Javascript must be enabled to continue!
Bilateral comparison of 1 Ω and 10 kΩ standards (ongoing BIPM key comparisons BIPM.EM-K13.a and 13.b) between the NSAI NML (Ireland) and the BIPM
View through CrossRef
This report gives the result of a bilateral comparison of resistance between the NSAI NML (Ireland) and the BIPM carried out in 2014-2015. Two 1 Ω and two 10 kΩ travelling standards belonging to the BIPM were used. The comparison was carried out with an 'A-B-A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the NSAI-NML, and finally again at the BIPM. The measurand was the 4 terminal dc resistance at low power. The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparisons BIPM.EM-K13.a (for 1 Ω) and BIPM.EM-K13b (for 10 kΩ).
The results from the NSAI NML and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainties (95% confidence, k = 2) of 0.16 × 10-6 for 1 Ω and 0.42 × 10-6 for 10 kΩ.
Main text
To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.
The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Title: Bilateral comparison of 1 Ω and 10 kΩ standards (ongoing BIPM key comparisons BIPM.EM-K13.a and 13.b) between the NSAI NML (Ireland) and the BIPM
Description:
This report gives the result of a bilateral comparison of resistance between the NSAI NML (Ireland) and the BIPM carried out in 2014-2015.
Two 1 Ω and two 10 kΩ travelling standards belonging to the BIPM were used.
The comparison was carried out with an 'A-B-A' pattern of measurements; the standards were measured first at the BIPM for a period of about one month, then for a similar period at the NSAI-NML, and finally again at the BIPM.
The measurand was the 4 terminal dc resistance at low power.
The BIPM was the pilot laboratory, and the comparison forms part of the ongoing BIPM key comparisons BIPM.
EM-K13.
a (for 1 Ω) and BIPM.
EM-K13b (for 10 kΩ).
The results from the NSAI NML and the BIPM were found to be in good agreement, with a difference smaller than the relative expanded uncertainties (95% confidence, k = 2) of 0.
16 × 10-6 for 1 Ω and 0.
42 × 10-6 for 10 kΩ.
Main text
To reach the main text of this paper, click on Final Report.
Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.
bipm.
org/.
The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Related Results
Bilateral comparison of 10 V standards between the NSAI - NML (Ireland) and the BIPM (BIPM.EM-K11.b)
Bilateral comparison of 10 V standards between the NSAI - NML (Ireland) and the BIPM (BIPM.EM-K11.b)
As part of the ongoing BIPM key comparison BIPM.EM-K11.b, a comparison of the 10 V voltage reference standards of the BIPM and the National Standards Authority of Ireland - Nationa...
Bilateral comparison of 10 V standards between the NSAI-NML (Ireland) and the BIPM
Bilateral comparison of 10 V standards between the NSAI-NML (Ireland) and the BIPM
Main text
As part of the ongoing BIPM key comparison BIPM.EM-K11, a comparison of the 10 V voltage reference standards of the BIPM and the National Standards Auth...
Bilateral comparison of 10 V standards between the NSAI - NML (Ireland) and the BIPM, February 2016 (part of the ongoing BIPM key comparison BIPM.EM-K11.b)
Bilateral comparison of 10 V standards between the NSAI - NML (Ireland) and the BIPM, February 2016 (part of the ongoing BIPM key comparison BIPM.EM-K11.b)
As part of the ongoing BIPM key comparison BIPM.EM-K11.b, a comparison of the 10 V voltage reference standards of the BIPM and the National Standards Authority of Ireland - Nationa...
Bilateral comparison of 100 pF standards (ongoing BIPM key comparison BIPM.EM-K14.b) between the NSAI-NML (Ireland) and the BIPM
Bilateral comparison of 100 pF standards (ongoing BIPM key comparison BIPM.EM-K14.b) between the NSAI-NML (Ireland) and the BIPM
This report presents the results of a bilateral comparison of capacitance at 100 pF between the NSAI-NML (Ireland) and the BIPM carried out in 2016. This comparison forms part of t...
BIPM.EM-K11 comparison of 1.018 V and 10 V Standards between the BEV (Austria) and the BIPM, April to May 2025
BIPM.EM-K11 comparison of 1.018 V and 10 V Standards between the BEV (Austria) and the BIPM, April to May 2025
Main text
As part of the ongoing BIPM key comparison BIPM.EM-K11, a comparison of the 1.018 V and 10 V voltage reference standards of the BIPM and the Bundesamt für ...
Bilateral comparison of 10 pF and 100 pF standards (ongoing BIPM key comparisons BIPM.EM-K14.a and 14.b) between the NIMT (Thailand) and the BIPM
Bilateral comparison of 10 pF and 100 pF standards (ongoing BIPM key comparisons BIPM.EM-K14.a and 14.b) between the NIMT (Thailand) and the BIPM
This report presents the results of a bilateral comparison of 10 pF and 100 pF capacitance standards between the NIMT (Thailand) and the BIPM carried out in 2018. The comparison at...
Bilateral comparison of 1.018 V and 10 V standards between the BIM (Bulgaria) and the BIPM (BIPM.EM-K11.a and b)
Bilateral comparison of 1.018 V and 10 V standards between the BIM (Bulgaria) and the BIPM (BIPM.EM-K11.a and b)
Main text
As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1.018 V and 10 V voltage reference standards of the BIPM and the Bul...
Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Abstract
Introduction
Immunoglobulin G4-related disease (IgG4-RD) is a recently identified immune-mediated condition that is debilitating and often overlooked. While IgG4-RD has be...

