Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Potential Application of 4D Technology in Fabrication of Orthodontic Aligners

View through CrossRef
Objectives: To investigate and quantify forces generated by three-dimensional-printed aligners made of shape memory polymers (four-dimensional [4D] aligner).Methods: Clear X v1.1 material was used in this study. On a custom-made typodont model, correction of maxillary central incisor (tooth 21) malposition by 4D aligners with thicknesses of 0.8 and 1.0 mm was measured by superimposition of subsequent scans. Maximum deflection forces generated by foil sheet specimens were measured at different temperatures in three-point bending (3-PB) tests. In a biomechanical system (orthodontic measurement and simulation system [OMSS]), forces generated on movements of tooth 21 by the 4D aligners were measured at different temperatures.Results: 4D aligners succeeded to achieve a significant tooth movement (2.5 ± 0.5 mm) on the typodont, with insignificant difference between different thicknesses. In the 3-PB test, the maximum deflection forces measured at 20, 30, 37, 45, and 55°C, were 3.8 ± 1.1, 2.5 ± 0.9, 1.7 ± 0.6, 1.0 ± 0.4, and 0.5 ± 0.4 N, respectively. Forces delivered on palatal displacement of tooth 21 at 37, 45, and 55°C by 0.8-mm aligners were 0.3 ± 0.1, 0.2 ± 0.1, and 0.7 ± 0.2 N, respectively, whereas those by 1.0-mm aligners were 0.3 ± 0.1, 0.3 ± 0.1, and 0.6 ± 0.2 N, respectively. A good concordance with movement on the typodont model was shown in OMSS.Conclusion: An initial study of 4D-printed aligner shows its ability to move a tooth by biocompatible orthodontic forces, after a suitable thermal stimulus within the oral temperature range.
Title: Potential Application of 4D Technology in Fabrication of Orthodontic Aligners
Description:
Objectives: To investigate and quantify forces generated by three-dimensional-printed aligners made of shape memory polymers (four-dimensional [4D] aligner).
Methods: Clear X v1.
1 material was used in this study.
On a custom-made typodont model, correction of maxillary central incisor (tooth 21) malposition by 4D aligners with thicknesses of 0.
8 and 1.
0 mm was measured by superimposition of subsequent scans.
Maximum deflection forces generated by foil sheet specimens were measured at different temperatures in three-point bending (3-PB) tests.
In a biomechanical system (orthodontic measurement and simulation system [OMSS]), forces generated on movements of tooth 21 by the 4D aligners were measured at different temperatures.
Results: 4D aligners succeeded to achieve a significant tooth movement (2.
5 ± 0.
5 mm) on the typodont, with insignificant difference between different thicknesses.
In the 3-PB test, the maximum deflection forces measured at 20, 30, 37, 45, and 55°C, were 3.
8 ± 1.
1, 2.
5 ± 0.
9, 1.
7 ± 0.
6, 1.
0 ± 0.
4, and 0.
5 ± 0.
4 N, respectively.
Forces delivered on palatal displacement of tooth 21 at 37, 45, and 55°C by 0.
8-mm aligners were 0.
3 ± 0.
1, 0.
2 ± 0.
1, and 0.
7 ± 0.
2 N, respectively, whereas those by 1.
0-mm aligners were 0.
3 ± 0.
1, 0.
3 ± 0.
1, and 0.
6 ± 0.
2 N, respectively.
A good concordance with movement on the typodont model was shown in OMSS.
Conclusion: An initial study of 4D-printed aligner shows its ability to move a tooth by biocompatible orthodontic forces, after a suitable thermal stimulus within the oral temperature range.

Related Results

Comparison of Optical Properties of Clear Aligners Before and After In-vivo Aging
Comparison of Optical Properties of Clear Aligners Before and After In-vivo Aging
Introduction: There is a rising demand for clear aligners among orthodontic patients and after the expiry of Invisalign patent many indigenous aligners have been introduced in seve...
Physical and chemical changes of clear aligners after thermoforming and intraoral exposure
Physical and chemical changes of clear aligners after thermoforming and intraoral exposure
Objectives: This study assessed the physical and chemical changes of clear aligners after thermoforming and intraoral exposure. Material and Methods: This ex vivo study evaluated...
Aligners: General Characteristics, Advantages, and Disadvantages (Review)
Aligners: General Characteristics, Advantages, and Disadvantages (Review)
Abstract. In the past decade, removable orthodontic thermoplastic appliances—aligners—have become a widespread alternative to traditional fixed systems and orthodontic devices desi...
Assessing the Pros and Cons of Performing Orthognathic Surgery in Patients Undergoing Orthodontic Aligner Treatment
Assessing the Pros and Cons of Performing Orthognathic Surgery in Patients Undergoing Orthodontic Aligner Treatment
Objective: Orthodontic aligners have become one of the most requested treatments by patients. This study evaluated maxillofacial surgeons´ experience of using orthodontic aligners ...
Periodontal Implications of Orthodontic Treatment: Assessment of The Balance between Tooth Movement and Surrounding Tissue
Periodontal Implications of Orthodontic Treatment: Assessment of The Balance between Tooth Movement and Surrounding Tissue
Orthodontic treatment also aims to maintain ideal periodontal health. Gingival/periodontal conditions and orthodontic interventions have a complicated relationship because orthodon...
Effect of Varying Thickness of Clear Aligners in Orthodontic Therapy - A Review
Effect of Varying Thickness of Clear Aligners in Orthodontic Therapy - A Review
Clear aligner therapy (CAT) is one of the most rapidly expanding fields of orthodontics, propelled by patient interest in appliances that are aesthetic and removable. From the laun...

Back to Top