Daylighting Metrics: an Approach to Dynamic Cubic Illuminance

View through CrossRef
Advances in research work in the field of numerical analysis of daylight performance have generated in-depth knowledge on photometric measurements of daylight quality. Most dynamic metrics are based on illuminance, which is a two-dimensional concept insofar as it is concerned with the density of luminous flux incident at a point on a surface. In order to extend dynamic metrics into the third dimension and consider the distribution of illumination at a point in space, it is important to generate new advances in simulation environments and consider spatial illumination metrics. In this context, the main objective of the present work was to advance in the development of cubic dynamic daylight metrics, as a complement to the two dimensional analysis currently employed, promoting the use of Climate Based Daylight Modelling (CBDM). For this purpose, cylindrical to horizontal illuminance ratio is applied to dynamic simulation paradigm developing the concept of useful modeling indexs (UMIs). The research methodology applied in this work is divided into two main parts: (i) two dimensional concept: spatial daylight autonomy (sDA(300lx,50%) -horizontal-, sDA(175lx,50%) -vertical-) and uniformity, and (ii) three dimensional concept: useful cylindrical to horizontal illuminance ratio (uEcl/Eh(0.3-0.6)). In order to assess this method, two spaces (RR1 and RR2) of the Lavalle Public Library, located in Mendoza-Argentina, were taken as a case study. Results show important differences in horizontal illuminance between RR1 and RR2 (∆sDA(300lx, 50%) > 80%). Similar values of uEcl/Ewp(0.3-0.6) -useful cylindrical to horizontal illuminance ratio- are detected in both rooms (RR1= 69.32 % and RR2= 72.24 %) in nodes near north opening. Yet there are significant differences (< 36%) of uEcl/Ewp(0.3-0.6) between nodes located near the south wall, this is due to the obstruction of a south opening in RR2. Furthermore, it is important to mention that 2D metrics display a more uniform behavior than 3D metrics. This shows itself clearly if we take into account that difference in sDA are much lower than difference in uEcl/Eh(0.3-0.6), if we compare nodes closest to the north windows to does that are far from it, in both rooms (RR1 and RR2). This results from the fact that cubic metrics are more sensitive to the direction of light. This is of crucial importance for daylight studies in clear sky condition, due to the defined direction of direct solar radiation. Finally, a new approach to daylighting performance analysis based on the addition of cubic metrics to dynamic daylight paradigm is proposed: useful modelling indexs (UMIs). UMIs make it possible to quantify annual occurrence of proper light modelling conditions. As an initial approach, cylindrical to horizontal illuminance ratio (Ecl/Ewp(0.3-0.6)) has been considered, due to its current use in international standards.
Title: Daylighting Metrics: an Approach to Dynamic Cubic Illuminance
Description:
Advances in research work in the field of numerical analysis of daylight performance have generated in-depth knowledge on photometric measurements of daylight quality.
Most dynamic metrics are based on illuminance, which is a two-dimensional concept insofar as it is concerned with the density of luminous flux incident at a point on a surface.
In order to extend dynamic metrics into the third dimension and consider the distribution of illumination at a point in space, it is important to generate new advances in simulation environments and consider spatial illumination metrics.
In this context, the main objective of the present work was to advance in the development of cubic dynamic daylight metrics, as a complement to the two dimensional analysis currently employed, promoting the use of Climate Based Daylight Modelling (CBDM).
For this purpose, cylindrical to horizontal illuminance ratio is applied to dynamic simulation paradigm developing the concept of useful modeling indexs (UMIs).
The research methodology applied in this work is divided into two main parts: (i) two dimensional concept: spatial daylight autonomy (sDA(300lx,50%) -horizontal-, sDA(175lx,50%) -vertical-) and uniformity, and (ii) three dimensional concept: useful cylindrical to horizontal illuminance ratio (uEcl/Eh(0.
3-0.
6)).
In order to assess this method, two spaces (RR1 and RR2) of the Lavalle Public Library, located in Mendoza-Argentina, were taken as a case study.
Results show important differences in horizontal illuminance between RR1 and RR2 (∆sDA(300lx, 50%) > 80%).
Similar values of uEcl/Ewp(0.
3-0.
6) -useful cylindrical to horizontal illuminance ratio- are detected in both rooms (RR1= 69.
32 % and RR2= 72.
24 %) in nodes near north opening.
Yet there are significant differences (< 36%) of uEcl/Ewp(0.
3-0.
6) between nodes located near the south wall, this is due to the obstruction of a south opening in RR2.
Furthermore, it is important to mention that 2D metrics display a more uniform behavior than 3D metrics.
This shows itself clearly if we take into account that difference in sDA are much lower than difference in uEcl/Eh(0.
3-0.
6), if we compare nodes closest to the north windows to does that are far from it, in both rooms (RR1 and RR2).
This results from the fact that cubic metrics are more sensitive to the direction of light.
This is of crucial importance for daylight studies in clear sky condition, due to the defined direction of direct solar radiation.
Finally, a new approach to daylighting performance analysis based on the addition of cubic metrics to dynamic daylight paradigm is proposed: useful modelling indexs (UMIs).
UMIs make it possible to quantify annual occurrence of proper light modelling conditions.
As an initial approach, cylindrical to horizontal illuminance ratio (Ecl/Ewp(0.
3-0.
6)) has been considered, due to its current use in international standards.

