly attached to the examination couch.
All ‘frozen’ images and planimetry slices were videotaped for later computer enhancement.
The volumes and dimensions obtained by each method were compared.
Results
The volumes obtained by step planimetry were 17% greater than those obtained by the dimensional method because the craniocaudal, anteroposterior and transverse diameters were underestimated significantly by the latter (by 13%, 2% and 7%, respectively).
The largest anteroposterior and transverse diameters were included in the same axial scan in only 44%, while the largest craniocaudal diameter was in the midline in only 38%, of the patients.
The human error in the clinic was negligible (2%) with a good correlation between the dimensions and volumes obtained in the clinic and those from computer‐enhanced images (
r
=0.
94).
There were no advantages in computer enhancing the TRUS images.
Volumes calculated from the dimensional method using the maximum dimensions obtained from planimetric contours correlated well with planimetric volumes (
r
=0.
93).
The reproducibility of TRUS showed a mean error of 8% by the dimensional method and 1% by step planimetry.
Anterior deflection of the transrectal probe reduced the estimated volume by 2% and posterior deflection increased the volume by 4%, using the dimensional method, while there were no significant volume changes when estimated by step planimetry.
Conclusion
This study confirms that to estimate accurately the volume of the prostate using the prolate ellipsoid formula, the current methodology needs to be changed.
The largest anteroposterior and transverse diameters may need to be measured in different transverse scan slices and the largest craniocaudal diameter in a sagittal scan away from the midline.
If volume estimation is to be repeated then step planimetry is reliable and TRUS using the prolate ellipsoid formula is not.
Related Results
Holmium laser enucleation of the prostate versus bipolar transurethral enucleation of the prostate in management of benign prostatic hyperplasia: A randomized controlled trial
Holmium laser enucleation of the prostate versus bipolar transurethral enucleation of the prostate in management of benign prostatic hyperplasia: A randomized controlled trial
Objective
To evaluate the safety, efficacy and cost‐effectiveness of holmium enucleation of the prostate and bipolar transurethral enucleation of the prostate.
...
Abstract 5758: Deletions of olfactomedin 4 gene is associated with progression of prostate cancer
Abstract 5758: Deletions of olfactomedin 4 gene is associated with progression of prostate cancer
Abstract
The human olfactomedin 4 gene (OLFM4) encodes an olfactomedin-related glycoprotein, which our group first cloned and characterized in myeloid cells and mapp...
Abstract 4602: Clinicopathological and genetic features of prostate cancer in Algerian patients: First report
Abstract 4602: Clinicopathological and genetic features of prostate cancer in Algerian patients: First report
Abstract
Background: Prostate cancer is the second most frequent malignancy (after lung cancer) in men worldwide. It is the third most common cancer in men in Algeri...
Analysis of the spatial distribution and clinical features of prostate cancer in transperineal prostate biopsy
Analysis of the spatial distribution and clinical features of prostate cancer in transperineal prostate biopsy
Abstract
Background Recently, most studies on the spatial distribution of the prostate cancer are based on the samples confirmed by transrectal prostate biopsy (TRBx), whic...
The 20-core prostate biopsy as an initial strategy: impact on the detection of prostatic cancer
The 20-core prostate biopsy as an initial strategy: impact on the detection of prostatic cancer
Introduction: To increase the detection rate of prostate cancer inrecent years, we examined the increase in the number of corestaken at initial prostate biopsy. We hypothesized tha...
Diagnostic Accuracy of Prostatic Specific Antigen Densityin Different Prostatic Disorders
Diagnostic Accuracy of Prostatic Specific Antigen Densityin Different Prostatic Disorders
Objective: To determine the diagnostic accuracy of PSA density in Prostate Cancer, Benign Prostatic Hyperplasia (BPH) and Prostatitis, taking biopsy as the gold standard.
Stu...
Study on Early Prostate Cancer Antigen (EPCA) and existent risk factors of prostate cancer, Sudan: A case-control study
Study on Early Prostate Cancer Antigen (EPCA) and existent risk factors of prostate cancer, Sudan: A case-control study
Background: Early prostate cancer antigen (EPCA), a nuclear matrix protein, has recently been recommended as a hopeful biomarker for early prostate carcinogenesis. Objectives: To e...
Abstract 1568: The role of CCL2 CCL17 CCL22-CCR4 axis in prostate cancer metastasis
Abstract 1568: The role of CCL2 CCL17 CCL22-CCR4 axis in prostate cancer metastasis
Abstract
BACKGROUND: Multiple steps and factors are involved in prostate carcinogenesis and tumor progression. The early studies have found that tumor-associated mac...