Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

A Novel VSG with Adaptive Virtual Inertia and Adaptive Damping Coefficient to Improve Transient Frequency Response of Microgrids

View through CrossRef
This paper proposes a combined adaptive virtual Inertia and adaptive damping control of a virtual synchronous generator (AID-VSG) to improve the dynamic frequency response of microgrids. In the proposed control scheme, the VSG’s virtual inertia and damping coefficients adapt themselves during the transients to, respectively, reduce frequency deviations and increase the oscillations’ damping. In addition, as an important feature, the proposed AID-VSG is suitable for distributed control scheme applications and is designed to not rely on phase-locked loop (PLL) measurements, which avoids PLL stability issues on weak grids. The control parameters of the proposed AID-VSG are tuned by the particle swarm optimization (PSO) algorithm to minimize the overshoot and settling time of the microgrid’s frequency during an islanding event. The AID-VSG is validated by a comparative analysis with three existing VSG control schemes, also tuned by the stated optimization algorithm. The performance of each compared VSG strategy is evaluated through the simulation of a set of 10,000 initial conditions, using the islanded microgrid’s nonlinear model. The best response among the VSG strategies was achieved by the proposed AID-VSG control for both the optimization problem and the set of initial conditions’ simulations.
Title: A Novel VSG with Adaptive Virtual Inertia and Adaptive Damping Coefficient to Improve Transient Frequency Response of Microgrids
Description:
This paper proposes a combined adaptive virtual Inertia and adaptive damping control of a virtual synchronous generator (AID-VSG) to improve the dynamic frequency response of microgrids.
In the proposed control scheme, the VSG’s virtual inertia and damping coefficients adapt themselves during the transients to, respectively, reduce frequency deviations and increase the oscillations’ damping.
In addition, as an important feature, the proposed AID-VSG is suitable for distributed control scheme applications and is designed to not rely on phase-locked loop (PLL) measurements, which avoids PLL stability issues on weak grids.
The control parameters of the proposed AID-VSG are tuned by the particle swarm optimization (PSO) algorithm to minimize the overshoot and settling time of the microgrid’s frequency during an islanding event.
The AID-VSG is validated by a comparative analysis with three existing VSG control schemes, also tuned by the stated optimization algorithm.
The performance of each compared VSG strategy is evaluated through the simulation of a set of 10,000 initial conditions, using the islanded microgrid’s nonlinear model.
The best response among the VSG strategies was achieved by the proposed AID-VSG control for both the optimization problem and the set of initial conditions’ simulations.

Related Results

Damping Of Moored Floating Structures
Damping Of Moored Floating Structures
1.ABSTRACT The resonant response of moored floating structures due to low-frequency excitation is controlled primarily by the effective damping coefficient of the...
Vertical sleeve gastrectomy improves liver and hypothalamic functions in obese mice
Vertical sleeve gastrectomy improves liver and hypothalamic functions in obese mice
Vertical sleeve gastrectomy (VSG) is an effective surgery to treat obesity and diabetes. However, the direct effect of VSG on metabolic functions is not fully understood. We aimed ...
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Objective: To determine the frequency of common chromosomal aberrations in local population idiopathic determine the frequency of common chromosomal aberrations in local population...
Effect of DFIG control parameters on small signal stability in power systems
Effect of DFIG control parameters on small signal stability in power systems
Abstract The doubly-fed induction generator (DFIG) with virtual inertia control and reactive damping control gives a renewable energy generation system inertia and damping ...
Effect of DFIG control parameters on small signal stability in power systems
Effect of DFIG control parameters on small signal stability in power systems
Abstract The doubly-fed induction generator (DFIG) with virtual inertia control and reactive damping control gives a renewable energy generation system inertia an...
Enhanced control strategies of VSG for EV charging station under a low inertia microgrid
Enhanced control strategies of VSG for EV charging station under a low inertia microgrid
The droop control strategies can realise an autonomous power allocation among virtual synchronous generators (VSGs) that can provide the recompenses of reduced system complexity an...
Prediction Of The Damping Controlled Response Of Offshore Structures To Random Excitation
Prediction Of The Damping Controlled Response Of Offshore Structures To Random Excitation
ABSTRACT A method is presented for predicting the damping controlled response of a structure at a known natural frequency to random wave forces. The results are a...

Back to Top