Related Results

Cumulative Frequency Distributions for Daily Global Illuminance
Cumulative Frequency Distributions for Daily Global Illuminance
The present article describes the development of cumulative frequency distributions (similar to clearness index distributions) for daily global horizontal illuminance based on the ...
Fade Lighting Control Method for Visual Comfort and Energy Saving
Fade Lighting Control Method for Visual Comfort and Energy Saving
This study proposes a fade lighting control method to ensure the visual comfort of indoor occupants through gradual illuminance control while saving energy. The illuminance sensor ...
Harvesting Solar Energy for Green Buildings Through Plastic Optical-Fibre Daylighting Systems: A Systematic Review and Meta-Analysis
Harvesting Solar Energy for Green Buildings Through Plastic Optical-Fibre Daylighting Systems: A Systematic Review and Meta-Analysis
Optical-fibre daylighting systems (OFDS) harvest solar energy as a renewable lighting resource by delivering sunlight deep into green buildings. This emerging technology for sustai...
Prediction of Annual Daylighting Performance Using Inverse Models
Prediction of Annual Daylighting Performance Using Inverse Models
This paper presents the results of a study that developed improved inverse models to accurately predict the annual daylighting performance (sDA and lighting energy use) of various ...
Development of a Light Duct Using Relay Lenses and Diffusers
Development of a Light Duct Using Relay Lenses and Diffusers
Due to the recent increase in building energy consumption, daylighting technologies such as light ducts are becoming increasingly important. However, conventional light ducts have ...
Aspiring Scientific Design: Hannes Meyer and Hans Wittwer’s Petersschule Project and Daylighting Scholarship
Aspiring Scientific Design: Hannes Meyer and Hans Wittwer’s Petersschule Project and Daylighting Scholarship
This paper looks at the advancement and implementation of daylighting calculations in architectural design during High Modernism. Particularly, it analyzes the engineering and arch...
Smart Daylighting Strategies for Architectural Studios: Evaluating Louvre Angles and Time Effects Through Revit Simulations
Smart Daylighting Strategies for Architectural Studios: Evaluating Louvre Angles and Time Effects Through Revit Simulations
This study explores the effectiveness of louvre windows in optimizing daylighting within an architectural studio using Revit simulations. The aim was to enhance natural light distr...
PARAMETRIC OF DAYLIGHT PERFORMANCE THROUGH FACADE ENVELOPE RATIO OF HIGH-RISE OFFICE BUILDING IN TROPICAL CLIMATES
PARAMETRIC OF DAYLIGHT PERFORMANCE THROUGH FACADE ENVELOPE RATIO OF HIGH-RISE OFFICE BUILDING IN TROPICAL CLIMATES
In tropical climates, facade design plays a crucial role in balancing daylighting performance and thermal control to enhance energy efficiency and occupant comfort. This study inve...

Back to Top